Eaton BRH2125

Eaton Cutler-Hammer BRH2125 Circuit Breaker Instruction Manual

Modèle : BRH2125

1. Introduction

This manual provides essential information for the safe and effective installation, operation, and maintenance of the Eaton Cutler-Hammer BRH2125 Circuit Breaker. The BRH2125 is a 2-pole, 125 Amp circuit breaker designed for 120/240V AC/CA systems, featuring a common trip mechanism and HACR type rating. Please read this manual thoroughly before proceeding with any installation or operation.

2. Informations importantes sur la sécurité

WARNING: Risk of electric shock or electrocution. Installation and servicing of this circuit breaker must be performed by qualified electrical personnel only. Always disconnect power at the main service panel before working on electrical circuits.

  • Ensure all power is OFF before installation or maintenance.
  • Utilisez un équipement de protection individuelle (EPI) approprié.
  • Vérifier le voltage and current ratings match your electrical system requirements.
  • N'utilisez pas cet appareil s'il semble endommagé.
  • Respectez tous les codes électriques locaux et nationaux.

3. Instructions d'installation

The BRH2125 is a plug-in mount circuit breaker. Ensure the load center or panelboard is compatible with BR type breakers.

Eaton Cutler-Hammer BRH2125 2-Pole 125A Circuit Breaker

This image shows the Eaton Cutler-Hammer BRH2125 circuit breaker from an angled top-down view, highlighting the 'On/I' and 'Off/O' indicators, the 125 Amp rating, and the product labeling including 'Cutler-Hammer Type BRH2125', '120/240 V AC/CA', and '2 Pole'.

Étapes d'installation :

  1. Débrancher l'alimentation : Coupez l'alimentation principale du tableau électrique au niveau du compteur ou du disjoncteur principal. Vérifiez que le courant est bien coupé à l'aide d'un testeur de tension.tage testeur.
  2. Retirer le cache du panneau : Retirez délicatement le couvercle du panneau électrique.
  3. Identifier l'emplacement : Locate an available slot in the panelboard that is compatible with a 2-pole BR type circuit breaker.
  4. Installer le disjoncteur : Position the BRH2125 circuit breaker so its clips align with the bus bar stabs in the panel. Firmly press the breaker onto the bus bar until it is securely seated.
  5. Connecter le câblage : Connect the load wires (typically two hot wires for a 2-pole breaker) to the appropriate terminals on the circuit breaker. The BRH2125 is compatible with both copper (Cu) and aluminum (Al) wiring. Ensure connections are tight according to torque specifications (refer to panel label or breaker markings).
  6. Remplacer le couvercle du panneau : Once wiring is complete and secure, replace the electrical panel cover.
  7. Restaurer l'alimentation : Remettez l'alimentation principale en marche.

4. Operating the Circuit Breaker

The BRH2125 circuit breaker features a toggle switch for manual operation and a common trip mechanism for safety.

Close-up of Eaton BRH2125 circuit breaker labels showing 'On/I', 'Off/O', and '125' amp notation.

This close-up image displays the operating labels on the circuit breaker, clearly showing the 'On/I' and 'Off/O' positions for each pole, along with the '125' amp rating. The 'Common Trip' label is also visible, indicating that both poles trip simultaneously.

Postes opérationnels :

  • SUR (I) : Pushing the toggle switch to the 'On/I' position connects power to the circuit.
  • OFF (O) : Pushing the toggle switch to the 'Off/O' position disconnects power from the circuit.
  • DÉBORDÉ : If an overload or short circuit occurs, the breaker will automatically move to a central, tripped position (often indicated by the toggle being between ON and OFF, or fully OFF with a red indicator). This is the 'Common Trip' feature, meaning both poles disconnect simultaneously.

Réarmement d'un disjoncteur déclenché :

  1. Identifier la cause : Before resetting, identify and correct the cause of the trip (e.g., unplug overloaded appliances).
  2. Totalement éteint : Push the breaker handle firmly to the full 'Off/O' position. You may hear a click.
  3. Reset to ON: Then, push the handle firmly to the 'On/I' position.

5. Entretien

The Eaton Cutler-Hammer BRH2125 circuit breaker requires minimal maintenance. Regular inspection is recommended to ensure proper function and safety.

  • Inspection annuelle: Inspectez périodiquement le disjoncteur afin de déceler tout signe de dommage physique, de décoloration ou de connexions desserrées.
  • Nettoyage: Keep the area around the circuit breaker clean and free of dust and debris. Use a dry, non-abrasive cloth for cleaning. Do not use liquids or sprays.
  • Essai: While not typically required for residential breakers, some applications may necessitate periodic testing by a qualified electrician.

