Introduction
This manual provides essential instructions for the safe and effective use of your BBLOVE Digital Thermometer, Model AET-F372. Please read this manual thoroughly before using the device and keep it for future reference. This thermometer is designed for accurate temperature measurement in adults and children.
Consignes de sécurité
- Do not immerse the entire thermometer in water for extended periods. The device is IP65 water-resistant for cleaning, but not for full submersion.
- Tenir hors de portée des enfants. Petites pièces pouvant présenter un risque d'étouffement.
- Do not bite the thermometer probe.
- Avoid dropping or subjecting the thermometer to strong impacts.
- N’essayez pas de démonter ou de réparer l’appareil vous-même. Contactez le service client si une intervention est nécessaire.
- Rangez le thermomètre dans un endroit frais et sec, à l'abri de la lumière directe du soleil et des températures extrêmes.
- Consult a physician if you have concerns about your temperature readings or health.
Composants du produit
The BBLOVE Digital Thermometer package includes:
- BBLOVE Digital Thermometer (Model AET-F372)
- Cas de charge magnétique
- Manuel de l'utilisateur (ce document)

Figure 1 : BBLOVE Digital Thermometer with its magnetic charging case.

Figure 2 : The thermometer securely stored within its magnetic charging case.
Installation
1. Charge initiale
Before first use, ensure the thermometer is fully charged. Place the thermometer into its magnetic charging case. The case will provide power to the thermometer. A full charge typically takes a few hours. The LED display on the thermometer will indicate charging status.
2. Mise sous/hors tension
The thermometer powers on automatically when removed from the charging case. To power off, place it back into the charging case. The device also features an automatic shutdown function after a period of inactivity to conserve battery.
Mode d'emploi
1. Préparation de la mesure
- Ensure the thermometer probe is clean and disinfected before each use. Refer to the "Maintenance" section for cleaning instructions.
- Remove the thermometer from its charging case. It will automatically power on and display the last measured temperature.
- To reset the temperature data for a new measurement, gently shake the thermometer or place it back into the charging case briefly and then remove it again.
2. Prise de température
The BBLOVE Digital Thermometer is suitable for oral, rectal, and axillary (underarm) temperature measurements. For the most accurate results, it is recommended to continue measuring for 3-5 minutes.
- Utilisation orale: Place the probe tip under the tongue, as close to the heat pocket as possible. Close your mouth and hold the thermometer in place.
- Usage rectal: Apply a water-soluble lubricant to the probe tip. Gently insert the tip no more than 1/2 inch into the rectum. This method is generally recommended for infants and young children for accuracy.
- Utilisation axillaire (aisselle) : Place the probe tip in the armpit, ensuring good skin contact. Hold the arm firmly against the body. This method is less accurate than oral or rectal measurements.
The thermometer will provide a fast reading. For medical-grade accuracy, continue holding the thermometer in place for 3-5 minutes until the reading stabilizes. A vibration alert will signal when a stable reading is achieved.

Figure 3 : Gros plan view of the BBLOVE Digital Thermometer, showing the probe and display area.
3. Lecture de l'affichage
The large LED display shows the temperature reading.
- "Lo" is displayed when the measured temperature is below 89.6°F (32°C).
- "Hi" is displayed when the measured temperature is above 109.4°F (43°C).
4. Fonction de mémoire
Upon powering on, the thermometer automatically displays the last measured temperature. This allows for easy tracking of temperature changes over time.
Entretien
1. Nettoyage et désinfection
The thermometer is designed with an IP65 water discharge level, making it easy to clean.
- After each use, clean the probe tip with soap and warm water or wipe it with an alcohol swab (70% isopropyl alcohol).
- You can rinse the probe directly under a faucet.
- Important: Do not immerse the entire thermometer in water for a long time. Only the probe area is designed for direct rinsing.
- Laisser le thermomètre sécher complètement à l'air libre avant de le ranger.
2. Stockage
Store the thermometer in its magnetic charging case when not in use. This protects the device and keeps it charged. Store in a dry place, away from extreme temperatures and direct sunlight.
Dépannage
| Problème | Cause possible | Solution |
|---|---|---|
| Le thermomètre ne s'allume pas. | Low battery or not properly removed from case. | Place in charging case to charge. Ensure it is fully removed from the case. |
| Lectures inexactes. | Improper placement, insufficient measurement time, or probe not clean. | Ensure proper placement (oral/rectal recommended). Measure for 3-5 minutes. Clean the probe thoroughly. Do not touch the probe with hands during measurement. |
| Affichage de « Lo » ou « Hi ». | Temperature outside measurement range. | "Lo" indicates below 89.6°F (32°C). "Hi" indicates above 109.4°F (43°C). This is normal if the ambient temperature is outside the human body range. If measuring body temperature, re-evaluate placement. |
| Thermometer does not reset. | Not properly reset. | Gently shake the thermometer or place it back into the charging case briefly and then remove it again to reset for a new measurement. |
Caractéristiques
- Modèle: AET-F372
- Marque: BLOVE
- Plage de mesure : 89.6°F - 109.4°F (32°C - 43°C)
- Précision: Medical-grade
- Afficher: DIRIGÉ
- Résistance à l'eau : IP65
- Poids: Approximately 5 grams (thermometer only)
- Conditions de fonctionnement : 5°C-40°C, 15%RH-80%RH, 70kPa-106kPa
- Conditions de stockage : -20°C-55°C, 15%RH-93%RH, 70kPa-106kPa
- Fabricant: Alicn Medical Shenzhen Inc
Garantie et assistance
BBLOVE products are manufactured with high-quality standards. For warranty information, technical support, or service inquiries, please refer to the warranty card included with your purchase or visit the official BBLOVE webVeuillez conserver votre preuve d'achat pour toute réclamation au titre de la garantie.
For further assistance, you may contact the manufacturer:
- Fabricant: Alicn Medical Shenzhen Inc
- Adresse: Room 4C, Building 1, Zhongzheng Biomedical Industrial Park, No. 21 Linhui Road, Jinsha Community, Kengzi Street, Pingshan District, 518122 Shenzhen, Guangdong, PEOPLE'S REPUBLIC OF CHINA
- Tél.: 0086-755-28301548
- E-mail: info@alicn-med.com
- Website: http://www.alicn-med.com