Introduction
Welcome to the ULTRICS Digital Multimeter D2 user manual. This device is designed for precise and reliable electrical measurements, suitable for professionals and DIY enthusiasts. It accurately measures AC/DC voltage, DC current, resistance, continuity, and diodes. This manual provides essential information for safe and effective operation, helping you to maximize the utility of your new multimeter.
Consignes de sécurité
AVERTISSEMENT: Always exercise extreme caution when working with electrical circuits. Improper use of this multimeter can result in electric shock, personal injury, or damage to the device.
- Ne dépassez pas les valeurs d'entrée maximales pour chaque plage.
- Do not use the multimeter if it or the test leads appear damaged. Inspect them before each use.
- Ensure the function switch is in the correct position before making measurements. Changing ranges while connected to a live circuit can cause damage.
- Disconnect power to the circuit before measuring resistance, continuity, or diodes.
- Soyez prudent lorsque vous travaillez avec des volumestages au-dessus de 30 V CA RMS, 42 V crête ou 60 V CC. Ces voltages pose a significant shock hazard.
- Always connect the common (COM) test lead first, then the live lead. Disconnect the live lead first, then the common lead.
- Replace the battery when the low battery indicator appears to ensure accurate readings and proper device function.
This multimeter is rated CAT II 600V, indicating its suitability for measurements on circuits directly connected to the low-voltagl'installation.
Contenu du colis
Vérifiez que tous les éléments sont présents dans le colis :
- 1 x ULTRICS Digital Multimeter D2
- 2 cordons de test (rouge et noir)
- Batterie 1 x 9V
- 1 x Manuel d'utilisation (ce document)

Image: Contents of the ULTRICS Digital Multimeter D2 package, including the multimeter, red and black test leads, and a 9V battery.
Produit terminéview
Familiarize yourself with the components of your ULTRICS Digital Multimeter D2.

Image: Detailed diagram of the ULTRICS Digital Multimeter D2, highlighting its key components such as the LCD display, data hold button, backlight button, function switch, test lead jacks, and protective rubber shell.
- Écran LCD : Shows measurement readings, units, and polarity. Features a bright backlight for low-light conditions.
- Bouton de maintien des données : Freezes the current reading on the display for easier recording.
- Bouton de rétroéclairage : Active ou désactive le rétroéclairage de l'écran.
- Function Switch (Rotary Dial): Sélectionne la fonction et la plage de mesure souhaitées.
- Prise d'entrée 10A : Used for measuring DC current up to 10 Ampc'est.
- COM (Common) Input Jack: The negative (-) input for all measurements. Always connect the black test lead here.
- Prise d'entrée VΩmA : The positive (+) input for voltage, résistance et milliampere current measurements. Connect the red test lead here.
- Transistor Test Jacks (hFE): Used for testing NPN and PNP transistors.
- Coque de protection en caoutchouc : Provides durability and protection against minor impacts and splashes.
- Béquille pliable : Permet une utilisation mains libres et facile viewangle de vue.
Installation
Installation de la batterie
The ULTRICS Digital Multimeter D2 requires one 9V battery (included).
- Localisez le compartiment à piles à l'arrière du multimètre.
- Utilisez un tournevis pour retirer la vis qui fixe le couvercle de la batterie.
- Retirez délicatement le couvercle de la batterie.
- Connect the 9V battery to the battery clips, ensuring correct polarity (+ to + and - to -).
- Placez la pile dans le compartiment.
- Replacez le couvercle de la batterie et fixez-le avec la vis.
Connexion des cordons de test
Assurez-vous toujours que les cordons de test sont correctement connectés avant d'effectuer des mesures.
- Insert the black test lead's banana plug into the COM Prise d'entrée (commune).
- Pour la plupart des mesures (voltage, resistance, continuity, diode, small current), insert the red test lead's banana plug into the VΩmA prise d'entrée.
- For high current measurements (up to 10A DC), insert the red test lead's banana plug into the 10A prise d'entrée.
