1. Introduction
The Atrix Omega Green Supreme IPM H13 HEPA vacuum (Model: VACOMEGASIPM) is a specialized, portable vacuum designed for pest management professionals. It offers superior filtration and convenient features for efficient operation in various environments.
Les principales caractéristiques comprennent :
- Three levels of filtration, including an H13 HEPA filter.
- Self-storage compartment for accessories.
- Powerful 1,000-hour rated Ametek® Advantek II motor.
- 25-foot detachable power cord.
- Quiet operation at less than 70dB.

This manual provides detailed instructions for the safe and effective use, maintenance, and troubleshooting of your Atrix Omega Green Supreme vacuum.
2. Consignes de sécurité
AVERTISSEMENT : ce produit peut vous exposer à des produits chimiques, dont le plomb, reconnu par l'État de Californie comme provoquant le cancer et des malformations congénitales ou d'autres problèmes de reproduction. Pour plus d'informations, rendez-vous sur www.P65Warnings.ca.gov.
Précautions générales de sécurité :
- Always unplug the vacuum from the power outlet before performing any maintenance, cleaning, or when not in use.
- Do not use the vacuum on wet surfaces or to pick up liquids. This vacuum is designed for dry pick-up only.
- Ne ramassez pas de matériaux inflammables ou combustibles, de cendres chaudes ou d'objets tranchants.
- Gardez les cheveux, les vêtements amples, les doigts et toutes les parties du corps éloignés des ouvertures et des pièces mobiles.
- Utiliser uniquement comme décrit dans ce manuel. Utiliser uniquement les accessoires recommandés par le fabricant.
- Do not operate the vacuum with a damaged cord or plug. If the vacuum is not working as it should, has been dropped, damaged, left outdoors, or dropped into water, return it to a service center.
- Ne tirez pas ou ne transportez pas avec le cordon, n'utilisez pas le cordon comme poignée, ne fermez pas une porte sur le cordon ou ne tirez pas le cordon autour des bords ou des coins tranchants. Garder le cordon éloigné des surfaces chauffées.
- Ne débranchez pas l'appareil en tirant sur le cordon. Pour débrancher, saisissez la fiche et non le cordon.
- Ne manipulez pas la prise ou l’aspirateur avec les mains mouillées.
- Cet appareil n'est pas destiné à être utilisé par des personnes (y compris les enfants) ayant des capacités physiques, sensorielles ou mentales réduites, ou manquant d'expérience et de connaissances, à moins qu'elles ne bénéficient d'une surveillance ou d'instructions concernant l'utilisation de l'appareil par une personne responsable de leur sécurité.
3. Contenu du colis
Vérifiez que tous les composants sont présents dans le package :
- Atrix Omega Green Supreme Vacuum Unit
- Guide d'utilisation (ce manuel)
- 5.6" Clear Hose
- Ground Brush
- 3 Wands with Caps
- Bandoulière
- Filtre HEPA (préinstallé ou séparé)
4. Configuration et assemblage
4.1 Attaching the Hose
- Locate the hose connection port on the side of the vacuum unit.
- Insert the larger end of the 5.6" clear hose firmly into the connection port until it clicks into place.

4.2 Assembling Wands and Attachments
- Connect the desired wand sections together by twisting them firmly.
- Attach the ground brush or other desired accessory (e.g., crevice tool) to the end of the assembled wand.
- Insert the smaller end of the hose into the open end of the wand assembly.
4.3 Connexion d'alimentation
- Assurez-vous que l'interrupteur de l'aspirateur est en position « ARRÊT ».
- Connect the detachable 25-foot power cord to the power inlet on the vacuum unit.
- Branchez le cordon d'alimentation dans une prise électrique standard de 120 V CA.

