SIMPLEX 4099-9005

Simplex 4099-9005 Addressable Manual Pull Station (Dual Action) User Manual

Modèle: 4099-9005

1. Introduction

The Simplex 4099-9005 is an addressable manual pull station designed for use with compatible Simplex fire alarm control panels. This dual-action device requires two distinct operations to activate, reducing the likelihood of accidental activation. It is an integral component of a comprehensive fire detection and alarm system, providing a manual means for occupants to initiate an alarm in the event of a fire or other emergency.

2. Consignes de sécurité

Consignes de sécurité importantes :

3. Produit terminéview

The Simplex 4099-9005 is a red, dual-action manual pull station. Its addressable nature allows the fire alarm control panel to identify the exact location of the activated station. The dual-action design requires a two-step process for activation: first, pushing in a bar, and then pulling down a handle.

Devant view of the Simplex 4099-9005 Addressable Manual Pull Station, showing the 'FIRE ALARM' label, 'PUSH BAR', and 'PULL HANDLE'.

Figure 1 : Face avant view of the Simplex 4099-9005 Addressable Manual Pull Station. This image displays the primary components including the 'FIRE ALARM' text, the 'PUSH BAR' mechanism, and the 'PULL HANDLE' for activation.

4. Installation

Proper installation is crucial for the reliable operation of the manual pull station.

4.1 Montage

4.2 Câblage

4.3 Réglage de l'adresse

The 4099-9005 is an addressable device. Before connecting to the SLC, set the unique address for the pull station using the appropriate Simplex programming tool or DIP switches, as specified in the device's technical documentation. Each device on the SLC must have a unique address.

Côté view of the Simplex 4099-9005 Addressable Manual Pull Station, showing its depth and mounting points.

Figure 2 : Côté view of the Simplex 4099-9005 Addressable Manual Pull Station. This image illustrates the depth of the unit and provides a perspective on its mounting configuration.

5. Fonctionnement

5.1 Activation de l'alarme

In the event of a fire or emergency, follow these steps to activate the manual pull station:

  1. Pousser vers l'intérieur : Firmly push the bar labeled "PUSH BAR" on the front of the station.
  2. Tirer vers le bas: Once the bar is pushed in, pull down the handle labeled "PULL HANDLE" until it latches in the down position.

Activation will send an alarm signal to the fire alarm control panel, initiating the building's alarm sequence.

5.2 Réinitialisation de la station de traction

After an alarm has been activated and the emergency resolved, the pull station must be reset. The Simplex 4099-9005 requires a B-Key for resetting.

  1. Insert B-Key: Locate the keyhole on the front of the pull station. Insert the B-Key into the keyhole.
  2. Clé en main : Turn the B-Key clockwise or counter-clockwise (depending on the specific mechanism) to release the latched handle.
  3. Fermer la couverture : Return the handle to its original, unactivated position and close the front cover.
  4. Remove B-Key: Remove the B-Key.

The B-Key is considered a tool for maintenance and resetting, not a consumable item. If additional B-Keys are required, they can be ordered using PID: 252-019.

6. Entretien

Regular maintenance ensures the continued reliability of your Simplex 4099-9005 pull station.

7. Dépannage

If you encounter issues with your Simplex 4099-9005 pull station, consider the following:

For persistent issues, contact a qualified fire alarm technician.

8. Spécifications

FonctionnalitéSpécification
MarqueSIMPLEX
Numéro de modèle4099-9005
StyleSécurité
Source d'énergieManuel
Poids de l'article3.53 once (100 grammes)
Type d'alarmeAudible (via FACP)
MatérielGlass (referring to break-glass type, though this model is dual-action)
Dimensions du produit1 x 3.4 x 5 pouces
Code UPC643485652991
Numéro de pièceS4099-9005
Piles requisesNon

9. Informations sur la garantie

Specific warranty details for the Simplex 4099-9005 Addressable Manual Pull Station are typically provided at the point of purchase or can be obtained directly from Simplex or an authorized distributor. Please retain your proof of purchase for warranty claims. For detailed warranty terms and conditions, refer to the official Simplex documentation or contact their customer service.

10. Assistance clientèle

For technical assistance, installation queries, or service requests, please contact your authorized Simplex dealer or a certified fire alarm technician. Ensure you have the product model number (4099-9005) and any relevant system information available when seeking support.

Documents connexes - 4099-9005

Préview Déclencheurs d'alarme incendie manuels adressables Simplex IDNet/MAPNET II - Données produit
Informations détaillées sur les déclencheurs manuels d'alarme incendie adressables Simplex série 4099, compatibles avec les systèmes IDNet et MAPNET II. Caractéristiques, spécifications, options de montage et sélection de produits pour différents modèles, notamment à simple action, à double action (brise-verre et pression) et sans poignée. Conformes aux normes ADA et homologués UL, ULC, FM et CSFM.
Préview Stations manuelles adressables simplex : périphériques IDNet/MAPNET II
Découvrez les déclencheurs manuels d'alarme incendie adressables Simplex : leurs caractéristiques, leurs versions à simple ou double action, leurs options sans poignée et leur compatibilité avec les systèmes IDNet/MAPNET II. Informations de montage et spécifications incluses.
Préview Fiche technique des déclencheurs d'alarme incendie manuels à simple et double action Simplex série 2099
Fiche technique des déclencheurs manuels d'alarme incendie non codés et non adressables de la série Simplex 2099. Ce document présente les caractéristiques, les modes de fonctionnement, les références d'application, la sélection du produit, les options de montage et les spécifications.
Préview Simplex 4010ES : Systèmes de commande d'extinction automatique pour gicleurs
Guide technique Simplex 4010ES détaillant les modules de commande pour les systèmes d'extinction automatique par gicleurs, couvrant les modes déluge et préventif, avec spécifications, homologations et schémas de connexion.
Préview Simplex 4099-9801C IDNet™ 2-Stage Station IAM Installation Instructions
Installation instructions for the Simplex 4099-9801C IDNet™ 2-Stage Station Individual Addressable Module (IAM). Covers mechanical installation, electrical connections, and address configuration for fire alarm systems.
Préview Centrale d'alarme incendie Simplex 4004 : Instructions d'installation et d'utilisation
Guide complet d'installation, d'utilisation et de programmation du panneau de contrôle d'alarme incendie Simplex 4004 (FACP), incluant la configuration du système.view, exigences, câblage, descriptions des modules et dépannage.