Introduction
This manual provides instructions for the installation, operation, and maintenance of the Intermatic T174 DPST 24 Hour Time Switch. This electromechanical timer is designed for controlling electrical loads over a 24-hour period.
Image: Intermatic T174 DPST 24 Hour Time Switch. This image shows the front view of the timer with its gray metal enclosure and the dial for setting time.
Consignes de sécurité
WARNING: Risk of electric shock. Installation and servicing must be performed by qualified personnel only. Disconnect power at the circuit breaker or fuse box before installing or servicing the timer.
- Respectez toujours les codes et réglementations électriques locaux.
- Assurez-vous que l'alimentation électrique corresponde au volume du minuteurtage rating (208-277V AC).
- Do not exceed the maximum current and horsepower ratings of the timer.
- This device is intended for indoor use in a Type 1 enclosure.
Contenu du colis
The Intermatic T174 Time Switch package typically includes:
- One (1) Intermatic T174 Time Switch Unit
- Guide d'instructions
- Two (2) Trippers for setting ON/OFF times
Configuration et installation
The Intermatic T174 is designed for fixed installation. Proper wiring is crucial for safe and correct operation.
Montage
- Choisissez un emplacement intérieur approprié pour installer la minuterie, en veillant à ce qu'elle soit protégée de l'humidité et des températures extrêmes.
- Securely mount the timer's enclosure to a wall or suitable surface using appropriate fasteners.
Wiring (DPST Configuration)
The T174 features a Double Pole, Single Throw (DPST) contact form, meaning it controls two independent circuits or a single 2-pole circuit simultaneously.
- DISCONNECT ALL POWER to the circuit at the main service panel before proceeding.
- Open the timer's enclosure.
- Connect the incoming power lines (L1 and L2 for 208-277V AC) to the designated "LINE" terminals on the timer.
- Connect the load wires (to the device being controlled) to the designated "LOAD" terminals. Ensure correct polarity if applicable.
- Assurez-vous que toutes les connexions des fils sont bien serrées et sécurisées.
- Close the timer's enclosure securely.
- Rétablissez l'alimentation du circuit.
Consultez un électricien qualifié si vous avez des doutes concernant les procédures de câblage.
Mode d'emploi
The T174 uses a mechanical dial and trippers to set the ON/OFF schedule.
Réglage de l'heure actuelle
- Rotate the timer dial clockwise until the current time aligns with the "TIME SET" arrow or indicator on the timer mechanism.
- Ensure AM/PM is correctly observed if the dial has such markings.
Réglage des heures de marche/arrêt
The timer comes with two trippers: one "ON" tripper and one "OFF" tripper. Additional trippers can be purchased separately (Extra Trippers 11Z965).
- Locate the "ON" tripper (typically silver or light-colored) and the "OFF" tripper (typically black or dark-colored).
- Snap the "ON" tripper onto the dial at the desired time you want the connected device to turn ON.
- Snap the "OFF" tripper onto the dial at the desired time you want the connected device to turn OFF.
- You can set up to 12 ON/OFF cycles per 24-hour period using additional trippers. The minimum time setting is 1 hour.
Commande manuelle
The T174 typically includes a manual override switch or lever. This allows you to temporarily turn the connected device ON or OFF without affecting the programmed schedule. Refer to the specific markings on your timer for the manual override function.
Day Skipper Function
The timer features a Day Skipper function, allowing you to prevent operation on specific days of the week. Consult the detailed instruction guide included with your unit for specific setup of this feature.
Entretien
The Intermatic T174 Time Switch is designed for reliable, long-term operation with minimal maintenance.
- Inspectez régulièrement la minuterie pour détecter tout signe de dommage ou de connexion desserrée.
- Keep the enclosure clean and free from dust and debris.
- Ne tentez pas de lubrifier les composants internes.
Dépannage
| Problème | Cause possible | Solution |
|---|---|---|
| La minuterie ne fonctionne pas. | Le minuteur n'est pas alimenté. | Check circuit breaker or fuse. Ensure wiring connections are secure. |
| Connected device does not turn ON/OFF at programmed times. | Incorrect tripper placement or current time setting. | Verify tripper positions and ensure the current time is accurately set on the dial. Check manual override switch position. |
| Timer motor is noisy. | Fonctionnement normal de certaines minuteries mécaniques. | If noise is excessive or new, contact support. |
| Timer operates but device does not. | Faulty wiring to the load or issue with the connected device. | Verify load wiring. Test the connected device directly to ensure it is functional. |
Caractéristiques
| Fonctionnalité | Détail |
|---|---|
| Numéro de modèle | T174 |
| Taper | Minuterie électromécanique |
| Opération | 24 heures |
| Nombre de pôles | 2 |
| Formulaire de contact | DPST-NO (Double Pole, Single Throw - Normally Open) |
| Voltage | 208-277V AC |
| Amprage | 40 A |
| Contact HP @ 120V | 2 CV |
| Contact HP @ 240V | 5 CV |
| Day Skipper | Oui |
| Type de boîtier | Steel, Type 1 Indoor Enclosure |
| Finition | Émail gris |
| Réglage du temps minimum | 1 heure |
| Réglage de la durée maximale | 23 heures |
| Maximum ON/OFF Cycles | 12 |
| Dimensions (H x L x P) | 7 13/16 in x 5 in x 3 in (Approximate) |
| Poids de l'article | 2.75 - 2.8 livres |
| Included Trippers | 2 |
| Code UPC | 078275174214 |
| Fabricant | Intermatic Incorporé |
Garantie et assistance
The Intermatic T174 Time Switch comes with a manufacturer's warranty. For specific warranty details, please refer to the documentation included with your product or visit the official Intermatic website.
For technical support, troubleshooting assistance, or to inquire about replacement parts, please contact Intermatic customer service. You can often find support information and additional resources on the Boutique Intermatic sur Amazon ou leur entreprise officielle website.