1. Introduction
The Detex EAX-500 Exit Alarm is a robust and reliable security device designed to provide audible alerts when an emergency exit door is opened. This manual provides essential information for the proper installation, operation, and maintenance of your EAX-500 unit to ensure optimal performance and security.
Image 1.1: The Detex EAX-500 Exit Alarm. This image displays the main unit, which is black, featuring a prominent red push bar for emergency exit. The unit is designed for surface mounting on a door.
2. Consignes de sécurité
Please read and understand all safety instructions before installing or operating the Detex EAX-500 Exit Alarm. Failure to follow these instructions may result in property damage or injury.
- Ensure the unit is installed by qualified personnel in accordance with local building codes and regulations.
- Coupez toujours l'alimentation électrique avant d'effectuer toute opération de maintenance ou d'entretien.
- N'exposez pas l'appareil à des températures ou à l'humidité extrêmes.
- Utilisez uniquement la pile 9V spécifiée pour l'alimentation.
- Conserver les matériaux d’emballage hors de portée des enfants.
3. Contenu du colis
À l'ouverture du colis, vérifiez que tous les composants sont présents :
- Detex EAX-500 Exit Alarm Unit (Black)
- Matériel de montage
- Manuel d'instructions
Note: The 9V battery and the On/Off mortise cylinder are sold separately and are required for full functionality.
4. Configuration et installation
Follow these steps for proper installation of the EAX-500 Exit Alarm:
- Préparez la porte : Identify the desired mounting location on the door. The unit is designed to mount directly on the door surface.
- Montez l'unité : Secure the EAX-500 unit to the door using the provided mounting hardware. Ensure it is level and firmly attached.
- Install the Mount Tab: Attach the mount tab to the door frame, aligning it with the unit on the door. This tab interacts with the alarm mechanism when the door is opened.
- Insérer la batterie : Open the battery compartment (typically located on the side or back of the unit). Insert a fresh 9V battery, ensuring correct polarity. Close the compartment securely.
- Install Mortise Cylinder: If using the arm/disarm feature, install the separately purchased mortise cylinder into the designated slot on the unit. Refer to the cylinder manufacturer's instructions for specific installation details.
- Fonctionnalité de test : After installation, perform a functional test to ensure the alarm activates correctly when the door is opened and can be armed/disarmed with the mortise cylinder.
5. Fonctionnement
The Detex EAX-500 Exit Alarm operates as follows:
- Armement de l'alarme : Insert the key into the mortise cylinder and turn it to the 'Armed' position. The unit is now ready to detect unauthorized door openings.
- Désarmer l'alarme : Insert the key into the mortise cylinder and turn it to the 'Disarmed' position. This will silence the alarm if it is sounding or prevent it from activating when the door is opened.
- Activation de l'alarme : When the door is opened while the alarm is armed, the mount tab on the door frame will disengage from the unit, triggering a loud audible alarm.
- Désactivation de l'alarme : To silence an activated alarm, disarm the unit using the mortise cylinder key.
6. Entretien
Regular maintenance ensures the longevity and reliability of your EAX-500 Exit Alarm.
- Remplacement de la batterie : The EAX-500 operates on a 9V battery. Replace the battery annually or immediately if the low battery indicator (if present) activates, or if the alarm sound becomes weak. To replace, open the battery compartment, remove the old battery, insert a new 9V battery with correct polarity, and close the compartment.
- Nettoyage: Clean the exterior of the unit with a soft, dry cloth. Do not use abrasive cleaners or solvents, as these can damage the finish or internal components.
- Tests fonctionnels : Periodically test the alarm's functionality by arming and opening the door to ensure it sounds correctly. This helps confirm the battery and mechanism are in working order.
7. Dépannage
Consultez le tableau suivant pour connaître les problèmes courants et leurs solutions :
| Problème | Cause possible | Solution |
|---|---|---|
| Alarm does not sound when door opens. | Battery is dead or low. Unit is disarmed. Mount tab not engaging properly. | Replace 9V battery. Ensure unit is armed. Adjust mount tab alignment. |
| L'alarme sonne en continu. | Unit is armed and door is not fully closed, or mount tab is misaligned. | Ensure door is fully closed. Disarm the unit. Check and adjust mount tab alignment. |
| Key does not turn in mortise cylinder. | Incorrect key. Cylinder is jammed. | Ensure you are using the correct key for the installed mortise cylinder. Consult a locksmith if cylinder is jammed. |
8. Spécifications
| Fonctionnalité | Détail |
|---|---|
| Marque | Détex |
| Numéro de modèle | EAX-500 |
| Source d'énergie | 9V Battery (sold separately) |
| Poids de l'article | 5 livres |
| Couleur | Noir |
| Code UPC | 033587104113 |
| Arm/Disarm Mechanism | Mortise Cylinder (sold separately) |
9. Informations sur la garantie
Specific warranty details for the Detex EAX-500 Exit Alarm are not provided in this manual. For information regarding warranty coverage, terms, and conditions, please refer to the documentation included with your purchase or visit the official Detex website.
10. Assistance clientèle
If you require further assistance, technical support, or have questions not covered in this manual, please contact Detex customer service. Contact information can typically be found on the Detex official website ou sur l'emballage du produit.