1. Introduction
This manual provides essential information for the safe and effective use of the replacement battery for the Stryker 6506 Power-PRO XT Cot. This NiCd battery, model 6500-033-000 B11893, is designed to provide reliable power for emergency medical services equipment. Please read this manual thoroughly before installation and operation to ensure proper function and longevity of the battery.
The battery pack features a ventless, sealed construction, making it suitable for demanding environments. Its design allows for quick and easy replacement within an ambulance vehicle.
2. Consignes de sécurité
Always observe the following safety precautions when handling, installing, or charging the battery:
- Ne pas disassemble, crush, puncture, or short-circuit the battery.
- Ne pas expose the battery to extreme temperatures (above 60°C / 140°F or below -20°C / -4°F) or direct sunlight.
- Ne pas immerse the battery in water or other liquids.
- Use only approved charging methods and equipment.
- Gardez la batterie hors de portée des enfants et des animaux domestiques.
- If the battery shows signs of damage, leakage, or overheating, discontinue use immediately and dispose of it properly according to local regulations.
- Assurez une ventilation adéquate pendant la charge.
3. Contenu du colis
Vérifiez que tous les articles sont présents lors du déballage :
- 1 x Stryker 6506 Power-PRO XT Cot Replacement Battery (Model 6500-033-000 B11893)
4. Configuration et installation
The battery pack is designed for quick and easy replacement in the Stryker 6506 Power-PRO XT Cot.
4.1 Installation de la batterie
- Ensure the Stryker cot is powered off and disconnected from any external power sources before attempting battery replacement.
- Locate the existing battery compartment on the Stryker 6506 Power-PRO XT Cot.
- To remove the old battery pack, press the release mechanism (if present) and slide the old pack off. The design allows for a simple "click and slide off" action.
- Align the new replacement battery pack (Model 6500-033-000 B11893) with the battery slot.
- Slide the new battery pack into place until it clicks securely. Ensure it is fully seated and locked.
- Power on the cot and verify that the battery is recognized and functioning correctly.

Image showing the compact design of the replacement battery pack, ready for installation.
5. Fonctionnement
5.1 Chargement de la batterie
The battery pack can be recharged using a wall outlet or directly within an ambulance vehicle's charging system. The charging process is designed to be user-friendly, requiring no complex protocols.
- Temps de charge : A fully depleted battery pack can be fully charged in approximately two (2) hours.
- Indicateurs de charge : Refer to your Stryker 6506 Power-PRO XT Cot's display or charging station indicators for charging status.
5.2 Performances de la batterie
A fully charged battery pack is capable of powering 15 to 20 "calls" with patients weighing an average of 250 lbs. Actual performance may vary based on usage patterns, cot model, patient weight, and environmental conditions.
6. Entretien
Un entretien approprié garantit la longévité et les performances optimales de votre batterie.
- Chargement régulier : Keep the battery charged. Avoid leaving the battery in a fully discharged state for extended periods.
- Nettoyage: Wipe the battery pack with a dry, clean cloth. Do not use harsh chemicals or abrasive cleaners. Ensure connectors are free of dirt and debris.
- Stockage: If storing the battery for an extended period, ensure it is partially charged (around 50%) and stored in a cool, dry place away from direct sunlight and extreme temperatures. Recharge every 3-6 months to prevent deep discharge.
- Inspection: Periodically inspect the battery for any signs of physical damage, swelling, or leakage. Replace immediately if any issues are observed.
7. Dépannage
Si vous rencontrez des problèmes avec votre batterie, consultez les problèmes et solutions courants suivants :
| Problème | Cause possible | Solution |
|---|---|---|
| La batterie ne charge pas |
|
|
| Temps de fonctionnement court |
|
|
| Battery overheating during charge/use |
|
|
Si le problème persiste après avoir essayé ces solutions, veuillez contacter le service client.
8. Spécifications
| Numéro de modèle | 6500-033-000 B11893 |
| Type de batterie | NiCd (Nickel-Cadmium) |
| Vol nominaltage | 24.0V |
| Capacité nominale | 2.5 Ah |
| Construction | Ventless, Sealed |
| Temps de charge approximatif | 2 hours (from fully discharged) |
| Fabricant | Unipower (Generic Brand) |
| Compatibilité | Stryker 6506 Power-PRO XT Cot |
9. Garantie et assistance
Pour toute information concernant la garantie et l'assistance client, veuillez consulter la documentation fournie avec votre achat ou contacter directement le vendeur. Conservez votre preuve d'achat pour toute réclamation au titre de la garantie.
For technical assistance or questions regarding the Stryker 6506 Power-PRO XT Cot, please consult the cot's official user manual or contact Stryker customer service.