ZOYI ZT-MD1

ZOYI ZT-MD1 Mini Digital LCR Meter Tweezer User Manual

Model: ZT-MD1

1. Introduction

The ZOYI ZT-MD1 is a compact, high-precision digital LCR meter designed in a tweezer form factor. It features a 1.14-inch color OLED screen and is powered by a lithium polymer battery, offering extended operation. This device intelligently identifies and accurately measures resistance, capacitance, and inductance across a wide range with high precision. Its flexible measuring arms and detachable gold-plated tips ensure reliable contact for various SMD or other LCR parameter measurements. This manual provides essential information for the safe and effective use of your ZT-MD1 LCR Meter Tweezer.

2. Contenu du colis

Vérifiez que tous les éléments énumérés ci-dessous sont présents dans votre colis :

  • 1x ZOYI ZT-MD1 LCR Meter Tweezer
  • 1 Pair x Replaceable Tweezer Tips (Gold-plated)
  • 1 câble de données USB Type-C
  • 1 x Manuel d'utilisation (ce document)
  • 1 x sac de rangement
ZOYI ZT-MD1 LCR Meter Tweezer and accessories

Image: Contents of the ZOYI ZT-MD1 package, including the LCR meter, USB cable, extra tweezer tips, and storage bag.

3. Produit terminéview

The ZOYI ZT-MD1 is designed for precise measurement of electronic components. Key features include:

  • Écran OLED couleur de 1.14 pouce : Provides a clear, high-definition display for measurement results.
  • Reconnaissance automatique : Intelligently identifies and measures resistance, capacitance, and inductance.
  • Large plage de mesure :
    • Resistance (R): 1mΩ - 10MΩ
    • Capacitance (C): 1pF - 20mF
    • Inductance (L): 1µH - 60H
  • Test de diodes : Measures on-voltage (approximately 0.7V).
  • Frequency Test: Selectable frequencies of 100Hz, 1kHz, 10KHz.
  • Level Test: Vol d'essaitages of 0.3V, 0.6V RMS.
  • Flexible Tweezer Arms: Equipped with detachable gold-plated tips for reliable contact.
  • Étalonnage utilisateur : Allows calibration based on standard resistors.
  • Maintien de données: Fige la mesure actuelle affichée.
  • Historique : Connect to a PC to view and export measurement history.
  • Extinction automatique: Préserve l'autonomie de la batterie.
  • Flippable Screen: Pour plus de commodité viewdans différentes orientations.
ZOYI ZT-MD1 LCR Meter Tweezer displaying measurement features

Image: The ZOYI ZT-MD1 LCR Meter Tweezer highlighting its key features and measurement capabilities, including resistance, diode, inductance, frequency, and capacitance ranges.

ZOYI ZT-MD1 LCR Meter Tweezer with LCD color screen

Image : Gros plan view of the ZOYI ZT-MD1's 1.14-inch color OLED screen, demonstrating its clear, high-definition display.

ZOYI ZT-MD1 LCR Meter Tweezer displaying main and secondary parameters

Image: The ZOYI ZT-MD1 displaying both main (L/C/R) and secondary (D/Q) measurement parameters simultaneously on its screen.

ZOYI ZT-MD1 LCR Meter Tweezer with flippable screen feature

Image: The ZOYI ZT-MD1 demonstrating its flippable screen feature, allowing for convenient measurement viewsous différents angles.

4. Installation

4.1. Charge initiale

Before first use, fully charge the device. Connect the provided USB Type-C cable to the charging port on the ZT-MD1 and the other end to a 5V/A USB power adapter (not included). The battery indicator on the screen will show charging status. A full charge ensures optimal performance and battery life.

4.2. Attaching Tweezer Tips

The ZT-MD1 comes with detachable gold-plated tweezer tips. Ensure they are securely attached to the arms of the device for accurate measurements. Gently push the tips into place until they are firm. To replace, carefully pull them out.

ZOYI ZT-MD1 LCR Meter Tweezer dimensions

Image: The ZOYI ZT-MD1 LCR Meter Tweezer with its dimensions (146mm length, 30mm width) indicated, showing its compact size.

5. Mode d'emploi

5.1. Marche/Arrêt

Press and hold the power button to turn the device on or off. The OLED screen will illuminate upon power-on.

