ABB RC5

ABB RC5-1/250 Surge Suppressor User Manual

Model: RC5-1/250 | Part Number: 1SBN050100R1002

1. Introduction

This manual provides essential information for the safe and effective installation, operation, and maintenance of the ABB RC5-1/250 Surge Suppressor. Please read this manual thoroughly before using the product and retain it for future reference.

The ABB RC5-1/250 is designed to protect electrical equipment from transient overvoltages, ensuring reliable performance and extending the lifespan of connected devices. It is suitable for use with N, A9...A40, AS, NS series contactors and motor starters.

2. Consignes de sécurité

AVERTISSEMENT: Electrical shock hazard. Installation and maintenance should only be performed by qualified personnel. Disconnect power before installation or servicing.

Observe all local and national electrical codes. Failure to follow these instructions may result in serious injury or death.

3. Produit terminéview

The ABB RC5-1/250 is a compact surge suppressor designed for easy integration with ABB control devices. Its primary function is to absorb transient voltage spikes, protecting sensitive electronic components.

ABB RC5-1/250 Surge Suppressor, top-side view

Figure 3.1 : Face supérieure view of the ABB RC5-1/250 Surge Suppressor. The image shows the grey rectangular body with two metal prongs extending from the bottom. Markings on the top surface include "ABB", "RC5-1/250", "110-250V~", UL and CE certifications, and "Use with: N, A9...A40, AS, NS".

Caractéristiques principales :

4. Configuration et installation

The RC5-1/250 surge suppressor is designed for simple, direct mounting onto compatible ABB contactors and motor starters.

  1. Coupure de courant : Ensure all power to the control circuit and associated equipment is disconnected and locked out before beginning installation. Verify with a voltage testeur.
  2. Identifier l'emplacement de montage : Locate the designated top or side mounting slots on your ABB N, A9...A40, AS, or NS series contactor or motor starter.
  3. Insert Suppressor: Align the prongs of the RC5-1/250 suppressor with the corresponding slots on the contactor. Gently push the suppressor firmly into place until it clicks or is securely seated. Ensure a proper electrical connection is made.
  4. Vérifiez la connexion : Visually inspect the installed suppressor to ensure it is flush and securely attached to the contactor.
  5. Restaurer l'alimentation : Une fois l'installation terminée et vérifiée, rétablissez l'alimentation électrique du circuit.

For detailed diagrams specific to your contactor model, refer to the contactor's instruction manual.

5. Mode d'emploi

The ABB RC5-1/250 Surge Suppressor operates passively and requires no user interaction once installed. It continuously monitors the control circuit for transient overvoltages and diverts excess energy to protect the connected equipment.

Its operation is automatic and transparent to the user. The suppressor functions as a protective device, activating only when a voltage spike occurs. There are no indicators or controls on the suppressor itself.

6. Entretien

The ABB RC5-1/250 Surge Suppressor is a maintenance-free device. Regular inspection of the electrical system it protects is recommended.

Coupez toujours l'alimentation électrique avant d'effectuer toute inspection ou maintenance.

7. Dépannage

The RC5-1/250 is a passive component, and direct troubleshooting is limited. Most issues related to surge protection will manifest in the protected equipment.

ProblèmeCause possibleSolution
Protected equipment still experiences damage from voltage pointes.
  • 1. Suppressor is damaged or has reached end-of-life.
  • 2. Incorrect suppressor installed for the application.
  • 3. Surge event exceeds suppressor's capacity.
  • 4. Mauvaise installation.
  • 1. Replace the RC5-1/250 suppressor.
  • 2. Verify the suppressor's specifications match the circuit requirements.
  • 3. Consider additional surge protection measures for the entire electrical system.
  • 4. Re-check installation as per Section 4.
Suppressor appears physically damaged (e.g., cracked casing, burnt marks).Severe overvoltage event or internal failure.Immediately disconnect power and replace the suppressor. Do not attempt to repair.

