1. Introduction

The Detex EAX-500 Exit Alarm is a robust and reliable security device designed to provide audible alerts when an emergency exit door is opened. This manual provides essential information for the proper installation, operation, and maintenance of your EAX-500 unit to ensure optimal performance and security.

Detex EAX-500 Exit Alarm, black unit with a red push bar

Image 1.1: The Detex EAX-500 Exit Alarm. This image displays the main unit, which is black, featuring a prominent red push bar for emergency exit. The unit is designed for surface mounting on a door.

2. Consignes de sécurité

Please read and understand all safety instructions before installing or operating the Detex EAX-500 Exit Alarm. Failure to follow these instructions may result in property damage or injury.

3. Contenu du colis

À l'ouverture du colis, vérifiez que tous les composants sont présents :

Note: The 9V battery and the On/Off mortise cylinder are sold separately and are required for full functionality.

4. Configuration et installation

Follow these steps for proper installation of the EAX-500 Exit Alarm:

  1. Préparez la porte : Identify the desired mounting location on the door. The unit is designed to mount directly on the door surface.
  2. Montez l'unité : Secure the EAX-500 unit to the door using the provided mounting hardware. Ensure it is level and firmly attached.
  3. Install the Mount Tab: Attach the mount tab to the door frame, aligning it with the unit on the door. This tab interacts with the alarm mechanism when the door is opened.
  4. Insérer la batterie : Open the battery compartment (typically located on the side or back of the unit). Insert a fresh 9V battery, ensuring correct polarity. Close the compartment securely.
  5. Install Mortise Cylinder: If using the arm/disarm feature, install the separately purchased mortise cylinder into the designated slot on the unit. Refer to the cylinder manufacturer's instructions for specific installation details.
  6. Fonctionnalité de test : After installation, perform a functional test to ensure the alarm activates correctly when the door is opened and can be armed/disarmed with the mortise cylinder.

5. Fonctionnement

The Detex EAX-500 Exit Alarm operates as follows:

6. Entretien

Regular maintenance ensures the longevity and reliability of your EAX-500 Exit Alarm.

7. Dépannage

Consultez le tableau suivant pour connaître les problèmes courants et leurs solutions :

Problème Cause possible Solution
Alarm does not sound when door opens. Battery is dead or low. Unit is disarmed. Mount tab not engaging properly. Replace 9V battery. Ensure unit is armed. Adjust mount tab alignment.
L'alarme sonne en continu. Unit is armed and door is not fully closed, or mount tab is misaligned. Ensure door is fully closed. Disarm the unit. Check and adjust mount tab alignment.
Key does not turn in mortise cylinder. Incorrect key. Cylinder is jammed. Ensure you are using the correct key for the installed mortise cylinder. Consult a locksmith if cylinder is jammed.

8. Spécifications

Fonctionnalité Détail
Marque Détex
Numéro de modèle EAX-500
Source d'énergie 9V Battery (sold separately)
Poids de l'article 5 livres
Couleur Noir
Code UPC 033587104113
Arm/Disarm Mechanism Mortise Cylinder (sold separately)

9. Informations sur la garantie

Specific warranty details for the Detex EAX-500 Exit Alarm are not provided in this manual. For information regarding warranty coverage, terms, and conditions, please refer to the documentation included with your purchase or visit the official Detex website.

10. Assistance clientèle

If you require further assistance, technical support, or have questions not covered in this manual, please contact Detex customer service. Contact information can typically be found on the Detex official website ou sur l'emballage du produit.

Documents connexes - EAX-500

Préview Instructions d'installation de l'alarme de sortie Detex EAX-500
Guide d'installation complet pour l'alarme de sortie Detex série EAX-500, couvrant la configuration, le câblage, le fonctionnement et le dépannage des portes sécurisées. Inclut un schéma des pièces, la liste des accessoires et des instructions étape par étape.
Préview Instructions d'installation de l'alarme de sortie Detex EAX-500
Guide d'installation complet pour l'alarme de sortie Detex EAX-500 : configuration, câblage, dépannage et options pour portes sécurisées. Comprend un schéma des pièces, la liste des accessoires et les instructions étape par étape.
Préview Instructions d'installation du support de porte/carillon Detex EAX-300
Guide d'installation complet pour le support de porte et le carillon de porte Detex EAX-300, couvrant la répartition des pièces, le matériel, les procédures de montage, le câblage et le dépannage.
Préview Instructions d'installation du support de porte et du carillon Detex EAX-300
Guide d'installation complet pour les dispositifs d'alarme de porte et de carillon de porte de la série Detex EAX-300, couvrant la configuration, le câblage, le fonctionnement et le dépannage.
Préview Modèles Detex Value Series EB, EA, EX et EBxW : Instructions et guide électriques
Instructions électriques complètes, détails de fonctionnement, répartition des pièces, schémas de câblage et conseils de dépannage pour les dispositifs d'alarme de sortie Detex Value Series EB, EA, EX et EBxW.
Préview Instructions de câblage des alarmes à distance DETEX CS900/CS2900
Instructions de câblage détaillées pour les alarmes à distance des séries DETEX CS900 (CC uniquement, batterie 9 V) et CS2900 (alimentation externe avec batterie de secours), y compris les fonctions du bornier, les tailles de fil recommandées et les conseils d'installation.