5.2. Automatic Measurement

The ZT-MD1 defaults to automatic recognition mode. Simply touch the tweezer tips to the component you wish to measure. The device will automatically detect whether it is a resistor, capacitor, or inductor and display the corresponding value along with secondary parameters (D, Q, Rs) if applicable.

5.3. Manual Mode and Parameter Selection

Refer to the on-screen interface for options to switch between automatic and manual measurement modes, or to select specific test frequencies (100Hz, 1kHz, 10KHz) and test voltages (0.3V, 0.6V RMS) if needed for advanced measurements.

5.4. Fonction de conservation des données

Press the "Hold" button (if available, or indicated on screen) to freeze the current measurement reading on the display. Press again to release.

5.5. Flipping the Screen Display

The screen display can be flipped for better viewing angles. Consult the device's on-screen menu or physical buttons for this function.

ZOYI ZT-MD1 LCR Meter Tweezer measuring various components

Image: The ZOYI ZT-MD1 LCR Meter Tweezer demonstrating its use in measuring capacitance, inductance, resistance, and continuity on different electronic components.

6. Étalonnage

6.1. User Calibration Learning Mode

The ZT-MD1 supports a user calibration learning mode. To perform user calibration, connect a known standard resistor to the tweezer tips and follow the on-screen instructions. This allows the device to adjust its readings for improved accuracy based on your specific reference.

6.2. Réinitialisation d'usine

If necessary, factory calibration data can be restored by performing a factory reset. This will revert all settings and calibration data to their original factory values. Consult the device's menu for the factory reset option.

7. Entretien

7.1. Nettoyage

Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure the tweezer tips are clean and free of debris for accurate contact.

7.2. Stockage

When not in use, store the ZT-MD1 in its provided storage bag to protect it from dust and physical damage. Store in a cool, dry place away from direct sunlight and extreme temperatures.

7.3. Entretien de la batterie

To prolong battery life, avoid fully discharging the device frequently. Recharge the battery when the low battery indicator appears. If storing for an extended period, charge the battery to approximately 50% and recharge every few months.

8. Dépannage

ProblèmeCause possibleSolution
L'appareil ne s'allume pas.La batterie est épuisée.Connect the device to a 5V/A USB charger using the provided Type-C cable and allow it to charge for at least 30 minutes before attempting to power on again.
Lectures inexactes.Dirty or loose tweezer tips; device needs calibration.Ensure tweezer tips are clean and securely attached. Perform user calibration with a known standard resistor. If issues persist, consider a factory reset.
L'écran est vide ou ne répond pas.Appareil bloqué ; batterie faible.Try pressing and holding the power button for 10 seconds to force a restart. Ensure the battery is charged.
Cannot connect to PC for data export.Incorrect cable or driver issues.Ensure you are using the provided USB data cable. Check PC device manager for driver installation. Try a different USB port.

9. Spécifications

ParamètreValeur
Modèle de produitZOYI ZT-MD1
Gamme de capacité1 pF - 20 mF
Plage d'inductance1µH - 60H
Plage de résistance1 mΩ - 10 MΩ
Test de diodeLe voltaget 0.7V
Test de fréquence100 Hz, 1 kHz, 10 kHz
Test de niveau0.3 V, 0.6 V RMS
Affichage des paramètresL, C, R, D, Q, RS
Afficher1.14'' Color OLED Screen
Interface de chargementType-C, 5V/A
Alimentation électriqueBatterie au lithium 400 mAh
Mesure de reconnaissance automatiqueSoutenu
Tête de pince remplaçableSoutenu
Arrêt automatiqueSoutenu
Conservation des donnéesSoutenu
Enregistrement de l'historiqueSe connecter au PC view et export
Languechinois, anglais
Dimensions (L x l x H)146 x 30 x 18 mm
Poids de l'article170 g

10. Garantie et assistance

10.1. Informations sur la garantie

ZOYI products are manufactured to high-quality standards. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official ZOYI webConsultez le site. Conservez votre reçu d'achat comme preuve d'achat pour toute réclamation au titre de la garantie.

10.2. Assistance clientèle

If you encounter any issues or have questions regarding your ZOYI ZT-MD1 LCR Meter Tweezer that are not addressed in this manual, please contact ZOYI customer support. Contact details can typically be found on the product packaging, the official ZOYI websur le site, ou auprès de votre détaillant.

© 2024 ZOYI. Tous droits réservés.

Ce manuel peut être modifié sans préavis.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.