SDC 1091AIV

SDC 1091AIV SpaceSaver Electric Bolt Lock

Manuel d'instructions

Model: 1091AIV

1. Produit terminéview

The SDC 1091AIV SpaceSaver Electric Bolt Lock is an advanced locking solution designed for access control applications. Its unique design allows the stainless steel bolt to project at right angles to the lock mechanism, facilitating installation in standard 1.75-inch frames or most door lock stiles with a simple cutout. This concealed installation enhances both aesthetics and security.

Caractéristiques principales :

  • Adjustable auto relock switch
  • Fits 1-3/4-inches minimum face frames
  • Failsafe - 12/24VDC standard operation
  • Failsecure - choice of 12 or 24VDC operation
  • Aluminum finish standard
SDC 1091AIV SpaceSaver Electric Bolt Lock

Image 1: The SDC 1091AIV SpaceSaver Electric Bolt Lock, showcasing its narrow profile and bolt mechanism, alongside its strike plate.

2. Consignes de sécurité

Please read and understand all instructions before installation and operation. Failure to follow these instructions may result in product damage, property damage, or personal injury.

  • Installation professionnelle : Installation of this electric bolt lock should be performed by qualified personnel familiar with electrical systems and door hardware.
  • Sécurité électrique : Ensure power is disconnected before performing any wiring or maintenance. Verify correct voltage (12VDC or 24VDC) is supplied to prevent damage to the unit.
  • VoltagCompatibilité : This unit operates on 12VDC or 24VDC. Connecting to an incorrect voltage source will damage the lock.
  • Homologation UL : This product is UL listed and UL 10C positive pressure compliant. Adhere to all local building codes and regulations during installation.

3. Configuration et installation

3.1 Liste de contrôle de pré-installation

  • Verify door frame material and dimensions. A minimum 1-3/4 inch frame is required.
  • Ensure appropriate power supply (12VDC or 24VDC) is available.
  • Gather necessary tools: measuring tape, drill, appropriate drill bits, screwdriver set, wiring tools.

3.2 Montage du verrou

  1. Carefully measure and mark the desired location for the lock body and strike plate on the door frame and door edge, respectively.
  2. Create the necessary cutout in the door frame for the lock body. The SpaceSaver design allows for a simple cutout.
  3. Secure the lock body into the cutout using the provided fasteners. Ensure it is flush with the frame surface for proper operation and aesthetics.
  4. Install the strike plate on the door edge, aligning it precisely with the bolt mechanism of the lock.

3.3 Câblage

The SDC 1091AIV supports both Failsafe and Failsecure configurations. Determine the required operation before wiring.

  • Failsafe Operation: The lock will unlock when power is removed. This is typically used for egress doors where safety requires the door to open during a power failure. Connect the power supply according to the Failsafe wiring diagram provided with the product packaging.
  • Failsecure Operation: The lock will remain locked when power is removed. This is typically used for security applications where the door must remain secured during a power failure. Connect the power supply according to the Failsecure wiring diagram provided with the product packaging.
  • Assurez-vous que toutes les connexions électriques sont sécurisées et isolées pour éviter les courts-circuits.

3.4 Ajustements

The lock features an adjustable auto relock switch. Refer to the detailed instructions in the product packaging for specific adjustment procedures to fine-tune the relock timing.

4. Mode d'emploi

The SDC 1091AIV Electric Bolt Lock operates in conjunction with an access control system or a simple switch, depending on the installation configuration.

  • To Unlock (Failsafe): Apply power to the lock. The bolt will retract, allowing the door to open. Removing power will cause the bolt to extend, locking the door.
  • To Unlock (Failsecure): Remove power from the lock. The bolt will retract, allowing the door to open. Applying power will cause the bolt to extend, locking the door.
  • The adjustable auto relock switch will automatically extend the bolt after a set delay once the door is closed and aligned with the strike plate.

5. Entretien

Regular maintenance ensures optimal performance and longevity of your SDC 1091AIV Electric Bolt Lock.

  • Inspection: Periodically inspect the lock body, bolt, and strike plate for any signs of wear, damage, or misalignment. Ensure all fasteners are tight.
  • Nettoyage: Clean the exterior surfaces with a soft, dry cloth. Avoid using abrasive cleaners, solvents, or harsh chemicals, as these can damage the finish.
  • Lubrification: If the bolt mechanism appears stiff or noisy, a small amount of silicone-based lubricant can be applied to the moving parts. Do not over-lubricate.
  • Vérification du câblage : Annually, inspect wiring connections for any signs of corrosion or loose terminals.