Mode d'emploi
This section details how to perform various measurements using your multimeter.

Image: Visual representation of the multimeter's versatile functions, including AC/DC Voltage, AC/DC Current, Diode, Continuity, Ampere, Capacity, Battery Test, Resistance, and Transistor measurements.
Mesure du vol continutage (VCC)
- Connectez le cordon de test noir au COM Jack et le test rouge mènent à VΩmA jack.
- Turn the function switch to the desired VDC range (e.g., 200mV, 2V, 20V, 200V, 600V). If unsure, start with the highest range and decrease as needed.
- Connectez les cordons de test en parallèle aux bornes du composant ou du circuit à mesurer.
- Lire le voltage valeur sur l'écran LCD.
Mesurer le vol CAtage (VAC)
- Connectez le cordon de test noir au COM Jack et le test rouge mènent à VΩmA jack.
- Turn the function switch to the desired VAC range (e.g., 200V, 600V).
- Connectez les cordons de test en parallèle aux bornes du potentiel alternatif.tagla source.
- Lire le voltage valeur sur l'écran LCD.
Measuring DC Current (ADC)
PRUDENCE: Never connect the multimeter in parallel when measuring current. Always connect it in series with the circuit. Improper connection can damage the multimeter or the circuit.
- Coupez l’alimentation du circuit.
- Pour les courants jusqu'à 200 mA, connectez le fil de test noir à la COM Jack et le test rouge mènent à VΩmA jack.
- Pour les courants jusqu'à 10 A, connectez le fil de test noir à la COM Jack et le test rouge mènent à 10A jack.
- Turn the function switch to the desired ADC range (e.g., 200µA, 2mA, 20mA, 200mA, 10A).
- Coupez le circuit et branchez le multimètre en série avec celui-ci.
- Turn on power to the circuit.
- Lire la valeur actuelle sur l'écran LCD.
- Turn off power to the circuit before disconnecting the multimeter.
Mesure de la résistance (Ω)
PRUDENCE: Ensure the circuit is completely de-energized before measuring resistance. Measuring resistance on a live circuit can damage the multimeter.
- Connectez le cordon de test noir au COM Jack et le test rouge mènent à VΩmA jack.
- Turn the function switch to the desired Ω range (e.g., 200Ω, 2kΩ, 20kΩ, 200kΩ, 2MΩ, 20MΩ).
- Connectez les cordons de test aux bornes du composant dont vous souhaitez mesurer la résistance.
- Lisez la valeur de résistance sur l'écran LCD.
Test de continuité
The continuity test checks for a complete circuit path. An audible buzzer will sound if continuity is detected.
- Connectez le cordon de test noir au COM Jack et le test rouge mènent à VΩmA jack.
- Tournez le commutateur de fonction sur la Continuité (buzzer) position.
- Connectez les cordons de test aux bornes du circuit ou du composant.
- Si la résistance est inférieure à environ 50 Ω, le buzzer retentira, indiquant la continuité.
Test de diode
Le test de diode mesure le vol directtagla goutte d'une diode.
- Connectez le cordon de test noir au COM Jack et le test rouge mènent à VΩmA jack.
- Tournez le commutateur de fonction sur la Diode position.
- Connect the red test lead to the anode (+) and the black test lead to the cathode (-) of the diode.
- Lire le vol avanttage drop on the LCD display. Reverse the leads; the display should show "OL" (Overload) for a good diode.
Test de transistor hFE
This function tests the DC current gain (hFE) of NPN and PNP transistors.
- Tournez le commutateur de fonction sur la hFE position.
- Identify the Emitter (E), Base (B), and Collector (C) leads of the transistor.
- Insert the transistor leads into the corresponding holes in the hFE socket on the multimeter, ensuring correct NPN or PNP type.
- Read the hFE value on the LCD display.
Fonction de maintien des données
Appuyez sur le PRISE Appuyez sur ce bouton pour figer la lecture en cours. Appuyez de nouveau pour relâcher le blocage et reprendre la lecture en temps réel.
