This document provides instructions for the Broan-NuTone 8663RP Motor Assembly, part number 97017705. This motor is designed as a replacement component for various NuTone and Broan ventilation fan models. It operates at 1550 RPM, 1.2 amps, and 115 volts, ensuring efficient air circulation.
Caractéristiques principales :
- Shaft: 1/4" x 1"
- Rotation: Counter-Clockwise (CCW)
- Motor Diameter: 3.3"
- Sheet Metal Dimensions: 8 15/16" x 8 15/16"
- Wheel Dimensions: 5.75" x 2"
- Mounting: 2 Studs Opposite Shaft End
- Motor Case Length: 1 15/16"
- Electrical Connection: 2-Prong 115 Volt plug
Compatibilité
The Broan-NuTone 8663RP Motor Assembly is compatible with the following ventilation fan models:
- Broan: 750, 751, 752, N750
- NuTone: 8663RF, 8663RFT, 8663RLG, 8663RMAB, 8663RMBR, 8663RMS, 8673RP, 8663RMSA, 8663RP, 8664RP, 671R, 672R, VL3668RLG, VL3668RMAB, VL3668RMBR, VL3668RMSA, VL3668RP
Caractéristiques
| Attribut | Valeur |
|---|---|
| Marque | Broan-NuTone |
| Vitesse | 1550 tr/min |
| Voltage | 115 volts |
| Puissance | 115 watts |
| Dimensions du produit | 8.94 po L x 8.94 po H |
| Matériel | Métal |
| Poids de l'article | 3.74 livres |
| Fabricant | EAGLEGGO |
| Code UPC | 663001340782 |
| ASIN | B006IO918O |
| Numéro de modèle de l'article | CÉCOMINOD088831 |
| Date de première disponibilité | 21 septembre 2012 |
Installation
La sécurité avant tout : Before beginning any installation, ensure the power supply to the ventilation fan unit is completely disconnected at the circuit breaker. Failure to do so may result in electrical shock or injury.
- Access the Fan Housing: Remove the fan grille and any light covers to expose the existing motor assembly within the fan housing.
- Débranchez l'ancien moteur : Carefully unplug the old motor assembly from its electrical connection. Note the orientation and connection points.
- Retirer l'ancien moteur : Unfasten any screws or clips securing the old motor assembly to the fan housing. Gently remove the old unit.
- Installer le nouveau moteur : Position the new Broan-NuTone 8663RP motor assembly into the fan housing. Ensure the mounting studs align with the existing holes. Secure the new motor with the appropriate fasteners.
- Raccordement électrique : Plug the 2-prong 115 Volt plug of the new motor into the fan's electrical receptacle. Ensure a secure connection.
- Opération de test : Temporarily restore power to the fan and test its operation. Verify that the motor runs smoothly and the fan blade rotates correctly.
- Remonter: Once confirmed operational, disconnect power again. Reattach any light covers and the fan grille. Restore power to the unit.
Note: For detailed, model-specific installation instructions, always refer to the original instruction manual for your specific Broan or NuTone ventilation fan model.
Opération
The Broan-NuTone 8663RP Motor Assembly is designed for continuous and reliable operation within compatible ventilation fan units. Once installed, the fan will operate according to the controls of your specific ventilation system (e.g., wall switch, timer).
- Activation : Turn on the fan using its designated wall switch or control.
- Débit d'air : The motor will drive the fan blade to exhaust air from the room.
- Désactivation: Turn off the fan using its designated wall switch or control.
Ensure proper ventilation by operating the fan during and after activities that generate moisture or odors.
Entretien
Regular maintenance helps ensure the longevity and optimal performance of your ventilation fan motor assembly.
- Coupure de courant : Coupez toujours l'alimentation au niveau du disjoncteur avant d'effectuer toute opération de maintenance.
- Nettoyer la grille du ventilateur : Periodically remove and clean the fan grille with mild soap and water. Allow it to dry completely before reattaching.
- Clean Fan Blade: If accessible, gently wipe dust and debris from the fan blade using a soft cloth. Avoid bending the blades.
- Inspecter le moteur : Visually inspect the motor for any signs of wear, loose connections, or unusual buildup.
- Lubrification: This motor assembly is typically designed for maintenance-free operation and does not require lubrication. Refer to your specific fan model's manual for any lubrication recommendations.
Do not use abrasive cleaners or solvents on any part of the fan or motor.
Dépannage
If your ventilation fan is not operating as expected after installing the new motor assembly, consider the following common issues:
- Le ventilateur ne s'allume pas :
- Vérifiez si le disjoncteur est déclenché.
- Ensure the motor's electrical plug is securely connected.
- Verify the wall switch is functioning correctly.
- Fan Running Loudly or Vibrating:
- Ensure the motor assembly is securely mounted and all fasteners are tightened.
- Check for any obstructions around the fan blade.
- Inspect the fan blade for damage or imbalance.
- Mauvaise circulation d'air :
- Clean the fan grille and fan blade to remove dust and debris.
- Check for blockages in the exhaust ductwork.
If issues persist after basic troubleshooting, consult a qualified electrician or HVAC technician.
Visuels du produit



Aucune vidéo officielle du vendeur n'était disponible pour être intégrée à ce manuel.
Consignes de sécurité
- Toujours couper l'alimentation électrique avant d'installer, d'entretenir ou de nettoyer l'appareil.
- Portez un équipement de protection individuelle (EPI) approprié, tel que des gants et une protection oculaire, pendant l'installation.
- Assurez-vous que tous les branchements électriques sont sécurisés et conformes aux normes électriques locales.
- Do not operate the fan if it is damaged or if any parts are missing.
- Tenez les enfants et les animaux domestiques éloignés de la zone de travail pendant l'installation et la maintenance.