Buderus WK 7300-00.500

Manuel d'utilisation de la tête thermostatique Buderus WK 7300-00.500

1. Introduction

This manual provides essential information for the proper installation, operation, and maintenance of your Buderus WK 7300-00.500 Thermostatic Head. Please read these instructions carefully before installation and retain them for future reference. Correct use ensures optimal performance and longevity of the product.

2. Produit terminéview

The Buderus WK 7300-00.500 is an angled thermostatic head designed for precise temperature control in rooms equipped with radiators. It features a liquid-filled sensor for stable and accurate regulation of room temperature by controlling the flow of hot water through the radiator.

Caractéristiques principales :

  • Conception angulaire : Optimized for mounting on radiators with an M30 x 1.5 threaded connection.
  • Capteur intégré : Ensures accurate temperature detection and control.
  • Montage réversible : Can be installed on either the left or right side of the radiator valve.
  • Liquid-Filled Thermostat: Provides stable and responsive control behavior.
  • White Scale Cover: Clear and easy-to-read temperature settings.
Buderus WK 7300-00.500 Thermostatic Head
Devant view of the Buderus WK 7300-00.500 Thermostatic Head, showing the numbered scale, temperature symbols, and the M30x1.5 connection.

3. Configuration et installation

La sécurité avant tout : Before beginning installation, ensure the heating system is depressurized and cooled down to prevent injury from hot water or steam. If you are unsure about any steps, consult a qualified heating technician.

Étapes d'installation :

  1. Préparer le robinet du radiateur : Ensure the existing thermostatic valve body on your radiator has an M30 x 1.5 threaded connection.
  2. Retirer l'ancienne tête (le cas échéant) : If replacing an old thermostatic head, carefully unscrew it from the valve body.
  3. Position the Thermostatic Head: Place the Buderus WK 7300-00.500 onto the valve body. The head is reversible, allowing for left or right mounting to suit your radiator's orientation.
  4. Sécurisez la tête : Hand-tighten the threaded ring of the thermostatic head onto the M30 x 1.5 connection of the valve body until it is firm. Do not overtighten.
  5. Vérifiez la stabilité : Ensure the head is securely attached and does not wobble.
Technical drawing of Buderus WK 7300-00.500 Thermostatic Head with overall dimensions
Technical drawing illustrating the overall dimensions of the thermostatic head, including height (102.5 mm) and diameter (53 mm).
Technical drawing of Buderus WK 7300-00.500 Thermostatic Head valve connection dimensions
Technical drawing detailing the dimensions of the M30x1.5 valve connection, including thread length and offset.

4. Mode d'emploi

The Buderus WK 7300-00.500 Thermostatic Head allows you to set your desired room temperature by rotating the control knob. The scale is typically marked with numbers and symbols:

  • Snowflake Symbol (): Frost protection setting. This setting prevents the room temperature from dropping below approximately 6°C (43°F), protecting pipes from freezing.
  • Chiffres (1-5) : These numbers correspond to approximate room temperatures. Each increment typically represents a change of about 4°C (7°F).
  • Réglage 1 : Environ 12°C (54°F)
  • Réglage 2 : Environ 16°C (61°F)
  • Réglage 3 : Approximately 20°C (68°F) - Recommended comfort setting
  • Réglage 4 : Environ 24°C (75°F)
  • Réglage 5 : Maximum heat, approximately 28°C (82°F)
  • Sun Symbol (): Often indicates a higher comfort setting, typically around 20-21°C (68-70°F), similar to setting 3.

To adjust the temperature, simply rotate the control knob until the desired number or symbol aligns with the indicator mark on the head.

5. Entretien

The Buderus WK 7300-00.500 Thermostatic Head requires minimal maintenance to ensure continued efficient operation.

  • Nettoyage: Essuyez l'extérieur de la tête thermostatique avec un chiffon doux et sec.amp Chiffon. N’utilisez pas de nettoyants abrasifs ni de solvants, car ils pourraient endommager la surface.
  • Vérification du fonctionnement : Periodically check that the control knob turns smoothly and that the radiator heats up and cools down as expected when adjusting the setting.
  • Évitez les obstacles : Ensure that curtains, furniture, or other objects do not obstruct the thermostatic head, as this can interfere with its ability to accurately sense room temperature.

6. Dépannage

If you experience issues with your thermostatic head, consider the following common problems and solutions:

  • Radiateur ne chauffant pas :
    • Assurez-vous que la tête thermostatique est réglée sur une température supérieure à la température ambiante actuelle.
    • Check if the valve pin is stuck. Remove the thermostatic head and gently press the pin in the valve body. It should move freely. If stuck, it may need lubrication or professional attention.
    • Verify that the central heating system is operational and that other radiators are heating.
  • Radiator Always Hot (even on low setting):
    • Ensure the thermostatic head is correctly installed and tightened.
    • The valve pin might be stuck in the open position. Try the method described above to free it.
    • The thermostatic head might be faulty and require replacement.
  • Inconsistent Room Temperature:
    • Check for drafts or obstructions around the thermostatic head that could affect its temperature sensing.
    • Ensure the heating system is balanced.

If these steps do not resolve the issue, contact a qualified heating technician.

7. Spécifications

SpécificationDétail
FabricantBudérus
Code de l'article80570357
Dimensions du colis11 x 8.8 x 7 cm
Référence constructeur80570357
Piles incluses ?Non
Des piles sont-elles nécessaires ?Non
Poids de l'article120 g
ASINB007TFIQ3M
Disponible sur Amazon.it depuis1 septembre 2012

8. Garantie et assistance

This Buderus product is covered by the manufacturer's standard warranty. For specific warranty terms and conditions, please refer to the documentation provided with your purchase or contact Buderus customer support directly. If you require technical assistance or have questions not covered in this manual, please reach out to your retailer or a certified Buderus service partner.

Documents connexes - Semaine 7300-00.500

Préview Buderus Panel Radiators Model 21 & 22: Applications Manual and Installation Guide
Comprehensive applications manual for Buderus Model 21 and Model 22 panel radiators, covering product description, specifications, installation guidelines, output ratings, selection procedures, and piping arrangements for hydronic heating systems.
Préview Guide de démarrage rapide du thermostat de radiateur Buderus THK
Guide concis d'installation, de configuration et d'utilisation du thermostat intelligent pour radiateur Buderus THK. Comprend les instructions d'installation, la connexion à l'application, les spécifications techniques et les informations relatives à la mise au rebut.
Préview Schéma de câblage et fiche technique du module fonctionnel Buderus FM441view
Schéma de câblage détaillé et informations techniques du module fonctionnel Buderus FM441, couvrant les circuits de chauffage et les systèmes de production d'eau chaude sanitaire (ECS). Comprend les connexions des composants et les états de commutation.
Préview Buderus MCM10 Installation and Technical Specifications
Comprehensive installation, technical specifications, and operating guide for the Buderus MCM10 heating control module. Includes wiring diagrams, troubleshooting, and system integration details for heating contractors.
Préview Buderus FM458 Strategy Module Service Instructions
Comprehensive service instructions for the Buderus FM458 Strategy Module, detailing installation, operation, and troubleshooting for heating contractors working with Buderus heating systems and the Logamatic 4000 control system.
Préview Buderus FM442 Function Module Wiring Diagram for Two Heating Zones
Detailed wiring diagram and technical information for the Buderus FM442 function module, designed for controlling two heating zones. Includes component connections, switching states, and installation notes.