Introduction
Le journalTag TRED30-16R Temperature Logger is designed for precise temperature monitoring, especially for vaccine storage. It measures and stores up to 15,900 temperature readings within a range of -40°C to +99°C (-40°F to +210°F) using an external probe. The device features a display that indicates temperature excursions for the current day and the previous 29 days, along with current temperature, time, recording status, and battery status. It is VFC compliant and includes an audible alarm for out-of-range conditions.
Key features include simple setup and data download (requires LTI-USB Docking Station), CDC VFC compliance, versatile configuration for fridge or freezer environments, an audible alert system, and double assurance with a 2-year calibration certificate and a 2-year device warranty.

This image shows the LogTag TRED30-16R temperature data logger connected to an external probe, which is inserted into a glycol buffer bottle. The logger displays temperature readings and operational status.
Consignes de sécurité
Always handle the device with care. Do not expose the logger to extreme physical shock or moisture beyond its specified operating conditions. Ensure batteries are inserted correctly. Keep out of reach of children. This device is intended for professional use in monitoring temperature-sensitive products.
Contenu du colis
Lors du déballage, vérifiez que les éléments suivants sont inclus :
- EnregistrerTag TRED30-16R Data Logger
- 3” Stainless, 1/8”OD Probe with 5’ sensor cable (P/N SSP-0615)
- High Density plastic (shatter proof) glycol buffer bottle (P/N SPB1019)
- Acrylic stand (P/N AS1031)
- Installation/Mounting Kit (includes wall mounting bracket) (P/N IMK1015)
- Manuel d'instructions
- Battery (1 CR2032 battery required, may not be pre-installed)
- 2-Year NIST Traceable Certificate of Calibration (compliant to ISO/IEC 17025:2005)
Installation
- Installation de la batterie : Open the battery compartment and insert one CR2032 battery, observing polarity.
- Sonde de connexion : Securely connect the external temperature probe to the logger.
- Positionnement : Place the logger and the glycol buffer bottle with the probe inside the refrigerator or freezer. Use the acrylic stand and mounting kit as needed to ensure stable placement.
- Software & Docking Station: Le journalTag TRED30-16R requires an LTI-USB Docking Station (sold separately) and LogTag Analyzer software for initial configuration, starting, and downloading data. Install the LogTag Logiciel d'analyse sur votre ordinateur.
- Configuration initiale : Connect the logger to the LTI-USB Docking Station. Use the LogTag Analyzer software to configure logging parameters, alarm limits, and to specify whether the device is monitoring a fridge or freezer environment. This step is crucial for VFC compliance.
This video demonstrates the features and provides a 360-degree view du journalTag TRED30-16R Vaccine Monitoring Kit. It highlights the device's design, components, and key functionalities for tracking and recording temperature data.
Mode d'emploi
Démarrage d'une session d'enregistrement
- Connect the logger to the LTI-USB Docking Station.
- Use the LogTag Analyzer software to initiate a new recording session.
- Alternatively, if configured for button-start, press and hold the 'START CLEAR STOP' button until the 'REC' indicator appears on the display.
Comprendre l'affichage
- The display shows the current temperature, time, recording status (REC), and battery status.
- A checkmark (✓) indicates normal operation. An 'X' (✗) indicates an alarm condition.
- Day markers appear for days with temperature excursions.
Reviewing Marks
- Press the 'REVIEW MARK' button to cycle through recorded inspection marks or alarm events.
Suppression des alarmes
- If an alarm is triggered (indicated by 'X' and audible alert), press the 'START CLEAR STOP' button to silence the audible alarm and clear the alarm status indicator. The day marker will remain to indicate an excursion occurred.
Arrêter une session d'enregistrement
- Connect the logger to the LTI-USB Docking Station.
- Use the LogTag Analyzer software to stop the recording.
- Alternatively, if configured for button-stop, press and hold the 'START CLEAR STOP' button until the 'REC' indicator disappears.
Téléchargement de données
- Connect the logger to the LTI-USB Docking Station.
- Ouvrir le journalTag Analyzer software and follow the prompts to download the recorded temperature data for analysis and reporting.
Entretien
Remplacement de la batterie
When the battery status indicator shows low power, replace the CR2032 battery. Ensure the device is not actively recording before replacement.
Nettoyage
Wipe the device and probe with a soft, damp Chiffon. N’utilisez pas de nettoyants abrasifs et n’immergez pas l’appareil dans des liquides.
Étalonnage
The TRED30-16R comes with a 2-year NIST Traceable Certificate of Calibration. Regular re-calibration is recommended to ensure continued accuracy, especially for critical applications like vaccine monitoring. Contact LogTag or an authorized service provider for re-calibration services.
Dépannage
Device Not Starting/Recording
- Vérifiez l'installation et la charge de la batterie.
- Ensure the device is properly connected to the LTI-USB Docking Station and recognized by LogTag Logiciel d'analyse.
- Verify configuration settings in LogTag Analyseur.
Lectures de température inexactes
- Ensure the probe is correctly positioned within the glycol buffer bottle and the monitored environment.
- Vérifiez que la sonde et le câble ne présentent aucun dommage physique.
- Consider re-calibration if readings are consistently off compared to a known reference thermometer. Note that initial calibration accuracy can vary, and verification with reference thermometers is recommended.
Audible Alarm Not Sounding
- Check if the audible alarm feature is enabled in the LogTag Analyzer software configuration.
- Assurez-vous que la batterie est suffisamment chargée.
Data Download Issues
- Verify the LTI-USB Docking Station is correctly connected to the computer and the logger.
- Ensure LogTag Le logiciel d'analyse est à jour.
- Check USB port functionality.
Caractéristiques
| Modèle | VAC-TRED30-KIT-2 |
| Plage de mesure | -40°C à +99°C (-40°F à +210°F) |
| Capacité de mémoire | Jusqu'à 15,900 relevés de température |
| Précision de la température | ±1°C |
| Source d'énergie | Batterie 1 x CR2032 |
| Connectivité | USB (via LTI-USB Docking Station, sold separately) |
| Caractéristiques spéciales | Alarm, Temperature Monitor, VFC Compliant |
| Composants inclus | Data Logger, External Probe, Glycol Buffer Bottle, Acrylic Stand, Mounting Hardware, Instruction Manual, Calibration Certificate |
| Dimensions du colis | 7.09 x 5.12 x 2.13 pouces |
| Poids de l'article | 0.01 onces |
Informations sur la garantie
Le journalTag TRED30-16R Vaccine Monitoring Kit includes a 2-year device warranty from the date of purchase. This warranty covers manufacturing defects under normal use. For warranty claims, please contact your vendor or LogTag support with your proof of purchase.
Soutien
For further assistance, technical support, or information regarding LogTag Analyzer software, please refer to the official LogTag website or contact your product supplier. An LTI-USB Docking Station is required for full device functionality, including setup, data download, and advanced configuration.