Introduction
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Kanlux Merge JQ-O 360° motion detector. Please read these instructions carefully before use and retain them for future reference.
Informations importantes sur la sécurité
- L'installation doit être effectuée par un électricien qualifié, conformément à toutes les normes électriques locales et nationales.
- Disconnect power at the circuit breaker before installation, maintenance, or troubleshooting.
- Do not exceed the maximum load capacity of 2000 W (active) / 600 W (inductive).
- Cet appareil est conçu pour une utilisation en intérieur uniquement.
- Assurez-vous d’une mise à la terre appropriée pour éviter les chocs électriques.
Produit terminéview
The Kanlux Merge JQ-O is a recessed 360° motion detector designed to automatically switch lighting or other electrical loads based on detected movement and ambient light levels. Its compact design and white plastic housing make it suitable for various indoor applications.
Caractéristiques principales :
- Recessed mounting for discreet integration.
- 360° horizontal detection angle.
- Adjustable operating time from 5 seconds to 6 minutes.
- Adjustable ambient light intensity threshold.
- Maximum detection range of 5 meters.
- White plastic housing.
Spécifications techniques
| Paramètre | Valeur |
|---|---|
| Numéro de modèle | 7691 |
| Alimentation électrique | 220 Volts, Wired Electrically |
| Max. Active Load | 2000 W |
| Max. Charge inductive | 600 W |
| Angle de détection (horizontal) | 360° |
| Angle de détection (vertical) | 120° |
| Max. Portée de détection | 5 mètres |
| Adjustable Operating Time | 5 secondes à 6 minutes |
| Intensité lumineuse réglable | Oui |
| Type de montage | Encastré |
| Couleur | Blanc |
| Matériau du boîtier | Plastique |
| Dimensions du produit (L x l x H) | 1 x 1 x 1 cm (119 grammes) |
| Recessed Cutout Diameter | 65 mm (as per description) / 62 mm (as per diagram) - Please refer to diagram for precise measurements. |
| Recessed Depth | 73 mm (as per diagram) |
Installation et configuration
Before beginning installation, ensure the main power supply is disconnected at the circuit breaker.
1. Emplacement de montage
Choose a suitable indoor location for recessed mounting. Avoid placing the detector near heat sources, air conditioning vents, or areas with direct sunlight, as these can cause false triggers. The optimal mounting height is typically between 2.2m and 4m for effective detection.
2. Prepare the Mounting Hole
Create a circular cutout in the ceiling or wall according to the specified dimensions. Refer to the diagram below for precise measurements.

Figure 1: Kanlux Merge JQ-O Motion Detector Dimensions
This diagram illustrates the physical dimensions of the motion detector, including the required cutout size for recessed installation. The total depth is 73mm. The visible front ring has a diameter of 76mm, with the sensor lens having a diameter of 50mm. The main body for recessing has a diameter of 62mm. The recommended installation hole diameter is 65mm.
- Recessed Cutout Diameter: Ø65mm (as per product description) or Ø62mm (as per diagram for the body). The diagram also shows Ø76mm for the outer ring. Use Ø65mm for the hole.
- Profondeur d'encastrement : 73mm.
3. Câblage
Connect the detector to the 220V electrical supply and the load (e.g., light fixture) according to the wiring diagram provided with the product packaging. Ensure all connections are secure and insulated. The terminals are typically marked for Live (L), Neutral (N), and Switched Live (L').
Note: The provided product information does not include a specific wiring diagram. Always refer to the diagram supplied with your physical product for correct wiring.
4. Insert the Detector
Carefully push the detector into the prepared cutout. The spring clips will secure it in place.
5. Rétablir l'alimentation
Une fois l’installation terminée, rétablissez l’alimentation au disjoncteur.
Instructions d'utilisation et réglages
The Kanlux Merge JQ-O motion detector features adjustable settings for optimal performance.
1. Time Delay Adjustment (TIME)
This knob controls how long the connected load remains ON after motion is no longer detected. The adjustable range is from 5 seconds to 6 minutes. Turn the knob clockwise to increase the time delay and counter-clockwise to decrease it.
2. Light Sensitivity Adjustment (LUX)
This knob determines the ambient light level at which the detector will become active.
- Turn towards the "sun" symbol for activation only in bright conditions (e.g., daytime).
- Turn towards the "moon" symbol for activation in low light conditions (e.g., nighttime).
3. Detection Area
The detector has a 360° horizontal and 120° vertical detection angle with a maximum range of 5 meters. Test the detection area after installation to ensure it covers the desired space. Walk through the area to observe when the detector triggers.
Entretien
- Nettoyage: Gently wipe the sensor lens with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Inspection: Vérifiez régulièrement l'absence de dommages visibles ou de connexions desserrées.
- Aucune pièce réparable par l'utilisateur : The device contains no user-serviceable parts. Do not attempt to open or repair the unit yourself. Refer all servicing to qualified personnel.
Dépannage
| Problème | Cause possible | Solution |
|---|---|---|
| La lumière ne s'allume pas lorsqu'un mouvement est détecté. |
|
|
| La lumière reste allumée en permanence ou s'allume de façon aléatoire. |
|
|
| La portée de détection est trop courte. |
|
|
If you encounter issues not listed here or if problems persist after attempting the suggested solutions, please contact Kanlux customer support.
Garantie et support client
Kanlux products are manufactured to high-quality standards. For information regarding warranty terms and conditions, please refer to the documentation provided with your purchase or visit the official Kanlux website. For technical assistance or support, please contact your retailer or Kanlux customer service directly.
Kanlux Officiel Website: www.kanlux.com