1. Introduction et plusview

The Altronix 6062 Multi-Function Timer is a versatile programmable timer designed for various applications requiring precise timing control. It operates on either 12VDC or 24VDC and features SPDT (Single Pole Double Throw) contacts rated at 8 amp/115VAC. This unit offers an adjustable timing range from 1 second to 60 minutes, with a unique capability to provide a momentary relay activation at the conclusion of a set timing cycle.

This manual provides essential information for the proper installation, operation, and maintenance of your Altronix 6062 Multi-Function Timer.

2. Caractéristiques

  • Multi-function programmable timer.
  • Flexible power input: 12VDC or 24VDC operation.
  • High-capacity SPDT contacts rated at 8 amp/115VAC.
  • Wide adjustable timing range: 1 second to 60 minutes.
  • Features momentary relay activation at the end of the timing cycle.
  • Conception compacte et durable.
  • Fait dans le U.S.A.
  • Conforme RoHS.

3. Configuration et installation

Informations importantes sur la sécurité : Installation should be performed by qualified personnel in accordance with all local and national electrical codes. Disconnect all power before installation or servicing.

3.1. Montage

Mount the Altronix 6062 timer in a secure, dry location, away from excessive heat or moisture. Ensure adequate ventilation around the unit.

3.2. Câblage

The Altronix 6062 timer requires a 12VDC or 24VDC power source. Connect the power supply to the designated input terminals, observing correct polarity. The unit features SPDT contacts for controlling external devices. Wire your load to the Normally Open (NO) or Normally Closed (NC) contacts and the Common (C) terminal as required by your application. Refer to the product's included wiring diagram for specific connection points.

Altronix 6062 Multi-Function Timer product packaging

Image of the Altronix 6062 Multi-Function Timer in its blue and white retail box, displaying the model number, key features, and Altronix branding.

4. Mode d'emploi

4.1. Setting the Timing Range

The Altronix 6062 allows for an adjustable timing range from 1 second to 60 minutes. The timing duration is typically set via an onboard potentiometer or dip switches. Carefully adjust the setting to achieve the desired delay for your application. Test the timing repeatedly to ensure accuracy.

4.2. Momentary Relay Activation

This timer includes a feature for momentary relay activation at the completion of the set timing cycle. This can be utilized to trigger a brief event or signal after the primary delay has elapsed. Consult the specific wiring and configuration details provided with your unit for enabling and utilizing this function.

5. Entretien

The Altronix 6062 Multi-Function Timer is designed for reliable, maintenance-free operation under normal conditions. To ensure optimal performance and longevity:

  • Inspectez périodiquement tous les branchements électriques pour vous assurer qu'ils sont bien fixés et exempts de corrosion.
  • Keep the unit free from dust, dirt, and debris. Use a soft, dry cloth for cleaning.
  • Do not expose the unit to extreme temperatures, humidity, or direct water contact.
  • N'essayez pas d'ouvrir le casing or service internal components. Refer all servicing to qualified personnel.

6. Dépannage

If you encounter issues with your Altronix 6062 Multi-Function Timer, consider the following troubleshooting steps:

  • No Power/Unit Not Functioning:
    • Verify that the correct DC input voltage (12VDC or 24VDC) is applied to the power terminals.
    • Check for correct power supply polarity.
    • Assurez-vous que toutes les connexions électriques sont bien fixées.
  • Incorrect Timing/Relay Not Activating:
    • Re-adjust the timing potentiometer or settings to the desired duration.
    • Confirm that the load connected to the SPDT contacts is within the specified 8 amp/115VAC rating.
    • Check all load wiring connections for security and continuity.
    • Ensure the timing cycle is completing as expected before the relay is supposed to activate.

For persistent issues or problems not covered here, please contact Altronix technical support.

7. Spécifications

AttributDétail
FabricantSociété Altronix
Numéro de pièce6062
Numéro de modèle de l'article6062SP
Puissance d'entrée12 V CC ou 24 V CC
Type de contactSPDT (Single Pole Double Throw)
Contacter Notation8 amp/115 VCA
Plage de temps1 seconde à 60 minutes
Poids de l'article2.08 onces
Dimensions du produit1 x 1 x 1 pouces
MatérielFibre de verre
Date de première disponibilité25 juillet 2010
Conforme RoHSOui

8. Garantie et assistance

Altronix products are engineered for superior performance and reliability. The Altronix 6062 Multi-Function Timer is backed by a Garantie à vie, ensuring long-term peace of mind.

For technical support, warranty claims, or additional product information, please visit the official Altronix webconsultez leur site ou contactez leur service client :

Website: altronix.com

Please have your product model number (6062) and any relevant purchase information ready when contacting support.

Documents connexes - 6062

Préview Altronix RBST Relay Module: Specifications and Wiring Configurations
Detailed specifications and wiring diagrams for the Altronix RBST Relay Module, covering dry contacts, polarity reversal, latching dry contacts, and line seizure applications. Includes product information and contact details.
Préview Module relais Altronix RB30 : Spécifications et fonctionnement
Spécifications détaillées et instructions de fonctionnement du module relais Altronix RB30, avec fonctionnement 12VDC/24VDC, contacts 30A et homologation UL.
Préview Altronix 6062 Multi-purpose Timer: Installation and Application Guide
Detailed guide for the Altronix 6062 Multi-purpose Timer, covering specifications, installation instructions, dip switch and jumper settings, terminal identification, and typical applications for access control, security systems, and automation.
Préview Spécifications et câblage du module relais Altronix RBSN
Spécifications détaillées et schémas de câblage du module relais Altronix RBSN, y compris le fonctionnement, les contacts et le montage.
Préview Altronix SMP7 Power Supply/Charger Installation Guide
Installation guide for the Altronix SMP7, a 12VDC or 24VDC selectable output power supply and charger with a 6A continuous supply current, featuring battery backup and LED diagnostics.
Préview Module relais Altronix RB5 : Spécifications et schémas d’application
The Altronix RB5 Relay Module offers selectable 6VDC or 12VDC operation with 5A DPDT contacts. It supports Dry Contacts, Polarity Reversal, Latching Dry Contacts, and Line Seizure applications, ideal for security and control systems. Snap track mountable.