1. Introduction
This manual provides detailed instructions for the safe and effective operation of the KAISE SK-7720 Clamp Meter. The SK-7720 is a versatile instrument designed for accurate electrical measurements in automotive and mechanical maintenance applications. It features a current and voltage double display, True RMS measurement for distorted waveforms, and functions such as Peak Hold, Max/Min recording, and deviation measurement. The main case is designed with dustproof and splash-proof characteristics for enhanced durability.
2. Consignes de sécurité
Always observe the following safety precautions to prevent electric shock or personal injury, and to avoid damage to the meter or the equipment under test.
- Read and understand all instructions in this manual before using the meter.
- N’utilisez pas l’appareil s’il semble endommagé ou si son isolation est compromise.
- Ensure the rotary switch is in the correct position for the measurement being performed.
- Ne dépassez pas les limites d'entrée maximales pour aucune fonction.
- Soyez prudent lorsque vous travaillez avec des volumestages au-dessus de 30 V CA RMS, 42 V crête ou 60 V CC. Ces voltagils présentent un risque d'électrocution.
- Remplacez immédiatement la pile dès que le voyant de pile faible s'allume afin de garantir des mesures précises.
- Ne pas utiliser l'appareil de mesure dans des environnements explosifs contenant des gaz, des vapeurs ou de la poussière.
3. Composants et caractéristiques du produit

Figure 1: KAISE SK-7720 Clamp Plus de mètreview
This image displays the KAISE SK-7720 Clamp Meter. It features a black body with a large clamp jaw at the top for non-contact current measurement. The front panel includes a rotary switch for function selection (OFF, DC Current + DC Voltage, AC Current + Frequency, AC Voltage + Frequency, Resistance, Temperature), four blue buttons (DUTY, DIFF, REC), and one yellow button (DH for Data Hold). A clear LCD screen shows measurement values, such as '1000 A' and '650 V'. Below the screen are input terminals labeled CH2 (°C Ω), COM (Common), and VΩ, with maximum voltage ratings indicated (MAX 600V, MAX 650V).
Caractéristiques principales :
- Clamp Mâchoire: For non-contact measurement of AC/DC current.
- Commutateur rotatif : Selects measurement functions (OFF, A+V, A+Hz, V+Hz, Ω, °C).
- Écran LCD : Digital readout of measurements, including dual display for current/voltage.
- Boutons de fonction :
- DEVOIR: Mesure du cycle de service.
- DIFF : Differential measurement.
- REC : Record function (Max/Min).
- DH: Maintien de données.
- Bornes d'entrée: Pour voltage, resistance, and temperature probe connections.
4. Configuration et installation de la batterie
4.1 Installation de la batterie
- Assurez-vous que le compteur est éteint.
- Repérez le couvercle du compartiment à piles à l'arrière du compteur.
- Utilisez un tournevis pour retirer la vis qui fixe le couvercle de la batterie.
- Insérez une pile 9V 6F22 en respectant la polarité (+/-).
- Replacez le couvercle de la batterie et fixez-le avec la vis.
4.2 Mise sous tension initiale
Turn the rotary switch from the "OFF" position to any measurement function. The LCD display will illuminate, indicating the meter is ready for use. If the display does not light up, check the battery installation or replace the battery.
5. Mode d'emploi
The KAISE SK-7720 offers various measurement modes. Always select the appropriate function before connecting the meter to a circuit.
5.1 Current Measurement (A)
Pour mesurer le courant alternatif ou continu :
- Tournez le commutateur rotatif vers le A+V (courant continu) ou A+Hz (Courant alternatif) position.
- Ouvrir le clamp mâchoire en appuyant sur le levier.
- Enfermez un seul conducteur du circuit à l'intérieur de la clôture.amp jaw. Ensure the jaw is fully closed. The maximum measurement conductor diameter is 36 mm (1.4 inches).
- Lire la valeur actuelle sur l'écran LCD.
Vol 5.2tage Mesure (V)
Pour mesurer le vol AC ou DCtage:
- Connectez le cordon de test noir au COM borne et le fil de test rouge à la VΩ Terminal.
- Tournez le commutateur rotatif vers le A+V (DC Vol.tage) ou V+Hz (AC Voltage) poste.
