APCAP7921

APC AP7921 Switched Rack PDU User Manual

Modèle: AP7921

1. Introduction et plusview

The APC AP7921 is a Switched Rack Power Distribution Unit (PDU) designed for efficient power management in rack environments. This 1U horizontal mounting PDU provides eight (8) C13 output receptacles and accepts a 208V-230V input via an IEC-320 C20 connector, supporting a 16A single-phase load. It offers advanced features such as remote individual outlet control, local current monitoring, and remote management capabilities, making it suitable for critical IT infrastructure.

APC AP7921 Switched Rack PDU front view with 8 C13 outlets and display

Figure 1.1 : Face avant view of the APC AP7921 Switched Rack PDU, showing the eight C13 output receptacles and the local current monitoring display.

Caractéristiques principales :

2. Consignes de sécurité

Read and understand all instructions before installing or operating this equipment. Failure to follow these instructions may result in electric shock, fire, or serious injury.

3. Contenu du colis

Verify that all components are present upon unpacking. If any items are missing or damaged, contact your vendor or APC support.

4. Configuration et installation

4.1 Montage en rack

  1. Identify a 1U (1.75 inches) space in your standard 19-inch server rack.
  2. Attach the provided mounting brackets to the sides of the PDU using the included screws.
  3. Secure the PDU into the rack using appropriate rack screws, ensuring it is firmly seated.

4.2 Connexion d'alimentation

  1. Connect the IEC-320 C20 input connector of the PDU to a compatible 208V-230V, 16A power source. Ensure the power source is properly grounded and capable of supplying the required current.
  2. Connect your IT equipment's power cords to the eight (8) C13 output receptacles on the PDU. Distribute the load evenly across the outlets if possible.

5. Fonctionnement

5.1 Mise sous tension

Once the PDU is connected to a power source, it will power on automatically. The local current monitoring display will illuminate, showing the total current draw.

5.2 Local Current Monitoring

The integrated display on the front panel provides real-time information on the total current being drawn by all connected devices. This helps in preventing overloads and managing power capacity.

5.3 Remote Individual Outlet Control

The AP7921 allows for remote control of each individual C13 outlet. This feature enables users to power cycle, turn on, or turn off connected equipment remotely, which is beneficial for troubleshooting or managing power to specific devices without physical access.

5.4 Power Delays

The PDU supports configurable power-on and power-off delays for its outlets. This feature helps in sequencing the startup of equipment to prevent inrush current overloads and manage system dependencies.

6. Configuration

The AP7921 PDU offers various configuration options through its network interface for remote management.

6.1 Accès réseau

Connect the PDU to your network using an Ethernet cable. Access the PDU's web interface via its assigned IP address to configure settings, monitor status, and control outlets. Refer to the network configuration guide for initial setup.

6.2 Seuil d'alarme

Configure alarm thresholds for current draw. The PDU can send alerts via email or SNMP traps if the current exceeds or falls below specified limits, helping to prevent overloads or identify power issues.

6.3 mises à jour du micrologiciel

The PDU's firmware is flash upgradeable. Regularly check the APC website for the latest firmware versions to ensure optimal performance and access to new features. Follow the provided instructions for firmware upgrade procedures.

7. Entretien

7.1 Nettoyage

Periodically clean the exterior of the PDU with a soft, dry cloth. Do not use liquid cleaners or solvents. Ensure the PDU is disconnected from the power source before cleaning.

7.2 Considérations environnementales

Ensure the PDU operates within its specified temperature and humidity ranges. Maintain proper airflow around the unit to prevent overheating.

8. Dépannage

8.1 Absence d'alimentation aux prises

8.2 Overload Indication

8.3 Problèmes d'accès à distance

9. Spécifications

FonctionnalitéSpécification
Numéro de modèleAP7921
Vol d'entréetage208V-230V
Courant d'entrée16A
Connecteur d'entréeCEI-320 C20
Prises de sortie8 x IEC-320 C13
Facteur de forme1U Horizontal Rack-Mountable
Dimensions du produit (H x L x P)2.7 x 18.5 x 13.5 pouces (environ)
Poids de l'article1.54 livres
Longueur du cordon7.8 pouces
Dossier spécialMountable, Switched Outlets, Remote Management
FabricantAPC

10. Garantie et assistance

For warranty information, technical support, or service inquiries, please refer to the official APC website or contact your local APC representative. Ensure you have your product model number (AP7921) and serial number available when contacting support.

Ressources en ligne : Visite www.apc.com for product documentation, software downloads, and support contact information.

Documents connexes - AP7921

Préview Guide d'installation de l'unité de distribution d'alimentation commutée APC pour rack
Guide d'installation et d'utilisation des unités de distribution d'alimentation (PDU) APC Switched Rack, couvrant les fonctionnalités, l'installation, la configuration, l'accès, la garantie et l'assistance.
Préview APC Easy PDU Metered-by-Outlet Rack Power Distribution Unit Installation Guide
Installation guide for APC Easy PDU Metered-by-Outlet Rack Power Distribution Units (EPDU2116MBO, EPDU2132MBO, EPDU2216MBO, EPDU2232MBO), covering safety, installation, display interface, and specifications.
Préview Guide d'installation du remplacement des PDU APC SMT2200/SMT3000 | Schneider Electric
Ce guide fournit les instructions d'installation d'un panneau PDU de remplacement optionnel pour les systèmes UPS APC SMT2200 et SMT3000. Il comprend des consignes de sécurité importantes, des instructions de manipulation du produit et une procédure d'installation détaillée.
Préview Guide produit APC NetShelter Rack PDU Advanced et systèmes de rack
Guide complet des PDU rack APC NetShelter, incluant les modèles avancés à 4 prises en 1, ainsi que les options de base, mesurées, commutées et mesurées par prise pour la gestion de l'alimentation des centres de données. Caractéristiques techniques, accessoires et solutions pour systèmes rack.
Préview Guide d'installation de l'unité de distribution d'alimentation en rack APC
Instructions d'installation des unités de distribution d'alimentation (PDU) pour racks APC, y compris les précautions de sécurité, les procédures de montage et les informations sur l'interface d'affichage.
Préview Manuel d'installation et d'utilisation des abris APC NetShelter AR1000, AR1001 et AR1100
Ce manuel fournit des instructions détaillées pour l'installation, la configuration et la maintenance des baies de brassage NetShelter d'American Power Conversion (APC), notamment les modèles AR1000, AR1001 et AR1100. Il couvre l'inventaire des produits, les avertissements, la configuration, le nivellement, la stabilisation et les informations relatives à la garantie.