Extech EX355

Extech EX355 True RMS Multimeter with Temperature Measurement Instruction Manual

Modèle: EX355

1. Introduction

This manual provides detailed instructions for the safe and effective operation of the Extech EX355 True RMS Multimeter. The EX355 is a professional digital multimeter designed for a wide range of electrical measurements, including AC/DC voltage, current, resistance, capacitance, frequency, duty cycle, and temperature. It features True RMS for accurate readings of non-sinusoidal waveforms, Non-Contact Voltage (NCV) detection for enhanced safety, Low Impedance (LoZ) mode to prevent ghost voltage readings, and a Low Pass Filter (LPF) for noise reduction in electrical environments.

Please read this manual thoroughly before using the device to ensure proper function and to prevent potential hazards.

2. Consignes de sécurité

Always adhere to the following safety precautions to avoid personal injury or damage to the multimeter:

3. Produit terminéview

The Extech EX355 is a versatile True RMS Multimeter equipped with several advanced features for accurate and safe electrical testing.

Caractéristiques principales :

Extech EX355 True RMS Multimeter

Figure 1: The Extech EX355 True RMS Multimeter. This image shows the front view of the multimeter, highlighting its display, rotary dial, function buttons, and input jacks.

4. Installation

4.1 Installation de la batterie

The Extech EX355 requires two (2) AA batteries for operation. These are typically included with the device.

  1. Assurez-vous que le multimètre est hors tension.
  2. Repérez le couvercle du compartiment à piles à l'arrière de l'appareil.
  3. Dévissez la ou les vis de fixation et retirez soigneusement le couvercle.
  4. Insérez deux piles AA en respectant la polarité correcte (+ et -) comme indiqué à l'intérieur du compartiment.
  5. Remettez le couvercle du compartiment à piles en place et fixez-le avec la ou les vis.

Note: Replace batteries immediately when the low battery indicator appears on the display to maintain measurement accuracy.

4.2 Connexion des cordons de test

Always connect the test leads correctly for the desired measurement function.

5. Mode d'emploi

This section details how to perform various measurements using the Extech EX355 multimeter.

5.1 Volume CA/CCtage Mesure

  1. Réglez le bouton rotatif sur V~ (AC Voltage) ou V- (DC Vol.tage) poste.
  2. Connectez le cordon de test rouge au VΩHzCAP Jack et le test noir mènent à COM jack.
  3. Appliquez les sondes de test sur les points du circuit où voltage doit être mesuré.
  4. Lire le voltage valeur sur l'affichage.

5.2 Mesure du courant alternatif/continu

Prudence: Ne jamais connecter le multimètre en parallèle avec un volumetagLors de la mesure du courant, connectez toujours la source en série avec la charge.

  1. Set the rotary dial to the appropriate A~ (Courant alternatif) ou A- (DC Current) range (e.g., 10A or mAµA).
  2. Connectez le cordon de test rouge au 10A or mAµA Jack et le test noir mènent à COM jack.
  3. Ouvrez le circuit où le courant doit être mesuré et connectez les sondes de test en série.
  4. Lisez la valeur actuelle affichée.

5.3 Mesure de résistance

Avertissement: Assurez-vous que le circuit est hors tension avant de mesurer la résistance.

  1. Réglez le bouton rotatif sur Ω (Position de résistance).
  2. Connectez le cordon de test rouge au VΩHzCAP Jack et le test noir mènent à COM jack.
  3. Placez les sondes de test en contact direct avec le composant ou le segment de circuit à mesurer.
  4. Lisez la valeur de résistance sur l'écran.

5.4 Mesure de capacité

Avertissement: Discharge capacitors before measuring to prevent damage to the meter.

  1. Réglez le bouton rotatif sur CAPUCHON (Capacité) position.
  2. Connectez le cordon de test rouge au VΩHzCAP Jack et le test noir mènent à COM jack.
  3. Mettez les sondes de test en contact avec les bornes du condensateur.
  4. Lire la valeur de capacité sur l'écran.

5.5 Mesure de la fréquence et du rapport cyclique

  1. Réglez le bouton rotatif sur hertz/% (Position de fréquence/cycle de service).
  2. Connectez le cordon de test rouge au VΩHzCAP Jack et le test noir mènent à COM jack.
  3. Mettez les sondes de test en contact avec la source du signal.
  4. Appuyez sur le hertz/% button to toggle between frequency and duty cycle readings.