5. Mode d'emploi
5.1 Mise sous/hors tension
To turn the vacuum on, locate the power switch on the unit and flip it to the "ON" position. To turn it off, flip the switch back to the "OFF" position.
5.2 Utilisation de l'aspirateur
- Once powered on, guide the attached wand and accessory over the area to be cleaned.
- The vacuum's powerful suction will collect dust, debris, and pests into the HEPA filter system.
- For hands-free operation, attach the included shoulder strap to the designated loops on the vacuum unit.

The HEPA filter is 99.97% efficient at 0.3 microns, effectively capturing a wide range of particles including bed bugs, cockroaches, rodent droppings, dry chemicals, and hazardous materials.
6. Entretien
6.1 Remplacement du filtre HEPA
The 1-gallon HEPA filter is designed for immediate containment and should be replaced when suction power decreases significantly or when the filter appears full. The filter includes three layers of 56 pleat media (one cellulose, two glass layers).
- Assurez-vous que l’aspirateur est débranché de la prise de courant.
- Open the vacuum unit to access the filter compartment (refer to Figure 3).
- Carefully remove the old HEPA filter, ensuring not to dislodge any captured debris.
- Dispose of the old filter according to local regulations for hazardous waste, if applicable.
- Insert a new Atrix replacement HEPA filter, ensuring it is seated correctly.
- Close the vacuum unit securely.
6.2 Cleaning the Unit and Accessories
- Wipe down the exterior of the vacuum unit with a damp tissu. N'utilisez pas de produits chimiques agressifs ou de nettoyants abrasifs.
- Clean the hose and accessories as needed. Ensure they are dry before reattaching.
- Before transport or storage, utilize the hose and filter plugs to prevent any pests or debris from escaping or spilling out.
7. Dépannage
| Problème | Cause possible | Solution |
|---|---|---|
| L'aspirateur ne s'allume pas. | No power to the unit; power cord not fully plugged in; power switch off. | Check power outlet; ensure power cord is securely plugged into both the unit and the wall; confirm power switch is in "ON" position. |
| Aspiration réduite. | Full or clogged HEPA filter; clogged hose or attachment; hose not securely attached. | Replace HEPA filter; check hose and attachments for blockages and clear them; ensure hose is firmly connected to the unit and wand. |
| Bruit inhabituel pendant le fonctionnement. | Foreign object in hose or attachment; motor issue. | Turn off and unplug the vacuum. Inspect hose and attachments for obstructions and remove them. If noise persists, contact customer support. |
8. Spécifications
| Fonctionnalité | Détail |
|---|---|
| Marque | Atrix |
| Nom du modèle | VACOMEGASIPM |
| Couleur | Vert |
| Dimensions du produit | 20.25"L x 7.75"l x 10.75"H |
| Poids de l'article | 12.1 livres |
| Quoitage | 628 watts |
| Amprage | 5.23 Amps |
| Voltage | 120 volts |
| Type de filtre | HEPA Filter (99.97% at .3 micron) |
| Capacité | 1 gallon (filter) |
| Longueur du tuyau | 1.8 mètres (environ 5.9 pieds) |
| Niveau de bruit | 70 dB |
| Caractéristiques spéciales | Portable, corded, HEPA filtration, Bagless |
| Méthode de contrôle | Voix (Note: This specification from source data may refer to a feature not typically associated with this type of vacuum, likely a manual switch) |
| Code UPC | 838067000486 |
9. Garantie et assistance
9.1 Informations sur la garantie
Atrix products are manufactured to high-quality standards. For specific warranty details regarding your Atrix Omega Green Supreme vacuum, please refer to the warranty card included with your purchase or visit the official Atrix webConsultez le site. Conservez votre reçu d'achat comme preuve d'achat pour toute réclamation au titre de la garantie.
9.2 Assistance clientèle
If you encounter any issues not covered in the troubleshooting section or require further assistance, please contact Atrix customer support. Contact information can typically be found on the Atrix website ou sur l'emballage du produit.
You can also find a digital version of the user manual here: Atrix Omega Green Supreme User Manual (PDF)
10. Vidéos produits
Aucune vidéo officielle du vendeur n'était disponible pour ce produit dans les données disponibles.