Fonction de rétroéclairage
Appuyez sur le Rétroéclairage button to turn the LCD backlight on or off, improving visibility in dim environments.

Image : Un gros plan view of the multimeter's LCD display, demonstrating its bright backlight feature for enhanced readability in various lighting conditions.
Entretien
Nettoyage
Pour nettoyer le multimètre, essuyez le boîtier avec un chiffon humide.amp cloth and a mild detergent. Do not use abrasives or solvents, as these may damage the casing ou affichage.
Remplacement de la batterie
When the low battery indicator appears on the display, replace the 9V battery as described in the "Installing the Battery" section to ensure continued accurate readings.
Remplacement du fusible
If the current measurement function stops working, the fuse may need replacement. This multimeter is equipped with internal fuses for protection.
- Assurez-vous que le multimètre est éteint et que tous les cordons de test sont déconnectés.
- Retirez le couvercle de la batterie et la batterie.
- Carefully open the main casing (this may require removing additional screws, typically located under the rubber shell).
- Locate the fuse(s) on the circuit board. This model typically uses a 200mA/250V fuse for the mA range and a 10A/250V fuse for the 10A range.
- Replace the blown fuse with a fuse of the same type and rating. Never use a fuse with a different rating.
- Reassemble the multimeter, ensuring all screws are tightened and the casing is properly sealed.
Stockage
If the multimeter is not used for a long period, remove the battery to prevent leakage and store the device in a cool, dry place, away from direct sunlight and extreme temperatures.
Dépannage
| Problème | Cause possible | Solution |
|---|---|---|
| Aucun affichage ou affichage faible | Batterie morte ou faible | Remplacez la pile 9V. |
| « OL » (Surcharge) affiché | Input value exceeds selected range; open circuit (for resistance/continuity) | Select a higher range; check for breaks in the circuit or component. |
| Lectures incorrectes | Fonction/plage sélectionnée incorrecte ; mauvaise connexion des câbles de test ; batterie faible | Verify function switch position and range; ensure leads are firmly connected; replace battery. |
| La mesure du courant ne fonctionne pas. | Fusible grillé | Remplacez le fusible approprié (reportez-vous à la section Maintenance). |
| Pas de buzzer de continuité | Open circuit; resistance too high | Ensure circuit is closed; check resistance value (buzzer typically activates below 50Ω). |
Caractéristiques
| Fonctionnalité | Détail |
|---|---|
| Modèle | Digital Multimeter D2 |
| Afficher | 3 ½ digit LCD, 1999 counts, with backlight |
| Vol CCtage | 200 mV / 2 V / 20 V / 200 V / 600 V |
| Vol ACtage | 200 V / 600 V |
| Courant continu | 200µA / 2mA / 20mA / 200mA / 10A |
| Résistance | 200Ω / 2kΩ / 20kΩ / 200kΩ / 2MΩ / 20MΩ |
| Test de diode | Oui |
| Buzzer de continuité | Oui |
| Test de transistor hFE | Oui |
| Conservation des données | Oui |
| Source d'énergie | Batterie 9V |
| Cote de sécurité | IEC CAT II 600V, CE, RoHS compliant |
| Dimensions (L x l x H) | 14.6 x 10 x 5 cm (5.75 x 3.94 x 1.97 pouces) |
| Poids | 240 grammes (0.53 livres) |
Garantie et assistance
ULTRICS provides a 12-month warranty for this product, covering manufacturing defects from the date of purchase. Please retain your proof of purchase for warranty claims.
For technical support, warranty claims, or any questions regarding your ULTRICS Digital Multimeter D2, please contact ULTRICS customer service through the retailer's platform or the official ULTRICS webVeuillez vous munir de vos informations d'achat et du numéro de modèle lorsque vous contactez l'assistance.
Fabricant: ULTRICES
Numéro de modèle : Digital Multimeter D2
ASIN: B0DYP62MW7