1. Introduction
This manual provides essential information for the safe and effective installation, operation, and maintenance of the Eaton Cutler-Hammer BRH2125 Circuit Breaker. The BRH2125 is a 2-pole, 125 Amp circuit breaker designed for 120/240V AC/CA systems, featuring a common trip mechanism and HACR type rating. Please read this manual thoroughly before proceeding with any installation or operation.
2. Informations importantes sur la sécurité
WARNING: Risk of electric shock or electrocution. Installation and servicing of this circuit breaker must be performed by qualified electrical personnel only. Always disconnect power at the main service panel before working on electrical circuits.
- Ensure all power is OFF before installation or maintenance.
- Utilisez un équipement de protection individuelle (EPI) approprié.
- Vérifier le voltage and current ratings match your electrical system requirements.
- N'utilisez pas cet appareil s'il semble endommagé.
- Respectez tous les codes électriques locaux et nationaux.
3. Instructions d'installation
The BRH2125 is a plug-in mount circuit breaker. Ensure the load center or panelboard is compatible with BR type breakers.

This image shows the Eaton Cutler-Hammer BRH2125 circuit breaker from an angled top-down view, highlighting the 'On/I' and 'Off/O' indicators, the 125 Amp rating, and the product labeling including 'Cutler-Hammer Type BRH2125', '120/240 V AC/CA', and '2 Pole'.
Étapes d'installation :
- Débrancher l'alimentation : Coupez l'alimentation principale du tableau électrique au niveau du compteur ou du disjoncteur principal. Vérifiez que le courant est bien coupé à l'aide d'un testeur de tension.tage testeur.
- Retirer le cache du panneau : Retirez délicatement le couvercle du panneau électrique.
- Identifier l'emplacement : Locate an available slot in the panelboard that is compatible with a 2-pole BR type circuit breaker.
- Installer le disjoncteur : Position the BRH2125 circuit breaker so its clips align with the bus bar stabs in the panel. Firmly press the breaker onto the bus bar until it is securely seated.
- Connecter le câblage : Connect the load wires (typically two hot wires for a 2-pole breaker) to the appropriate terminals on the circuit breaker. The BRH2125 is compatible with both copper (Cu) and aluminum (Al) wiring. Ensure connections are tight according to torque specifications (refer to panel label or breaker markings).
- Remplacer le couvercle du panneau : Once wiring is complete and secure, replace the electrical panel cover.
- Restaurer l'alimentation : Remettez l'alimentation principale en marche.
4. Operating the Circuit Breaker
The BRH2125 circuit breaker features a toggle switch for manual operation and a common trip mechanism for safety.

This close-up image displays the operating labels on the circuit breaker, clearly showing the 'On/I' and 'Off/O' positions for each pole, along with the '125' amp rating. The 'Common Trip' label is also visible, indicating that both poles trip simultaneously.
Postes opérationnels :
- SUR (I) : Pushing the toggle switch to the 'On/I' position connects power to the circuit.
- OFF (O) : Pushing the toggle switch to the 'Off/O' position disconnects power from the circuit.
- DÉBORDÉ : If an overload or short circuit occurs, the breaker will automatically move to a central, tripped position (often indicated by the toggle being between ON and OFF, or fully OFF with a red indicator). This is the 'Common Trip' feature, meaning both poles disconnect simultaneously.
Réarmement d'un disjoncteur déclenché :
- Identifier la cause : Before resetting, identify and correct the cause of the trip (e.g., unplug overloaded appliances).
- Totalement éteint : Push the breaker handle firmly to the full 'Off/O' position. You may hear a click.
- Reset to ON: Then, push the handle firmly to the 'On/I' position.
5. Entretien
The Eaton Cutler-Hammer BRH2125 circuit breaker requires minimal maintenance. Regular inspection is recommended to ensure proper function and safety.
- Inspection annuelle: Inspectez périodiquement le disjoncteur afin de déceler tout signe de dommage physique, de décoloration ou de connexions desserrées.
- Nettoyage: Keep the area around the circuit breaker clean and free of dust and debris. Use a dry, non-abrasive cloth for cleaning. Do not use liquids or sprays.
- Essai: While not typically required for residential breakers, some applications may necessitate periodic testing by a qualified electrician.
6. Dépannage
If your circuit breaker trips frequently or fails to operate correctly, consider the following:
- Déclenchements fréquents : This often indicates an overloaded circuit or a short circuit. Disconnect some appliances from the circuit or investigate for faulty wiring/appliances.
- Le disjoncteur ne se réinitialise pas : If the breaker immediately trips again after being reset, there is likely a persistent overload or short circuit. Do not force the breaker. Consult a qualified electrician.
- No Power, Breaker Not Tripped: Check the main service panel for a tripped main breaker. If other circuits are working, the issue might be with the wiring to the specific circuit or a faulty appliance.
- Dégâts physiques : If the breaker shows signs of burning, melting, or other damage, it must be replaced immediately by a qualified electrician.
For persistent issues, always consult a qualified electrician.
7. Spécifications techniques
| Spécification | Valeur |
|---|---|
| Marque | Eaton / Cutler-Hammer |
| Numéro de modèle | BRH2125 |
| Évaluation actuelle | 125 Amps |
| Voltage Note | 120/240 Volts AC/CA |
| Nombre de pôles | 2 |
| Type de disjoncteur | Standard, HACR Type |
| Type de montage | Montage enfichable |
| Compatibilité des fils | Cu/Al |
| Matériel | Cuivre (composants internes) |
| Poids de l'article | 13.1 onces |
| Dimensions | 3.7 x 3.35 x 2.24 pouces |
| Fabricant | CUTLER HAMMER |
| Code UPC | 696505474691 |
8. Garantie et assistance
This Eaton Cutler-Hammer BRH2125 Circuit Breaker is covered by the manufacturer's standard warranty. For specific warranty details, claims, or technical support, please refer to the official Eaton webConsultez le site ou contactez directement leur service client. Conservez votre reçu d'achat comme preuve d'achat.
Eaton Customer Support: www.eaton.com/us/en/support.html