Altronix R2416300UL

Manuel d'utilisation de l'alimentation rackable Altronix R2416300UL

Model: R2416300UL

1. Introduction

The Altronix R2416300UL is a rack mount power supply designed to provide 24VAC or 28VAC power for various applications, particularly commercial CCTV equipment. This unit features 16 individually fused outputs, ensuring reliable power distribution and protection. It is housed in a durable steel enclosure and includes a line cord, spare fuse, removable terminal blocks, and mounting brackets for convenient installation.

2. Informations importantes sur la sécurité

Please read these safety instructions carefully before installing or operating the Altronix R2416300UL power supply. Failure to follow these instructions may result in electric shock, fire, or damage to the unit.

Altronix R2416300UL Rack Mount Power Supply Front View

Figure 1 : Face avant view of the Altronix R2416300UL Rack Mount Power Supply. This image shows the black steel enclosure with the Altronix logo and 16 green LED indicators for each output. A caution label for electric shock is visible on the right.

3. Configuration et installation

3.1. Déballage

Carefully remove the power supply from its packaging. Verify that all components are present: the R2416300UL unit, line cord, spare fuse, removable terminal blocks, and mounting brackets.

3.2. Montage

The R2416300UL is designed for rack mounting. Use the provided mounting brackets to secure the unit into a standard 19-inch equipment rack. Ensure the rack is stable and provides adequate support for the unit's weight (approximately 17.2 pounds).

3.3. Input Power Connection

  1. Assurez-vous que l'interrupteur d'alimentation situé à l'arrière de l'appareil est en position « ARRÊT ».
  2. Connect the supplied line cord to the AC input receptacle on the rear of the power supply.
  3. Plug the other end of the line cord into a grounded 115VAC, 60Hz power outlet.
Altronix R2416300UL Rack Mount Power Supply Rear View

Figure 2 : Arrière view of the Altronix R2416300UL Rack Mount Power Supply. This image displays the power switch, AC input, and the array of 16 output terminal blocks. The product label with specifications is also visible.

3.4. Connexions de sortie

The R2416300UL provides 16 individually fused 24VAC or 28VAC outputs. Each output is equipped with a removable terminal block for easy wiring.

  1. Identify the desired output terminal block (labeled 1 through 16).
  2. Connect your device's power input wires to the corresponding terminals on the removable block. Ensure correct polarity if applicable to your device.
  3. Securely insert the wired terminal block into its receptacle on the power supply.
  4. Repeat for all devices requiring power.
Altronix R2416300UL Rear Label and Terminal Blocks Close-up

Figure 3: Close-up of the rear product label and output terminal blocks. This image provides a detailed view of the product specifications, safety warnings, and the green removable terminal blocks for connecting output devices.

4. Mode d'emploi

4.1. Mise sous/hors tension

4.2. Output Indicators

The front panel of the R2416300UL features 16 green LED indicators, one for each output. A lit green LED indicates that the corresponding output is receiving power and the fuse is intact.

Altronix R2416300UL Front Panel LED Indicators Close-up

Figure 4: Close-up of the front panel showing the 16 green LED indicators. Each LED corresponds to an individual fused output, providing a visual status of power delivery.

5. Entretien

5.1. Soins généraux

5.2. Remplacement du fusible

If an output LED is off, the corresponding fuse may be blown. To replace a fuse:

  1. Éteindre: Disconnect the unit from the main power supply by unplugging the line cord.
  2. Identify Blown Fuse: Locate the fuse holder for the affected output on the rear panel.
  3. Remove Fuse: Retirez soigneusement le fusible grillé.
  4. Install New Fuse: Replace it with a new fuse of the exact same type and rating: 3.5A, 250V. Using an incorrect fuse can cause damage or fire.
  5. Restaurer l'alimentation : Reconnect the unit to the main power supply and turn it on. Verify the output LED illuminates.