5.6 Mesure de la température

The EX355 includes a general purpose bead wire temperature probe.

  1. Réglez le bouton rotatif sur Température (Température) position.
  2. Insert the temperature probe into the VΩHzCAP (positif) et COM (negative) jacks, observing polarity.
  3. Placez l'extrémité de la sonde de température sur ou dans l'objet à mesurer.
  4. Read the temperature value on the display. The unit can display in Celsius or Fahrenheit.
Man using Extech EX355 Multimeter for temperature measurement in an air vent

Figure 2: Using the Extech EX355 to measure temperature in an HVAC vent. The image shows a person holding the multimeter and inserting the temperature probe into an air conditioning vent.

5.7 volumes sans contacttage (NCV) Détection

NCV mode allows for quick detection of AC voltaget sans contact direct, ce qui renforce la sécurité.

  1. Réglez le bouton rotatif sur NCV position.
  2. Move the top of the multimeter near a conductor or outlet.
  3. The NCV indicator light will illuminate and an audible beep will sound if AC voltage is detected. The intensity of the beep and light may increase with stronger fields.

5.8 Mode basse impédance (LoZ)

LoZ mode helps eliminate false readings caused by ghost voltaget.

  1. Réglez le bouton rotatif sur LoZV position.
  2. Connect the test leads as for standard voltage mesure.
  3. The meter will present a low impedance load to the circuit, dissipating ghost voltages and providing a more accurate reading of actual voltage.

5.9 Filtre passe-bas (LPF)

The LPF function is used to filter out high-frequency noise, providing stable readings in variable frequency drive (VFD) applications or other noisy electrical environments.

  1. Set the rotary dial to an AC Voltaget (V~) or AC Current (A~) gamme.
  2. Appuyez sur le LPF button to activate the low pass filter. The LPF icon will appear on the display.
  3. Perform your measurement as usual. The meter will now display readings with high-frequency noise attenuated.
  4. Appuyez sur le LPF button again to deactivate the filter.
Extech EX355 Multimeter connected to an electrical control panel

Figure 3: The Extech EX355 Multimeter in use, connected to an electrical control panel. This image demonstrates the multimeter's application in industrial or commercial electrical diagnostics.

Extech EX355 Multimeter connected to a fuse box

Figure 4: The Extech EX355 Multimeter connected to a fuse box. This image illustrates the multimeter being used for testing within a residential or commercial electrical distribution system.

5.10 Data Hold, Min/Max, Relative Mode

5.11 Test de continuité et de diode

Avertissement: Ensure the circuit is de-energized before performing continuity or diode tests.

6. Entretien

6.1 Remplacement de la batterie

Refer to section 4.1 for detailed instructions on replacing the two AA batteries. Always use fresh, high-quality AA batteries.

6.2 Remplacement du fusible

If the current measurement functions cease to work, the fuse may need replacement. This procedure should only be performed by qualified personnel.

  1. Assurez-vous que le multimètre est éteint et que tous les cordons de test sont déconnectés.
  2. Retirez le couvercle du compartiment à piles et les piles.
  3. Unscrew the case screws and carefully separate the two halves of the meter casing.
  4. Locate the blown fuse(s). The EX355 typically uses two fuses: a 0.5A/600V fast-blow fuse for the mA/µA input and a 10A/600V fast-blow fuse for the 10A input.
  5. Replace the fuse(s) with fuses of the exact same type and rating. Never use a fuse with a different rating.
  6. Carefully reassemble the meter casing, ensuring all screws are tightened. Reinstall batteries and the battery cover.

6.3 Nettoyage et stockage

7. Dépannage

ProblèmeCause possibleSolution
Aucun affichage ou affichage faiblePiles mortes ou faiblesRemplacez les piles (voir section 4.1).
Lectures incorrectesIncorrect function/range selected; Damaged test leads; External interference; Blown fuse (for current)Verify function/range; Inspect/replace test leads; Move away from strong electromagnetic fields; Check/replace fuses (refer to Section 6.2).
Bip de continuitéOpen circuit; High resistance; Incorrect modeEnsure circuit is closed; Check for high resistance; Verify continuity mode is selected.
La mesure du courant ne fonctionne pas.Blown fuse; Incorrect lead connectionCheck and replace appropriate fuse (refer to Section 6.2); Ensure leads are in the correct current jacks.
NCV ne détecte pas le volumetagePas de vol ACtage present; Weak field; Incorrect modeVérifier le volume ACtage with direct contact method; Ensure NCV mode is selected; Move closer to the conductor.

