1. Introduction

The QuietWarmth THERMST-D Non-Programmable Thermostat is designed to provide reliable control for 120V or 240V electric radiant floor heating systems. This thermostat offers flexible temperature management, allowing you to configure it for control based on floor temperature, room temperature, or a combination of room temperature with a floor temperature limit. It features a built-in Ground Fault Circuit Interrupter (GFCI) for enhanced safety and a clear, backlit display for easy monitoring and operation. A floor sensor is included to ensure accurate temperature readings and optimal comfort.

Devant view of the QuietWarmth THERMST-D Non-Programmable Thermostat, showing the digital display and control buttons.

Figure 1 : Face avant view of the THERMST-D Thermostat.

2. Consignes de sécurité

Please read all instructions carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or property damage.

  • AVERTISSEMENT: To reduce the risk of electric shock, do not connect this device to a circuit with any phase operating down more than 150 volts to ground.
  • L'installation doit être effectuée par un électricien qualifié, conformément aux normes électriques locales et nationales.
  • The thermostat requires connection to a dedicated 20 Amp circuit.
  • The resistive load connected to the thermostat must not exceed 15 Amps.
  • Electric radiant floor heating systems are required by the National Electrical Code to be protected by a Ground Fault Circuit Interrupter (GFCI). This thermostat has a built-in GFCI.
  • Coupez toujours l'alimentation au niveau du disjoncteur avant d'installer ou d'entretenir le thermostat.
Côté view of the QuietWarmth THERMST-D Thermostat showing a warning label regarding electric shock risk.

Figure 2 : Côté view of the thermostat with safety warning label.

3. Contenu du colis

Vérifiez que tous les éléments sont présents dans le colis :

  • QuietWarmth THERMST-D Non-Programmable Thermostat
  • Capteur de sol

4. Produit terminéview

4.1 Principales caractéristiques

  • Non-Programmable operation for radiant floor heat systems.
  • Compatible with both 120V and 240V heating systems.
  • Integrated Ground Fault Circuit Interrupter (GFCI) for safety.
  • Clear, backlit LED display for easy reading.
  • Includes a floor sensor for precise temperature control.
  • Configurable for floor temperature, room temperature, or room temperature with a floor temperature limit.
  • Seven-day energy log to monitor power consumption.
  • Supports multiple QuietWarmth mats: up to 120 sq ft for 120V systems, or 240 sq ft for 240V systems.

4.2 Composants

The thermostat consists of a front display unit with control buttons and a back plate for electrical connections.

  • Panneau avant : Features a digital display showing time and temperature, along with 'Up', 'OK', and 'Down' buttons for navigation and setting adjustments.
  • Panneau arrière: Contains wiring terminals for power input (L1, L2) and load output, as well as a connection point for the floor sensor.
Dos view of the QuietWarmth THERMST-D Thermostat showing wiring terminals labeled L1(L), L2(N), and Load, along with a mounting screw.

Figure 3 : Retour view of the thermostat with wiring terminals.

Image of the QuietWarmth floor sensor, a black cable with a small probe at the end.

Figure 4: Included floor sensor.

5. Configuration et installation

L'installation doit être effectuée uniquement par un électricien qualifié.

5.1 Montage

  • The thermostat is designed for wall mounting.
  • Ensure the mounting location is free from direct sunlight, drafts, or other heat sources that could affect temperature readings.

5.2 Câblage

Before wiring, ensure power is OFF at the circuit breaker.

  1. Connect the thermostat to a dedicated 20 Amp circuit.
  2. Identify the Line (power supply) and Load (heating mat) wires.
  3. Connect the Line wires to the L1(L) and L2(N) terminals on the thermostat's back panel.
  4. Connect the Load wires from the heating mat to the 'Load' terminals on the thermostat.
  5. Assurez-vous d'une mise à la terre correcte conformément aux normes électriques locales.
  6. The thermostat is dual-voltage; it can be used with either 120V or 240V heating mats, but not simultaneously. Verify your heating mat's voltage correspond à l'alimentation.

5.3 Floor Sensor Placement

The floor sensor is crucial for accurate floor temperature control.

  • Place the sensor next to the long edge of the QuietWarmth heating mat.
  • Ensure the sensor is positioned in the heated area and not near any unheated zones or external heat sources.
  • Route the sensor wire carefully to avoid damage during installation of flooring materials.
An illustration showing a golden retriever dog sleeping on a floor with radiant heat film installed underneath, indicating warmth for floating floors.