- Connectez les cordons de test en parallèle au circuit ou au composant que vous souhaitez mesurer.
- Lire le voltage valeur sur l'écran LCD.
5.3 Mesure de résistance (Ω)
Pour mesurer la résistance :
- Connectez le cordon de test noir au COM borne et le fil de test rouge à la CH2 (°C Ω) Terminal.
- Tournez le commutateur rotatif vers le Ω position.
- Ensure the circuit or component under test is de-energized before connecting the test leads.
- Connectez les cordons de test aux bornes du composant.
- Lisez la valeur de résistance sur l'écran LCD.
5.4 Mesure de fréquence (Hz)
Frequency can be measured in conjunction with AC Current or AC Voltage:
- For AC Current frequency, select A+Hz.
- Pour AC Voltage frequency, select V+Hz.
- The frequency value will be displayed on the secondary display or indicated by a specific symbol.
5.5 Mesure de la température (°C)
Pour mesurer la température :
- Connect a compatible temperature probe (not included) to the CH2 (°C Ω) et COM terminaux.
- Tournez le commutateur rotatif vers le °C position.
- Place the temperature probe at the desired measurement point.
- Lisez la valeur de la température sur l'écran LCD.
5.6 boutons de fonction
- DEVOIR: Press to measure the duty cycle of a signal.
- DIFF : Activates differential measurement mode. Refer to the full manual for detailed usage.
- REC : Press to activate the recording function, allowing the meter to capture maximum and minimum readings. Press again to cycle through MAX, MIN, and current readings.
- DH (Data Hold): Appuyez pour figer la lecture actuelle sur l'écran. Appuyez de nouveau pour relâcher.
6. Entretien
6.1 Nettoyage
Essuyez le boîtier avec la publicitéamp Chiffon et détergent doux. Ne pas utiliser de produits abrasifs ni de solvants. S'assurer que l'appareil est parfaitement sec avant utilisation.
6.2 Remplacement de la batterie
Remplacez la pile 9 V lorsque le témoin de pile faible s'affiche. Consultez la section 4.1 pour les instructions d'installation de la pile.
6.3 Stockage
Si l'appareil n'est pas utilisé pendant une période prolongée, retirez la pile pour éviter les fuites et les dommages. Rangez-le dans un endroit frais et sec, à l'abri de la lumière directe du soleil.
7. Dépannage
| Problème | Cause possible | Solution |
|---|---|---|
| Le compteur ne s'allume pas. | Batterie déchargée ou mal installée. | Vérifiez la polarité de la pile ou remplacez la pile 9V. |
| Lectures inexactes. | Low battery, incorrect function selected, or external interference. | Replace battery, verify function setting, move away from strong electromagnetic fields. |
| Affichage de « OL » ou « OVER ». | La mesure dépasse la plage de mesure de l'appareil. | Select a higher range if available, or ensure the input is within specifications. |
8. Spécifications techniques
- Modèle: SK-7720
- Type de mesure: Clamp Meter (Ammeter, Voltmeter, Ohmmeter, Frequency, Temperature)
- Current Frequency Response (ACA): 40Hz - 400Hz
- Voltage Frequency Response (ACV): 40Hz - 400Hz
- Batterie: 1 x 9V 6F22 (included)
- Dimensions: 200 x 64 x 33 mm (7.9 x 2.5 inches)
- Poids: 310 gramme
- Measurement Conductor Diameter: 36 mm (1.4 pouces)
- Caractéristiques: True RMS, Peak Hold, Max/Min, Deviation Measurement, Dustproof and Splash-proof (main case).
9. Informations sur la garantie
This KAISE SK-7720 Clamp Meter is covered by a standard manufacturer's warranty against defects in materials and workmanship. The warranty period typically begins from the date of purchase. Please retain your proof of purchase for warranty claims. This warranty does not cover damage caused by misuse, accident, unauthorized repair, or normal wear and tear. For specific warranty terms and conditions, please refer to the documentation provided with your purchase or contact Kaise customer support.
10. Assistance clientèle
For technical assistance, troubleshooting, or service inquiries regarding your KAISE SK-7720 Clamp Meter, please contact your local distributor or the manufacturer's customer support. You may find contact information on the product packaging or the official Kaise website.
Fabricant: Kaise