8. Spécifications

The following table outlines the key specifications for the Extech EX355 True RMS Multimeter:

ParamètreValeur
Numéro de modèleEX355
Fonctions de mesureVol AC/DCtage, AC/DC Current, Resistance, Capacitance, Frequency, Duty Cycle, Temperature, Diode, Continuity
Valeur efficace vraieOui
Vol sans contacttage (PCI)Oui
Faible impédance (LoZ)Oui
Filtre passe-bas (LPF)Oui
Vol de fonctionnement maximaltage600 volts
Précision de mesure+/-0.5% (typical, varies by function/range)
AfficherÉcran LCD 4000 points
Source d'énergie2 piles AA (incluses)
Dimensions (L x l x H)8.1 x 4.8 x 17 cm (3.2 x 1.9 x 6.7 pouces)
Poids de l'article372 g (0.82 lb)
MatérielABS
CertificationIEC 61010-1, CE, CAT III 600V
Composants inclusTest leads, two AA batteries, general purpose bead wire temperature probe
Extech EX355 Multimeter with dimensions overlay

Figure 5: Extech EX355 Multimeter with approximate dimensions shown in inches and centimeters. This image provides a visual reference for the physical size of the device.

9. Informations sur la garantie

Extech provides a warranty for its products. Specific warranty terms and conditions, including duration and coverage, may vary by region and product. For detailed warranty information, please refer to the warranty card included with your product or visit the official Extech webConsultez le site. Conservez votre reçu d'achat comme preuve d'achat pour toute réclamation au titre de la garantie.

10. Assistance clientèle

For technical assistance, troubleshooting, or service inquiries regarding your Extech EX355 Multimeter, please contact Extech customer support. You can typically find contact information, including phone numbers and email addresses, on the official Extech websur le site ou dans la documentation fournie avec votre produit.

Ressources en ligne : Visit the official Extech website for FAQs, product downloads, and additional support resources.

Documents connexes - EX355

Préview Multimètres Extech : Guide complet des multimètres numériques et des testeurs d’isolation
Découvrez la gamme de multimètres numériques (DMM) et de testeurs d'isolation Extech, notamment les séries EX300, EX350, EX360, EX400, EX500, MM750W, MG320, MG325, DM220, MN35/36 et 381676A. Leurs fonctionnalités incluent la mesure de la valeur efficace vraie (True RMS), la tension sans contact (NCV), le filtre passe-bas (LPF), la mesure de l'impédance (LoZ), la mesure de la température et l'enregistrement de données sans fil.
Préview EXTECH MG320 Insulation Tester + DMM User Manual
User manual for the EXTECH MG320 True RMS Insulation Resistance CAT IV 600V DMM, covering features, safety, operating instructions, maintenance, and specifications.
Préview Extech 380801 & 380803 Power Analyzer Datalogger User's Guide
User's Guide for Extech 380801 and 380803 Power Analyzer Datalogger. Details features, specifications, basic operation, meter description, and warranty information for electrical power analysis.
Préview Extech DV30 AC VoltagManuel d'utilisation du détecteur e
Manuel d'utilisation du régulateur de tension Extech DV30 AC VoltagDétecteur électronique, détaillant les précautions de sécurité, le fonctionnement, les spécifications, le remplacement de la batterie, la mise au rebut, la garantie et les informations de contact.
Préview Manuel d'utilisation du multimètre Extech EX470A True RMS avec thermomètre infrarouge
Manuel d'utilisation complet du multimètre et thermomètre infrarouge Extech EX470A True RMS à sélection automatique de la gamme, couvrant la sécurité, le fonctionnement, les spécifications, la maintenance et les informations sur la garantie.
Préview Guide d'utilisation du multimètre de poche Extech DM100
Guide d'utilisation du multimètre de poche à sélection automatique de gamme Extech DM100 4000 points, couvrant la sécurité, les spécifications, le fonctionnement, les caractéristiques et l'entretien.