Introduction

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Kanlux Merge JQ-O 360° motion detector. Please read these instructions carefully before use and retain them for future reference.

Informations importantes sur la sécurité

Produit terminéview

The Kanlux Merge JQ-O is a recessed 360° motion detector designed to automatically switch lighting or other electrical loads based on detected movement and ambient light levels. Its compact design and white plastic housing make it suitable for various indoor applications.

Caractéristiques principales :

Spécifications techniques

ParamètreValeur
Numéro de modèle7691
Alimentation électrique220 Volts, Wired Electrically
Max. Active Load2000 W
Max. Charge inductive600 W
Angle de détection (horizontal)360°
Angle de détection (vertical)120°
Max. Portée de détection5 mètres
Adjustable Operating Time5 secondes à 6 minutes
Intensité lumineuse réglableOui
Type de montageEncastré
CouleurBlanc
Matériau du boîtierPlastique
Dimensions du produit (L x l x H)1 x 1 x 1 cm (119 grammes)
Recessed Cutout Diameter65 mm (as per description) / 62 mm (as per diagram) - Please refer to diagram for precise measurements.
Recessed Depth73 mm (as per diagram)

Installation et configuration

Before beginning installation, ensure the main power supply is disconnected at the circuit breaker.

1. Emplacement de montage

Choose a suitable indoor location for recessed mounting. Avoid placing the detector near heat sources, air conditioning vents, or areas with direct sunlight, as these can cause false triggers. The optimal mounting height is typically between 2.2m and 4m for effective detection.

2. Prepare the Mounting Hole

Create a circular cutout in the ceiling or wall according to the specified dimensions. Refer to the diagram below for precise measurements.

Technical diagram showing dimensions of the Kanlux Merge JQ-O motion detector. The diagram shows a side view et une façade view. Key dimensions include a total height of 73mm, a recessed body diameter of 62mm, a front face diameter of 76mm, and a visible sensor diameter of 50mm. The cutout diameter is indicated as 65mm.

Figure 1: Kanlux Merge JQ-O Motion Detector Dimensions

This diagram illustrates the physical dimensions of the motion detector, including the required cutout size for recessed installation. The total depth is 73mm. The visible front ring has a diameter of 76mm, with the sensor lens having a diameter of 50mm. The main body for recessing has a diameter of 62mm. The recommended installation hole diameter is 65mm.

3. Câblage

Connect the detector to the 220V electrical supply and the load (e.g., light fixture) according to the wiring diagram provided with the product packaging. Ensure all connections are secure and insulated. The terminals are typically marked for Live (L), Neutral (N), and Switched Live (L').

Note: The provided product information does not include a specific wiring diagram. Always refer to the diagram supplied with your physical product for correct wiring.

4. Insert the Detector

Carefully push the detector into the prepared cutout. The spring clips will secure it in place.

5. Rétablir l'alimentation

Une fois l’installation terminée, rétablissez l’alimentation au disjoncteur.

Instructions d'utilisation et réglages

The Kanlux Merge JQ-O motion detector features adjustable settings for optimal performance.

1. Time Delay Adjustment (TIME)

This knob controls how long the connected load remains ON after motion is no longer detected. The adjustable range is from 5 seconds to 6 minutes. Turn the knob clockwise to increase the time delay and counter-clockwise to decrease it.

2. Light Sensitivity Adjustment (LUX)

This knob determines the ambient light level at which the detector will become active.

Adjust this setting to prevent the light from turning on unnecessarily during daylight hours.

3. Detection Area

The detector has a 360° horizontal and 120° vertical detection angle with a maximum range of 5 meters. Test the detection area after installation to ensure it covers the desired space. Walk through the area to observe when the detector triggers.

Entretien

Dépannage

ProblèmeCause possibleSolution
La lumière ne s'allume pas lorsqu'un mouvement est détecté.
  • No power to the detector.
  • LUX setting is too high (daylight mode).
  • Erreur de câblage.
  • Motion not within detection range/angle.
  • Vérifiez le disjoncteur et l'alimentation électrique.
  • Adjust LUX setting towards "moon" symbol.
  • Vérifiez les connexions de câblage (coupez l'alimentation au préalable).
  • Adjust detector position or test detection area.
La lumière reste allumée en permanence ou s'allume de façon aléatoire.
  • Le réglage de la durée est trop long.
  • Mouvement constant dans la zone de détection.
  • Interference from heat sources or air currents.
  • Appareil défectueux.
  • Réduisez la durée en ajustant le paramètre TIME.
  • Ensure no constant movement.
  • Relocate detector away from interference.
  • Contactez le service client si le problème persiste.
La portée de détection est trop courte.
  • Obstructions bloquant le capteur.
  • Hauteur de montage incorrecte.
  • Éliminez tous les obstacles.
  • Ensure mounting height is within recommended range (2.2m - 4m).

If you encounter issues not listed here or if problems persist after attempting the suggested solutions, please contact Kanlux customer support.

Garantie et support client

Kanlux products are manufactured to high-quality standards. For information regarding warranty terms and conditions, please refer to the documentation provided with your purchase or visit the official Kanlux website. For technical assistance or support, please contact your retailer or Kanlux customer service directly.