Legrand LMRC-212

Legrand Watt Stopper LMRC-212 Digital 2-Relay Room Controller Instruction Manual

Model: LMRC-212

1. Introduction

This manual provides comprehensive instructions for the installation, operation, and maintenance of the Legrand Watt Stopper LMRC-212 Digital 2-Relay Room Controller. This device is designed for efficient lighting control in commercial and industrial applications, integrating occupancy sensors, daylighting controls, and switches within a Digital Lighting Management (DLM) system.

2. Consignes de sécurité

AVERTISSEMENT: Risk of electric shock. Installation and servicing must be performed by qualified personnel only. Disconnect power at the circuit breaker or fuse before installing or servicing. Follow all national and local electrical codes.

3. Produit terminéview

The LMRC-212 is a digital 2-relay room controller that serves as a foundational component of a Watt Stopper Digital Lighting Management (DLM) system. It features two relays for switching loads and two 0-10 volt outputs for dimmable loads, such as electronic ballasts. The device facilitates integration with various lighting control components via RJ-45 connectivity.

Caractéristiques principales :

Devant view of the Legrand Watt Stopper LMRC-212 Digital 2-Relay Room Controller

Figure 3.1 : Face avant view of the LMRC-212 controller.

Back label of the LMRC-212 controller showing product specifications and certifications

Figure 3.2: Product label on the LMRC-212 controller detailing electrical specifications and certifications.

4. Spécifications

FonctionnalitéDétail
Numéro de modèleLMRC-212
Vol d'entréetage120/277 VCA, 50 / 60Hz
Output Current (DLM)250 mA à 24 VCC
Maximum Load (Ballast/Incandescent)20 Amps
Charge du moteur1 HP @ 120VAC
Maximum Combined Load20 Amps
Dimming OutputsTwo 0-10V dimming outputs
ConnectivitéRJ-45
Type de montageSupport mural
Dimensions7.7 x 7.3 x 4.4 pouces
Poids1 livre
CertificationsUL 2043 Plenum Rated, cULus Listed

5. Installation et câblage

Before beginning installation, ensure that power to the circuit is disconnected at the main breaker. The LMRC-212 is designed for wall mounting and integrates into a Digital Lighting Management (DLM) network.

Connexions de câblage :

  1. Puissance d'entrée : Connect the 120/277V AC power supply to the designated terminals.
  2. Connexions de charge : Connect lighting loads to Load A and Load B terminals. The LMRC-212 supports two independent relays.
  3. 0-10V Dimming Outputs: Connect 0-10V dimmable ballasts or LED drivers to the respective 0-10V Dimming Output terminals (Violet + and Grey - for each load).
  4. DLM Network Connection: Connect the LMRC-212 to the DLM Local Network using an RJ-45 cable. Important: Connect only to a DLM Local Network, not to Ethernet.
Interne view of LMRC-212 controller showing wiring terminals for loads, dimming outputs, and RJ-45 ports

Figure 5.1: Internal wiring diagram of the LMRC-212, highlighting Load A, Load B, 0-10V Dimming Outputs, and RJ-45 DLM network ports.

Bouton de configuration :

The device includes a configuration button (labeled "Config") for initial setup and pairing with other DLM devices. Refer to the DLM system guide for detailed configuration procedures.

6. Fonctionnement

Once installed and configured within a DLM system, the LMRC-212 controls connected lighting loads based on inputs from DLM occupancy sensors, daylight sensors, and wall switches.

Manual Control (via connected DLM switches):

The specific behavior and grouping of loads are determined during the DLM system configuration process.

7. Entretien

The LMRC-212 is designed for long-term, reliable operation with minimal maintenance. Periodically inspect the device and its connections to ensure proper functioning.

8. Dépannage

If the LMRC-212 or connected lighting loads are not functioning as expected, perform the following basic troubleshooting steps:

For persistent issues, contact Legrand Watt Stopper technical support.

9. Garantie et assistance

For warranty information, please refer to the official Legrand Watt Stopper warranty statement available on their website or included with the product packaging. For technical assistance, product support, or to report issues, please contact:

Watt Stopper Technical Support:
Téléphone: 800.879.8585
Website: www.wattstopper.com

Documents connexes - LMRC-212

Préview Guide de démarrage rapide du contrôleur de pièce Wattstopper LMRC-111/112 DLM
Guide de démarrage rapide pour les contrôleurs d'éclairage Wattstopper DLM à relais simple/double (LMRC-111, LMRC-112) avec variation d'intensité 0-10 V. Ce guide couvre l'installation, le câblage, la mise en service rapide (Plug & Go) et la sécurité des systèmes de contrôle d'éclairage.
Préview Legrand Wattstopper Digital Lighting Management (DLM) Product Guide
Comprehensive product guide for Legrand Wattstopper Digital Lighting Management (DLM) systems, detailing solutions for room controls, network controls, integration, services, personal controls, occupancy sensors, daylight sensors, load controllers, interface devices, fixture controls, configuration tools, network components, lighting control panels, enclosures, and accessories.
Préview Wattstopper FSP-311: Continuous Dimming PIR Motion Sensor with Bluetooth - Installation Guide
Comprehensive guide for the Wattstopper FSP-311, a line voltage PIR fixture-integrated sensor with Bluetooth. Covers installation, operation, specifications, app configuration, troubleshooting, and ordering information for continuous dimming lighting control.
Préview Instructions d'installation du capteur de luminosité intégré Wattstopper FD-301
Guide d'installation et d'utilisation du capteur de luminosité intégré Wattstopper FD-301 de Legrand, qui contrôle les ballasts à gradation 0-10 V CC en fonction de la luminosité naturelle. Ce guide inclut les spécifications, la configuration, l'installation, le câblage et le dépannage.
Préview Relais de verrouillage connecté Legrand 4 121 70 - Guide d'installation et d'utilisation
Guide complet d'installation et d'utilisation du relais de verrouillage connecté Legrand (modèle 4 121 70). Découvrez le câblage, l'intégration à l'application, la commande manuelle et le dépannage.
Préview Legrand UXOne Hotel System: Hotel Room Supervision User Manual
Comprehensive user manual for the Legrand UXOne Hotel System, detailing how to supervise and manage hotel rooms, control room settings, and configure user access. Includes instructions for operation and system management.