1. Produit terminéview
The APC Back-UPS 350VA (model BE350G) is an Uninterruptible Power Supply (UPS) designed to provide battery backup and surge protection for your electronic devices. It ensures continuous power during outages and protects against power surges, safeguarding your computers, external hard drives, wireless routers, and other sensitive electronics.
Caractéristiques principales
- 350VA / 200W Battery Backup capacity.
- 6 Total Outlets: 3 outlets provide Battery Backup and Surge Protection; 3 outlets offer Surge Protection Only.
- Compact design for easy placement in various environments.
- Protects connected equipment from power outages, surtensions et pointes.
2. Contenu du colis
Vérifiez que votre colis contient les éléments suivants :
- APC Back-UPS 350VA (BE350G) Unit
- Manuel de l'utilisateur (ce document)
- Surge Protector (as an integrated component)
3. Installation
3.1 Déballage et installation initiale
Carefully remove the UPS from its packaging. Place the unit on a stable, flat surface, ensuring adequate ventilation around the unit. Avoid placing it near heat sources or in direct sunlight.
3.2 Connexion de la batterie
The internal battery may be disconnected for shipping. Refer to the diagram below to connect the battery before initial use. This step is crucial for the UPS to provide battery backup functionality.

Figure 1 : De haut en bas view of the APC Back-UPS 350VA (BE350G) unit. Locate the battery compartment, typically on the bottom or side of the unit, and connect the internal battery terminals as instructed in the quick start guide or on the unit itself.
3.3 Connexion à l'alimentation
Plug the UPS power cord directly into a grounded two-pole, three-wire wall outlet. Do not use extension cords, power strips, or other surge protectors with the UPS input, as this can compromise its effectiveness.
3.4 Connecter l'équipement
The BE350G features six outlets. It is important to identify the outlets providing battery backup and surge protection, and those offering surge protection only.
- Connect critical devices (e.g., computer, monitor, wireless router, external hard drives) to the three outlets labeled "Battery Backup + Surge Protection". These devices will remain powered during an outage.
- Connect non-critical devices (e.g., printer, scanner, desk lamp) to the three outlets labeled "Surge Protection Only". These devices will be protected from surges but will lose power during an outage.

Figure 2 : Côté profile of the APC Back-UPS 350VA, illustrating its dimensions and how it might fit in a workspace. Ensure proper cable management for all connected devices.
4. Fonctionnement
4.1 Mise sous/hors tension
- Pour allumer : Press and hold the power button until you hear a short beep and the "Power On" indicator (green LED) illuminates.
- Pour éteindre : Press and hold the power button again until the unit shuts down and the "Power On" indicator turns off.
4.2 Voyants lumineux
- Power On (Green LED): This indicator illuminates when the UPS is actively providing power to connected equipment.
- Replace Battery (Red LED): This indicator illuminates when the internal battery has reached the end of its service life and requires replacement.
4.3 During a Power Outage
Quand un pouvoir outage occurs, the UPS will automatically switch to battery power. It will emit an audible alarm to notify you of the power loss. During this time, it is recommended to save your work and properly shut down your computer to prevent data loss, especially if the outage est prolongé.
5. Entretien
5.1 Remplacement de la batterie
The internal battery has a limited lifespan and will eventually need replacement. When the "Replace Battery" indicator illuminates, it signifies that the battery is nearing the end of its useful life. Contact APC support or an authorized dealer for a replacement battery. Follow the instructions provided with the replacement battery for safe installation.
5.2 Nettoyage
Periodically clean the exterior of the UPS with a dry cloth. Do not use liquid cleaners or solvents, as these can damage the unit. Ensure that all ventilation openings are free from dust and debris to maintain proper airflow and prevent overheating.
6. Dépannage
6.1 UPS Does Not Turn On
- Assurez-vous que le cordon d'alimentation de l'onduleur est correctement branché dans une prise murale sous tension et mise à la terre.
- Verify that the internal battery is properly connected. Refer to Section 3.2 for battery connection instructions.
- Vérifiez le fonctionnement de la prise murale en y branchant un autre appareil.
6.2 UPS Beeps Continuously
- This typically indicates a power outage or a low battery condition. Save your work and shut down connected equipment if the power outage est prolongé.
- If the "Replace Battery" LED is illuminated, the battery needs replacement.
6.3 No Power from Battery Backup Outlets
- Confirm that devices are plugged into the "Battery Backup + Surge Protection" outlets, not the "Surge Protection Only" outlets.
- Check if the UPS is overloaded. Disconnect some non-essential devices and try again. The total wattage of connected devices should not exceed 200W.
7. Spécifications
| Fonctionnalité | Détail |
|---|---|
| Modèle | BE350G |
| Capacité | 350 200 VA / XNUMX W |
| Dimensions du produit (H x L x P) | 6.25 x 3.5 x 11 pouces |
| Poids de l'article | 8 livres |
| Vol d'entréetage | 120 volts |
| Type de batterie | Acide de plomb |
| Nombre total de prises | 6 (3 batteries de secours + protection contre les surtensions, 3 protections uniquement contre les surtensions) |
| Fabricant | APC |
| Date de première disponibilité | 9 mai 2008 |
8. Garantie et assistance
For detailed warranty information, technical support, or to purchase replacement parts, please visit the official APC website or contact APC customer service directly. It is recommended to keep your purchase receipt as proof of purchase for warranty claims.
APC Customer Support: Refer to the contact information provided on the official APC website ou dans l'emballage de votre produit.