ASHCROFT 251009SW02BXLLVAC

Manuel d'utilisation du manomètre à vide ASHCROFT

Model: 251009SW02BXLLVAC

1. Introduction

This manual provides essential information for the proper installation, operation, and maintenance of your ASHCROFT Vacuum Gauge. This test gauge is designed for precise vacuum measurement, featuring a durable construction suitable for industrial applications.

The gauge has a 2-1/2 inch dial, measures vacuum from 30 inches of Mercury (Hg) to 0, and features a 1/4 inch NPT connection located at the lower back. It is constructed with a 304 stainless steel case, 316 stainless steel socket and tube, and a polycarbonate lens. The gauge is filled with glycerin for dampening and enhanced performance.

ASHCROFT Vacuum Gauge

Figure 1 : ASHCROFT Vacuum Gauge. This image displays the front view of the vacuum gauge, highlighting its stainless steel casing, white dial with black markings, and the ASHCROFT DURALIFE branding. The gauge face indicates measurements in psi and notes "Welded AISI 316 tube & socket U.S.A."

2. Consignes de sécurité

Always observe standard safety precautions when handling and installing pressure and vacuum gauges. Failure to do so may result in injury or damage to equipment.

  • Ensure the system is depressurized before installing or removing the gauge.
  • Do not exceed the specified operating range of 30" Hg Vac to 0.
  • Verify compatibility of the gauge's wetted parts (316 Stainless Steel) with the process media.
  • Protect the gauge from extreme temperatures outside the -40°F to 150°F operating range.
  • Handle with care to avoid dropping or impacting the gauge, which can affect accuracy.

3. Configuration et installation

Proper installation is crucial for accurate readings and long service life.

  1. Préparation: Ensure the connection port on your system is clean and free of debris.
  2. Connexion: The gauge features a 1/4 inch NPT (National Pipe Taper) connection. Apply appropriate thread sealant (e.g., PTFE tape) to the male threads of the gauge connection.
  3. Montage: Carefully thread the gauge into the system's female NPT port. Tighten using a wrench on the wrench flats of the gauge connection. Do not overtighten or apply torque to the gauge case.
  4. Orientation: The connection location is lower back, allowing for direct mounting or panel mounting with appropriate accessories (not included). Ensure the dial is easily visible for reading.

4. Mode d'emploi

The ASHCROFT Vacuum Gauge provides accurate vacuum measurements within its specified range.

  • Lecture de la jauge : The dial is marked from 30" Hg Vac (full vacuum) to 0 (atmospheric pressure). The smallest graduation is 0.5" Hg, allowing for precise readings.
  • Précision: This gauge has an accuracy of +/-1.0% of span, ensuring reliable measurements for test applications.
  • Considérations relatives à la température : The gauge is designed to operate effectively within a temperature range of -40°F to 150°F. Operating outside this range may affect accuracy and longevity.
  • Glycerin Fill: The glycerin fill dampens pointer pulsation caused by vibration and pressure surges, improving readability and extending the life of the gauge movement.

5. Entretien

Regular maintenance ensures the longevity and accuracy of your vacuum gauge.

  • Nettoyage: Clean the exterior of the gauge, especially the polycarbonate lens, with a soft, damp cloth. Avoid abrasive cleaners or solvents that could damage the lens or case.
  • Inspection: Periodically inspect the gauge for any signs of damage, such as cracks in the lens, dents in the case, or bent pointer. Check the connection for leaks.
  • Recalibrage : While designed for long-term accuracy, professional recalibration may be necessary if the gauge is subjected to severe conditions or if accuracy is critical for your application.
  • Stockage: When not in use, store the gauge in a clean, dry environment within its operating temperature range.