6. Dépannage

If your circuit breaker trips frequently or fails to operate correctly, consider the following:

  • Déclenchements fréquents : This often indicates an overloaded circuit or a short circuit. Disconnect some appliances from the circuit or investigate for faulty wiring/appliances.
  • Le disjoncteur ne se réinitialise pas : If the breaker immediately trips again after being reset, there is likely a persistent overload or short circuit. Do not force the breaker. Consult a qualified electrician.
  • No Power, Breaker Not Tripped: Check the main service panel for a tripped main breaker. If other circuits are working, the issue might be with the wiring to the specific circuit or a faulty appliance.
  • Dégâts physiques : If the breaker shows signs of burning, melting, or other damage, it must be replaced immediately by a qualified electrician.

For persistent issues, always consult a qualified electrician.

7. Spécifications techniques

SpécificationValeur
MarqueEaton / Cutler-Hammer
Numéro de modèleBRH2125
Évaluation actuelle125 Amps
Voltage Note120/240 Volts AC/CA
Nombre de pôles2
Type de disjoncteurStandard, HACR Type
Type de montageMontage enfichable
Compatibilité des filsCu/Al
MatérielCuivre (composants internes)
Poids de l'article13.1 onces
Dimensions3.7 x 3.35 x 2.24 pouces
FabricantCUTLER HAMMER
Code UPC696505474691

8. Garantie et assistance

This Eaton Cutler-Hammer BRH2125 Circuit Breaker is covered by the manufacturer's standard warranty. For specific warranty details, claims, or technical support, please refer to the official Eaton webConsultez le site ou contactez directement leur service client. Conservez votre reçu d'achat comme preuve d'achat.

Eaton Customer Support: www.eaton.com/us/en/support.html

Documents connexes - BRH2125

Préview 伊顿新一代空气断路器 IZM9 系列:卓越的解决方案
了解伊顿新一代 IZM9 系列空气断路器,为全球电力系统提供创新、可靠且高效的动力管理解决方案。该系列产品凭借先进的 PXR 电子脱扣平台、增强的安全特性(如 ARMS 闪弧减少维护系统)以及强大的通讯能力,广泛应用于建筑、信息技术、工业机械和能源公用事业等多个领域,满足客户日益增长和多样化的需求。
Préview Instructions d'installation et d'utilisation du disjoncteur à vide Eaton E-VAC HV
Ce guide fournit des informations essentielles sur l'installation, le fonctionnement, la maintenance et les détails techniques du climatiseur haute tension intérieur fermé Eaton E-VAC.tagDisjoncteur à vide (modèle IL550-0501001E), garantissant une utilisation sûre et efficace dans les applications industrielles et de réseau électrique.
Préview Manuel d'utilisation du disjoncteur Eaton Magnum BT-Air (1812.900A)
Manuel d'utilisation complet du disjoncteur Eaton Magnum BT-Air (modèle 1812.900A), détaillant l'installation, le fonctionnement, la maintenance, le dépannage et le remplacement des pièces. Il couvre les configurations fixes et débrochables avec systèmes de déclenchement électronique.
Préview Disjoncteurs boîtier moulé Eaton séries G et C : 15-2500 A, homologués UL, CSA et IEC
Catalogue complet détaillant les disjoncteurs boîtier moulé (MCCB) des séries G et C de Cutler-Hammer d'Eaton. Il couvre les spécifications du produit, les caractéristiques électriques, les applications et les guides de sélection pour les disjoncteurs de 15 à 2500 A. ampères, conformes aux normes UL, CSA et IEC.
Préview Notice d'installation EATON 11/25 IL019140ZU : Guide d'installation des disjoncteurs différentiels (RCCB et RCBO)
Instructions d'installation détaillées et spécifications techniques pour les disjoncteurs différentiels (DDR) et les disjoncteurs différentiels avec protection contre les surintensités (DDR) des séries EATON PL6, PL7, HN, PF6, PF7 et HNC, y compris les schémas de câblage et les données électriques.
Préview Instructions d'installation du dispositif de verrouillage à faisceau mobile pour disjoncteur LG et PD3
Notice d'installation, de montage et de réglage du dispositif de verrouillage à faisceau mobile du disjoncteur Eaton LG et PD3. Contient la liste des pièces, des schémas et les consignes de sécurité.