Gentex GEC3-24WR

Gentex GEC3-24WR Evacuation Horn & Strobe Instruction Manual

Model: GEC3-24WR | Brand: Gentex

1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of the Gentex GEC3-24WR, a red, wall-mount selectable-candela 24VDC horn/strobe. This device is designed for use in fire alarm systems to provide both audible and visual evacuation signals.

2. Consignes de sécurité

Always adhere to local and national electrical codes and regulations during installation and maintenance. Disconnect power before servicing the device. Only qualified personnel should perform installation and maintenance procedures. Failure to follow these instructions may result in property damage, serious injury, or death.

3. Produit terminéview

The Gentex GEC3-24WR is a low-profile evacuation horn and strobe combination unit. Key features include:

  • Pre-wire entire system, then install signals.
  • Ease of Supervision Testing (Super-Slide).
  • Checkmate Feature: Instant Voltage Verification.
  • Lower installation and operating costs.
  • Input Terminals: 12 to 18 AWG.
  • Switch Selection for High or Low dBA.
  • Switch Selection for High or Low Frequency (1500-3000Hz).
  • Switch for Temporal 3, Chime, or Whoop Tones.
  • Tamperproof Re-entrant Grill.
  • Surface Mount with the GSB (Gentex Surface Mount Box).
  • Synchronize Strobe and/or Horn by Using Gentex Synchronization Module.
Devant view of the Gentex GEC3-24WR evacuation horn and strobe with a red faceplate.

Figure 1 : Face avant view of the Gentex GEC3-24WR unit, showing the red faceplate, horn grille, and clear strobe lens. A small window on the left displays the candela setting.

Close-up of the Gentex GEC3-24WR showing the candela setting of 15.

Figure 2: Close-up of the Gentex GEC3-24WR, highlighting the selectable candela setting, currently set to 15.

4. Configuration et installation

4.1 Montage

The GEC3-24WR is designed for wall mounting. Ensure the mounting surface is flat and secure. For surface mounting, use the optional Gentex Surface Mount Box (GSB).

4.2 Câblage

The device accepts 12 to 18 AWG input terminals. Follow the wiring diagram provided with the unit and adhere to all applicable electrical codes. The unit features a 'Super-Slide' for ease of supervision testing and a 'Checkmate' feature for instant voltage vérification.

Product packaging for Gentex GEC3-24WR, showing model number 904-1317-002 and UPC 700217023983.

Figure 3: Product packaging, indicating model number 904-1317-002 and UPC 700217023983, essential for identification and compatibility.

5. Mode d'emploi

The GEC3-24WR offers selectable settings for both its horn and strobe functions. These settings are typically configured during installation based on system requirements and local codes.

5.1 Candela Selection

The strobe candela can be selected from multiple options, including 15, 30, 60, 75, and 110. Use the selector switch located on the unit to set the desired candela output.

5.2 Horn Tone and dBA Selection

The horn offers various tone patterns and sound levels:

  • Tone Patterns: Temporal 3, Chime, or Whoop.
  • Fréquence: High or Low (1500-3000Hz).
  • dBA Level: High or Low.

Refer to the internal switches for adjusting these settings according to your fire alarm system's specifications.

Synchronisation 5.3

For synchronized operation of multiple strobes and/or horns, a Gentex Synchronization Module is required. Consult the synchronization module's manual for proper integration.

Product packaging for Gentex GEC3-24WR, highlighting key features like selectable candela and multiple tones.

Figure 4: Product packaging emphasizing the unit's field-selectable candela and six field-selectable tones, including Chime and Whoop.

6. Entretien

Regular maintenance ensures the reliable operation of your Gentex GEC3-24WR. Perform periodic supervision testing as recommended by local codes and the fire alarm system manufacturer. The unit features a tamperproof re-entrant grill, which should not be removed or altered.

7. Dépannage

If the device fails to operate as expected, first verify that power is supplied correctly and that all wiring connections are secure. Check the candela and tone settings to ensure they match the system requirements. If issues persist, consult a qualified fire alarm technician.

8. Spécifications

FonctionnalitéDétail
MarqueGentex
Numéro de modèleGEC3-24WR (OEM Part Number: 904-1317-002)
CouleurRouge
Voltage24 volts CC
Quoitage24.00
Dimensions de l'article (L x l x H)2.5 x 5 x 4.5 pouces
Poids de l'article1.05 livres
Type d'ajustementAjustement universel
StyleGril
Code UPC700217023983

9. Informations sur la garantie

For specific warranty details, please refer to the documentation included with your product or contact Gentex customer support. General warranty terms typically cover manufacturing defects for a specified period from the date of purchase.

10. Assistance

For technical assistance, troubleshooting, or further information regarding your Gentex GEC3-24WR, please visit the official Gentex website or contact their customer support department. Ensure you have your product model number (GEC3-24WR) and any relevant purchase information available when seeking support.

Documents connexes - GEC3-24WR

Préview Manuel d'utilisation des dispositifs de signalisation sonore et visuelle Gentex GEC3-12, GES3-12, GEH12
Manuel d'utilisation des dispositifs de signalisation sonore et visuelle Gentex séries GEC3-12, GES3-12 et GEH12. Ce manuel couvre l'installation, le câblage, le fonctionnement, le dépannage et la garantie des systèmes d'alarme incendie.
Préview Détecteurs de fumée Gentex 7139CS et 7139LS : Manuel d’installation et d’utilisation
Guide complet d'installation et d'utilisation des détecteurs de fumée photoélectriques Gentex 7139CS et 7139LS. Ce guide inclut des informations de sécurité, le câblage, le montage, l'entretien et le dépannage pour une utilisation commerciale et résidentielle.
Préview Manuel d'installation et d'utilisation du détecteur de fumée photoélectrique Gentex série 8000
Instructions d'installation et informations destinées au propriétaire des détecteurs de fumée photoélectriques Gentex série 8000 pour systèmes en espace ouvert. Ce document couvre les modèles 8240, 8243, 8100 et 8103, leurs spécifications, leur fonctionnement, les recommandations d'installation selon la norme NFPA 72, ainsi que les modalités d'installation, d'entretien et de garantie.
Préview Guide d'installation, d'utilisation et de garantie du miroir à affichage complet Gentex
Guide complet d'installation, d'utilisation et de dépannage du Gentex Full Display Mirror (FDM). Comprend des étapes détaillées, des explications sur les fonctionnalités et une garantie limitée de 36 mois offerte par Voxx Electronics Corporation.
Préview Guide d'installation du rétroviseur à atténuation automatique Gentex avec boussole et température
Instructions d'installation complètes pour le rétroviseur à atténuation automatique Gentex avec boussole et thermomètre (modèle ADVGEN20A) de VOXX Corporation. Ce guide décrit le contenu du kit, les outils nécessaires, l'installation détaillée étape par étape, le câblage, les tests, le réglage de la boussole, les fonctions de température et le dépannage.
Préview Spécifications et applications des détecteurs de fumée photoélectriques Gentex séries 8000/8003
Informations détaillées sur les détecteurs de fumée photoélectriques Gentex séries 8000/8003 : applications, caractéristiques standard, liste des produits, conformité, spécifications électriques et schémas de câblage. Conviennent aux applications commerciales, industrielles, résidentielles et institutionnelles.