6. Dépannage

Veuillez vous référer aux problèmes courants suivants et à leurs solutions potentielles :

ProblèmeCause possibleSolution
Lecture inexacteGauge exposed to over-vacuum; physical damage; extreme temperature.Verify operating conditions; inspect for damage; allow gauge to normalize temperature. Consider professional recalibration or replacement.
Pointer FluctuationSystem vibration; rapid pressure changes.The glycerin fill helps dampen this; ensure gauge is securely mounted. If severe, consider a snubber or remote mounting.
Leak at ConnectionImproperly applied thread sealant; insufficient tightening.Depressurize system, remove gauge, reapply thread sealant, and re-install, ensuring proper tightening.

7. Spécifications

Detailed technical specifications for the ASHCROFT Vacuum Gauge (Model: 251009SW02BXLLVAC).

  • Type de jauge : Test
  • Taille du cadran : 2-1/2 pouces
  • Gamme: 30" Hg Vac to 0
  • Taille de connexion: 1/4" NPT
  • Emplacement de connexion: Lombes
  • Smallest Graduation: 0.5" Hg
  • Précision: +/-1.0%
  • Matériau du boîtier : Acier inoxydable 304
  • Couleur du boîtier : Argent
  • Matériau de la douille : Acier inoxydable 316
  • Matériau du tube : Acier inoxydable 316
  • Remplir: Glycérine
  • Matériau de la lentille : Polycarbonate
  • Ring Material: Acier inoxydable
  • Plage de température de fonctionnement : -40°F à 150°F
  • Série: 1009
  • Dimensions du produit : 3 x 3 x 3 pouces
  • Poids de l'article : 1 livre
  • Pays d'origine : USA
  • Code à barres : 094706106517

8. Garantie et assistance

This ASHCROFT Vacuum Gauge comes with a Garantie constructeur d'un an. For warranty claims or technical support, please contact ASHCROFT customer service. Retain your proof of purchase for warranty validation.

For further assistance or detailed technical inquiries, please refer to the official ASHCROFT webconsultez leur site web ou contactez leurs distributeurs agréés.

Documents connexes - 251009SW02BXLLVAC

Préview Ashcroft Model 1490 Low Pressure Diaphragm Gauge Installation Instructions
Comprehensive installation guide for the Ashcroft Model 1490 Low Pressure Diaphragm Gauge, detailing safety warnings, product specifications, installation procedures, and accuracy information for industrial pressure measurement applications.
Préview Guide d'installation et de maintenance des thermocouples et RTD Ashcroft S10 et S50
Fournit des instructions détaillées d'installation et de maintenance pour les capteurs de température RTD et thermocouples Ashcroft S10 et S50. Ce document couvre les précautions générales, le stockage, les procédures d'installation spécifiques aux RTD et thermocouples, ainsi que les consignes de maintenance pour garantir des mesures précises et une longue durée de vie.
Préview Instructions d'installation du manomètre/commutateur de pression différentielle Ashcroft modèles 1130 et 1140
Instructions d'installation et caractéristiques techniques des manomètres différentiels Ashcroft modèles 1130 et 1140 avec interrupteurs en option. Ce document décrit le principe de fonctionnement, l'installation, les précautions à prendre et le câblage des interrupteurs.
Préview Guide d'installation et d'entretien des pressostats à action brusque Ashcroft B400 et B700
Ce guide fournit les informations essentielles pour l'installation et la maintenance des pressostats à action brusque Ashcroft des séries B400 et B700. Il couvre le produit et ses caractéristiques.view, dimensions, montage, connexions électriques et de conduits, procédures de réglage du point de consigne et pratiques recommandées pour un fonctionnement sûr et fiable.
Préview Manomètres Ashcroft pour la construction de skids et l'ingénierie des installations industrielles | Mesure de pression
Découvrez la gamme de manomètres pour châssis d'Ashcroft, conçus pour les applications industrielles exigeantes. Fabriqués en acier inoxydable, Hastelloy, Monel et Inconel, ils sont accompagnés de spécifications techniques détaillées.
Préview Ashcroft S1 Pressure Transducer: Features, Specifications, and Ordering Guide
Comprehensive data sheet for the Ashcroft S1 Pressure Transducer, detailing its features, typical uses, technical specifications, environmental and electrical ratings, output signals, ordering codes, and dimensional information.