6. Dépannage

If you encounter issues with your SDC 1091AIV Electric Bolt Lock, refer to the following troubleshooting guide:

ProblèmeCause possibleSolution
Lock not engaging/disengagingNo power, incorrect wiring, bolt obstruction, misalignment.Check power supply, verify wiring against diagram, ensure no physical obstructions, adjust lock/strike plate alignment.
Fonctionnement intermittentLoose wiring connections, fluctuating power supply, worn components.Secure all wiring connections, test power supply stability, inspect for wear.
Bruit excessif pendant le fonctionnementLack of lubrication, mechanical interference, worn parts.Apply a small amount of silicone lubricant to moving parts, check for obstructions, consider professional inspection if noise persists.
Auto relock not functioningIncorrect adjustment, sensor issue, door not closing properly.Adjust the auto relock switch settings, ensure the door closes fully and aligns with the strike plate.

If troubleshooting steps do not resolve the issue, contact SDC technical support or a qualified technician.

7. Spécifications

FonctionnalitéDétail
MarqueDDC
Nom du modèleÉconomiseur d'espace
Numéro de pièce1091AIV
Type de serrureElectric Mortise Lock
MatérielAluminium
CouleurAcier inoxydable
Source d'énergieDC (12VDC / 24VDC)
Dossier spécialSerrure à clé
Poids de l'article1.45 livres
Dimensions du colis10.8 x 3.4 x 2.4 pouces
Minimum Frame Fit1-3/4 pouces
Méthode de contrôleApp (as per product specifications, verify compatibility with specific access control systems)
CertificationsUL Listed, UL 10C Positive Pressure Compliant

8. Garantie et assistance

For specific warranty information regarding your SDC 1091AIV SpaceSaver Electric Bolt Lock, please refer to the documentation included with your purchase or contact the seller or manufacturer directly.

For technical assistance, installation support, or to report any issues, please contact SDC customer service through their official weble site ou les coordonnées fournies au moment de l'achat.

Documents connexes - 1091AIV

Préview Guide d'installation de la serrure à pêne dormant dissimulée extra-étroite SDC 1490AI Failsafe
Instructions d'installation détaillées pour la serrure à pêne dormant dissimulée extra-étroite SDC 1490AI Failsafe, y compris les schémas de câblage, les spécifications techniques et les conseils de dépannage.
Préview Instructions d'installation de la serrure à mortaiser dissimulée extra étroite SDC 2490AH Failsecure
Guide d'installation complet pour la serrure à mortaise dissimulée SDC 2490AH, couvrant le montage en hauteur et sur le montant latéral, les configurations de câblage avec et sans le régulateur de puissance PR-1000, le dépannage et les références dimensionnelles.
Préview Instructions d'installation de la serrure à mortaiser dissimulée à sécurité positive SDC 1291AHWD
Ce document fournit des instructions d'installation détaillées pour la serrure à mortaiser dissimulée à sécurité positive SDC 1291AHWD, incluant les procédures de montage horizontal et vertical, les schémas de câblage, les spécifications électriques et les conseils de dépannage. Il traite également de l'utilisation du régulateur de puissance PR-1000 et de l'interrupteur ARS.
Préview SDC 1190AIWD Fail-Safe Concealed Mortise Bolt Lock Installation Guide
Comprehensive installation instructions for the SDC 1190AIWD Fail-Safe Concealed Mortise Bolt Lock, including wiring diagrams, technical specifications, and troubleshooting tips.
Préview SDC 1091AI/1091AIDL Fail-Safe Concealed Mortise Bolt Lock Installation Instructions
Comprehensive installation guide for the SDC 1091AI and 1091AIDL fail-safe concealed mortise bolt locks. Includes step-by-step instructions for overhead and sidejamb mounting, wiring diagrams, troubleshooting, and technical specifications.
Préview Instructions d'installation de la serrure à mortaiser dissimulée à sécurité positive SDC 1291AH
Comprehensive installation guide for the SDC 1291AH Fail-Secure Concealed Mortise Bolt Lock. Covers overhead and sidejamb installation, wiring configurations with and without the PR-1000 Power Regulator, troubleshooting tips, and detailed technical specifications for metal doors and frames.