Figure 5 : Example of radiant heat film installation under floating floors.

An illustration showing a French bulldog puppy sleeping on a floor with radiant heat film installed underneath, indicating warmth for tile and glued floors.

Figure 6 : Example of radiant heat film installation under tile and glued floors.

6. Mode d'emploi

6.1 Mise sous tension

After installation, restore power at the circuit breaker. The thermostat display will illuminate.

6.2 Réglage de la température

  • Utilisez le Up et Vers le bas boutons pour régler la température désirée.
  • Appuyez sur le OK bouton pour confirmer votre sélection.

Modes de contrôle 6.3

The thermostat can be configured to operate in one of three control modes:

  • Floor Temperature Control: The thermostat maintains the floor at the set temperature using the floor sensor.
  • Contrôle de la température ambiante : The thermostat maintains the room air temperature at the set point.
  • Room Temperature Control with Floor Limit: The thermostat primarily controls room air temperature but prevents the floor temperature from exceeding a specified maximum limit, protecting sensitive flooring materials.

Refer to the full installation guide for instructions on how to select and configure these control modes.

6.4 Energy Log

The thermostat features a seven-day energy log, allowing you to monitor the power consumption of your radiant heating system. Consult the detailed manual for accessing and interpreting this data.

7. Entretien

7.1 GFCI Testing

For continued safety, the built-in GFCI should be tested monthly.

  1. Appuyez sur le TEST button located on the bottom of the thermostat.
  2. The GFCI should trip, cutting power to the heating system and indicating a fault.
  3. Appuyez sur le RÉINITIALISER button to restore power.
  4. If the GFCI does not trip or reset correctly, discontinue use and contact a qualified electrician.
Bas view of the QuietWarmth THERMST-D Thermostat showing the GFCI test button and 'Test Monthly' text.

Figure 7: Bottom of the thermostat with GFCI test button.

7.2 Nettoyage

Essuyez l'extérieur du thermostat avec un chiffon doux et sec.amp chiffon. N'utilisez pas de nettoyants abrasifs ou de solvants.

8. Dépannage

If you encounter issues with your QuietWarmth THERMST-D thermostat, refer to the following common problems and solutions:

  • Pas d'affichage/Pas d'alimentation :
    • Check the circuit breaker for the dedicated circuit and ensure it is in the ON position.
    • Vérifiez que tous les branchements électriques sont bien fixés et corrects.
  • Système de chauffage non activé :
    • Ensure the thermostat is set to a temperature higher than the current room or floor temperature.
    • Check if the GFCI has tripped (press the RESET button if it has).
    • Confirm the correct control mode is selected (floor, room, or room with limit).
  • GFCI Trips Frequently:
    • This indicates a ground fault. Immediately turn off power at the circuit breaker.
    • Inspect the heating mat and wiring for any damage or moisture.
    • Ensure the total resistive load does not exceed 15 Amps.
    • Contactez un électricien qualifié pour le diagnostic et la réparation.
  • Relevés de température inexacts :
    • Verify the floor sensor is correctly installed and not damaged.
    • Ensure the thermostat is not exposed to drafts, direct sunlight, or other external heat sources.

For issues not covered here, please contact QuietWarmth customer support or a qualified electrician.

9. Spécifications

SpécificationDétail
MarqueCalmeChaleur
Nom du modèleQuietWarmth Non-Programmable Thermostat
Numéro de pièceTHERMST-D
Dimensions du produit3"P x 4"L x 6"H
Poids de l'article11.4 onces
CouleurBlanc
MatérielPlastique
Voltage120 volts, 240 volts
Charge résistive maximale15 Amps
Source d'énergieCâblé
Type de contrôleurBouton poussoir
Type de contrôle de températureManuel
Type d'affichageLED (rétroéclairée)
Technologie de connectivitéCâblé
Dossier spécialEnergy Usage Tracking, Built-in GFCI
Type de montageSupport mural
Spécification satisfaiteUL
Code UPC696087109103

10. Garantie et assistance

10.1 Informations sur la garantie

The QuietWarmth THERMST-D Non-Programmable Thermostat comes with a 3-year limited warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use. Please retain your proof of purchase for warranty claims.

10.2 Assistance clientèle

For technical assistance, troubleshooting, or warranty inquiries, please contact QuietWarmth customer support. Refer to the product packaging or the manufacturer's website pour les informations de contact actuelles.