Introduction
The Rheem SP11698 Electric Thermostat is designed for use in residential electric water heaters. This unit provides reliable temperature control and features a high-limit safety mechanism to prevent overheating. Proper installation and operation are crucial for safety and optimal performance.
Informations importantes sur la sécurité
Please read and understand all instructions before installing or operating this thermostat. Failure to follow these instructions could result in property damage, personal injury, or death.
- Débrancher l'alimentation : Always turn off the main power supply to the water heater at the circuit breaker or fuse box before performing any installation, maintenance, or troubleshooting.
- Personnel qualifié: Installation and servicing of this thermostat should only be performed by a qualified electrician or plumber.
- Température de l'eau : Be aware that water temperatures above 125°F (52°C) can cause severe burns or scalding. Exercise caution when setting the thermostat.
- Câblage approprié : Assurez-vous que tous les raccordements électriques sont sécurisés et conformes aux normes électriques locales.
- Mise à la terre : The water heater and all electrical components must be properly grounded.
Installation
Avant de commencer
- Ensure the water heater is completely drained and depressurized if replacing elements or performing extensive work.
- Turn off all power to the water heater at the main electrical panel. Verify power is off using a voltage testeur.
- Remove the access panels and insulation covering the existing thermostat.
- Take a clear photograph of the existing wiring connections before disconnecting any wires. This will serve as a reference.
Instructions de câblage
The Rheem SP11698 thermostat is designed for straightforward replacement. Carefully disconnect the wires from the old thermostat, noting their positions. Connect the wires to the new Rheem SP11698 thermostat in the exact same configuration. Refer to the wiring diagram below for contact configuration details.

This diagram illustrates the internal contact configuration for both the High Limit and Thermostat sections. 'C' denotes Common, 'NC' denotes Normally Closed, and 'NO' denotes Normally Open. Contacts open when the temperature is above the setpoint. The manual reset feature is also indicated for the High Limit.
After wiring, ensure the thermostat is securely mounted against the water heater tank. Replace insulation and access panels.
Produit terminéview Vidéo
Cette vidéo offre un aperçu visuelview of the Rheem SP11698 Electric Thermostat, highlighting its key features and demonstrating its physical characteristics. While not a step-by-step installation guide, it offers helpful context for understanding the product.
Opération
Once installed and power is restored, the thermostat will begin regulating the water temperature. The Rheem SP11698 features a temperature control dial for setting the desired water temperature and a high-limit safety reset.
- Réglage de la température : Adjust the temperature dial to your preferred setting. It is recommended to set the temperature between 120°F (49°C) and 125°F (52°C) to balance comfort and energy efficiency while minimizing scalding risk.
- High-Limit Reset: If the water temperature exceeds a safe limit, the high-limit switch will trip, cutting power to the heating elements. To reset, press the red manual reset button located on the thermostat. If the high-limit trips repeatedly, consult a qualified technician to diagnose the underlying issue.
Entretien
Regular maintenance helps ensure the longevity and efficient operation of your water heater and thermostat.
- Inspection annuelle: Have a qualified technician inspect your water heater and its components, including the thermostat, annually.
- Vérifier les connexions : Periodically, with power disconnected, check all electrical connections to the thermostat and heating elements to ensure they are tight and free from corrosion.
- Gardez la zone dégagée : Veillez à ce que la zone autour du chauffe-eau soit dégagée de tout obstacle et de tout matériau inflammable.
Dépannage
If you experience issues with your water heater, the thermostat may be a factor. Always disconnect power before inspecting components.
| Problème | Cause possible | Solution |
|---|---|---|
| Pas d'eau chaude | High-limit switch tripped | Press the red manual reset button. If it trips again, investigate further. |
| Pas d'eau chaude | Panne du thermostat | Test thermostat for continuity. Replace if faulty. |
| Eau trop chaude/froide | Mauvais réglage de la température | Réglez le cadran de température sur le réglage souhaité. |
| Eau trop chaude/froide | Thermostat défectueux | Test thermostat for proper operation. Replace if temperature regulation is inconsistent. |
For persistent issues or if you are unsure about any troubleshooting steps, contact a qualified service technician.
Caractéristiques
| Fonctionnalité | Détail |
|---|---|
| Marque | Rheem |
| Nom du modèle | Rheem SP11698 Electric Thermostat |
| Numéro de pièce | SP11698 |
| Dimensions du produit | 2"P x 3.6"L x 2"H |
| Type de contrôleur | Touche |
| Dossier spécial | High-Limit Protection |
| Couleur | Noir |
| Utilisations spécifiques du produit | Chauffe-eau |
| Type de contrôle de température | Numérique |
| Source d'énergie | Électrique avec fil |
| Voltage | 220 volts |
| Poids de l'article | 5.6 onces |
| Code UPC | 020352381794 |
Garantie et assistance
For specific warranty information regarding your Rheem SP11698 Electric Thermostat, please refer to the documentation included with your purchase or visit the official Rheem website. If you require technical assistance, replacement parts, or have questions not covered in this manual, please contact Rheem customer support directly.
Service client Rheem : S'il vous plaît visitez www.rheem.com/support pour obtenir des informations de contact et des ressources supplémentaires.