If issues persist, contact a qualified electrician or ABB technical support.

8. Spécifications

ParamètreValeur
Numéro de modèleRC5-1/250
Numéro de pièce1SBN050100R1002
MarqueFIGUE
Vol d'exploitationtage110-250 V c.a., 50/60 Hz
CompatibilitéABB N, A9...A40, AS, NS series contactors/motor starters
Type de montageTop/Side Mounted
Dimensions du produit (L x l x H)9.06 x 14.57 x 12.4 inches (Packaging/Shipping dimensions, actual unit is smaller)
Poids de l'article18.3 Pounds (Shipping weight, actual unit is lighter)
CertificationsUL Listed, CE, EAC

Note: Product dimensions and weight listed are typically for shipping packaging. The actual suppressor unit is compact.

9. Garantie et assistance

For information regarding product warranty, please refer to the official ABB warranty policy available on the ABB website or contact your local ABB distributor.

For technical support, product inquiries, or service, please visit the official ABB website or contact ABB customer service through the contact information provided on their website. When contacting support, please have your product model number (RC5-1/250) and part number (1SBN050100R1002) ready.

ABB Officiel Website: www.abb.com

Documents connexes - RC5

Préview ABB Haute VoltagGuide d'achat des parafoudres : sélection et informations techniques
Guide d'achat complet d'ABB détaillant les hautes tensionstagParafoudres (PEXLIM, TEXLIM, EXLIM). Ce document décrit les spécifications techniques, les procédures de sélection, les caractéristiques de conception et les recommandations d'application pour la protection des infrastructures électriques.
Préview Produits d'électrification ABB à basse tensiontagCatalogue de produits électroniques
Catalogue complet détaillant la vaste gamme de produits à basse tension d'ABBtagProduits d'électrification, notamment disjoncteurs, solutions de comptage, infrastructures de recharge pour véhicules électriques, etc. Consultez les spécifications techniques et les informations produits.
Préview Contrôleur de robot industriel ABB IRC5 : caractéristiques, variantes et spécifications
Découvrez le contrôleur de robot industriel ABB IRC5, une solution de pointe en robotique. Ce document détaille ses principales fonctionnalités, notamment le contrôle de mouvement avancé, les fonctions de sécurité et une large compatibilité. Il présente également les différentes variantes du contrôleur IRC5 : armoire simple, compact, PMC et Paint, ainsi que leurs spécifications techniques et le matériel associé, comme le FlexPendant et RobotStudio Online.
Préview ABB Haute VoltagParafoudres : Guide d'achat complet
Ce guide d'achat d'ABB fournit des informations détaillées sur les hautes tensionstage surge arresters, including porcelain-housed (EXLIM) and silicone polymer-housed (PEXLIM) types. It covers design features, technical specifications, selection procedures, and applications for protecting electrical equipment from overvoltaget.
Préview Disjoncteur ABB Vmax : Instructions d’installation et d’entretien
Manuel complet d'installation et d'entretien pour ABB Vmax moyenne tensiontagCe document traite des disjoncteurs, notamment des modèles de 12 à 17.5 kV, de 630 à 1 250 A et de 16 à 31.5 kA. Il inclut des consignes de sécurité, des procédures d’utilisation, des informations sur la maintenance et les pièces de rechange.
Préview Actionneur de volet/store ABB i-bus KNX 4 canaux SMI LoVo REG SJR/S 4.24.2.1
Caractéristiques techniques et schéma de connexion du variateur de volets/stores SMI LoVo 4 canaux ABB i-bus KNX, modèle SJR/S 4.24.2.1. Ce dispositif commande jusqu'à quatre motorisations SMI LoVo (24 V) pour le positionnement de stores, volets, auvents et autres dispositifs de protection solaire via ABB i-bus KNX. Il est équipé de boutons de commande manuelle et de LED d'état.