6. Dépannage

ProblèmeCause possibleSolution
No power to the unit (no LEDs lit).
  • Cordon d'alimentation non branché.
  • Pas de courant à la prise.
  • Défaut interne.
  • Assurez-vous que le cordon d'alimentation est bien branché.
  • Tester la prise avec un autre appareil.
  • Contact Altronix technical support.
One or more output LEDs are off.
  • Blown fuse for that output.
  • Short circuit or overload on the output.
  • Replace the fuse (3.5A, 250V).
  • Check the connected device for faults or excessive current draw.
Unit powers on, but connected devices do not function.
  • Câblage incorrect.
  • Panne de l'appareil.
  • Volume de sortietage décalage.
  • Vérifiez que toutes les connexions sont correctes.
  • Test device with another power source if possible.
  • Confirm device requires 24VAC or 28VAC.

7. Spécifications

FonctionnalitéDétail
MarqueAltronix
Numéro de modèleR2416300UL
Vol d'entréetage115VAC (Minimum 110V, Maximum 115V)
Fréquence d'entrée60 Hz
Volume de sortietage24 VCA ou 28 VCA
Output Current (24VAC)12.5A
Output Current (28VAC)10A
Number of Fused Outputs16
Type/valeur nominale du fusible3.5A, 250V
Facteur de formeRack Mount
Matériau de l'enceinteAcier
FinitionNoir
Dimensions du produit (L x l x H)19.13 x 8.5 x 3.27 pouces
Poids de l'article17.2 livres
NormesUL 2044 Commercial CCTV, CUL, CE
Méthode de refroidissementAir

8. Garantie et assistance

8.1. Informations sur la garantie

Altronix products are typically backed by a limited lifetime warranty. For specific warranty terms and conditions applicable to your R2416300UL unit, please refer to the official Altronix webConsultez le site ou contactez directement leur service client. Conservez votre reçu d'achat comme preuve d'achat.

8.2. Assistance technique

For technical assistance, installation questions, or troubleshooting beyond the scope of this manual, please contact Altronix technical support. You can find their contact information on the official Altronix website (www.altronix.com).

Documents connexes - R2416300UL

Préview Guide d'installation des alimentations CCTV série Altronix ALTV244UL
Installation guide for Altronix ALTV244UL series CCTV power supplies, detailing models, specifications, installation instructions, and enclosure dimensions. Features 24VAC/28VAC outputs with fuse or PTC protection for CCTV cameras and video accessories.
Préview Guide d'installation des alimentations CCTV montées sur rack Altronix VertiLine24 Series
Comprehensive installation guide for Altronix VertiLine24 Series CCTV Rack Mount Power Supplies, covering models VertiLine24, VertiLine246, VertiLine24D, and VertiLine246D. Includes specifications, detailed installation instructions, mounting options, safety warnings, and troubleshooting tips.
Préview Altronix ALTV2432 Series 32-Output CCTV Power Supply Installation Guide
Installation guide for the Altronix ALTV2432 Series 32-output CCTV power supplies, detailing models, specifications, and installation instructions for 24VAC and 28VAC operation.
Préview Guide d'installation des alimentations CCTV à 2416 sorties Altronix ALTV16 Series
Installation guide for Altronix ALTV2416 Series 16-Output CCTV Power Supplies, detailing models, specifications, features, installation instructions, terminal identification, and enclosure dimensions.
Préview Altronix ALTV1224DC220 Series CCTV Power Supplies Installation Guide
Installation guide for Altronix ALTV1224DC220 Series CCTV Power Supplies, covering model details, specifications, terminal identification, and safety instructions for powering CCTV cameras and accessories.
Préview Guide d'installation de l'alimentation à double sortie Altronix ALTV1224C4220 AC/DC
Installation guide for the Altronix ALTV1224C4220 AC/DC Dual Output Power Supply, detailing specifications, installation steps, fuse replacement, and terminal identification for providing 12VDC and 24VAC outputs.