TRAÇABLE AO-94460-07

Traceable Excursion-Trac Data Logging Thermometer User Manual

Model: AO-94460-07

1. Introduction

The Traceable Excursion-Trac Data Logging Thermometer is designed for precise and reliable temperature monitoring and data logging. This device is ideal for applications requiring continuous temperature tracking and historical data retrieval. It features a clear LCD display, alarm functions, and the ability to log a significant number of temperature observations.

Traceable Excursion-Trac Data Logging Thermometer with bottle probe and USB drive.

Devant view of the Traceable Excursion-Trac thermometer, showing the main display, control buttons, connected bottle probe, and a USB flash drive for data transfer.

2. Installation

2.1 Déballage

Déballez soigneusement tous les composants. Le colis devrait contenir :

  • Traceable Excursion-Trac Data Logging Thermometer unit
  • 1 Bottle Probe
  • 2 piles AAA
  • Manuel d'instructions (ce document)

2.2 Installation de la batterie

  1. Localisez le compartiment à piles à l'arrière du thermomètre.
  2. Ouvrez le couvercle du compartiment.
  3. Insérez deux (2) piles AAA, en veillant à respecter la polarité (+/-).
  4. Close the battery compartment cover securely. The device will power on automatically.

2.3 Connexion de la sonde

Connect the bottle probe cable to the designated probe input port (labeled P1 or P2) on the side of the thermometer unit. Ensure the connection is firm.

Dos view of Traceable Excursion-Trac thermometer with kickstand.

Arrière view of the thermometer, illustrating the integrated kickstand for desktop placement and wall-mount slot.

3. Mode d'emploi

3.1 Mise sous/hors tension

The device powers on automatically upon battery installation. To turn off the device, remove the batteries. For temporary power saving, some models may have an ON/OFF switch for the alarm or display backlight, but the main unit remains active for logging.

3.2 Affichage terminéview

L'écran LCD affiche diverses informations :

  • Température actuelle : The primary reading from the connected probe(s).
  • MIN MAX: Minimum and maximum temperatures recorded since the last reset.
  • MEM : Indicates memory status or data logging activity.
  • ALARME: Indicates alarm status (active, triggered).
  • DATE / HEURE: Current date and time for logged events.
Traceable Excursion-Trac thermometer displaying current date and time.

The thermometer display showing the current date and time, indicating its time-keeping functionality for logged data.

3.3 Sélection de l'unité (°C/°F)

Appuyez sur le UNITÉS button to toggle between Celsius (°C) and Fahrenheit (°F) temperature scales.

3.4 Viewing Min/Max/Date/Time

Appuyez sur le MIN/MAX/ALARM-DATE/TIME button to cycle through the minimum temperature, maximum temperature, and current date/time displays. The display will show the recorded minimum and maximum temperatures since the last reset.

3.5 Fonction d'alarme

The thermometer features programmable high and low alarms. When the temperature exceeds or falls below the set limits, an audible and visual alarm will activate.

  1. Réglage des alarmes : Utilisez le SELECT/ADVANCE et ALARM DATE SET buttons to navigate and adjust the high and low temperature thresholds. Refer to the on-screen prompts for specific steps.
  2. Alarme activée/désactivée : Utilisez le ALARME ON / OFF switch to enable or disable the alarm function.
  3. Silence d'alarme : Appuyez sur le SILENCE ALARME button to temporarily mute an active alarm.
  4. Event Display: Le EVENT DISPLAY button allows viewing of recorded alarm events. The device can store up to 10 individual alarm events.

3.6 Data Logging and Retrieval

The Excursion-Trac thermometer automatically logs temperature data. It can store up to 525,600 temperature observations. To retrieve logged data:

  1. Connect the thermometer to a computer using a standard USB cable (not always included, check package contents).
  2. Le périphérique doit apparaître comme un périphérique de stockage amovible.
  3. Access the logged data files (typically in a CSV or similar format) from the device's storage.
  4. Copiez le files to your computer for analysis.
Côté view of Traceable Excursion-Trac thermometer showing USB port.

Côté view of the thermometer, clearly showing the USB port for data transfer and the power input.

4. Entretien

4.1 Remplacement de la batterie

When the low battery indicator appears on the display, replace the two AAA batteries immediately. Ensure new batteries are inserted with correct polarity.

4.2 Nettoyage

Wipe the thermometer unit and probes with a soft, damp cloth. Do not use abrasive cleaners or immerse the main unit in liquids. The bottle probe is designed for use in various environments, including freezers.

4.3 Étalonnage

The Traceable Excursion-Trac thermometer is supplied with an individually calibrated and certified NIST-traceable certificate. For continued accuracy and compliance, periodic recalibration is recommended according to your facility's protocols or regulatory requirements.

5. Dépannage

  • "Battery Low" Message: Replace the two AAA batteries immediately. Ensure new batteries are inserted with correct polarity.
  • Lectures inexactes : Verify that the probe is securely connected to the unit. Ensure the probe is correctly positioned within the environment being monitored. Check for any visible damage to the probe cable or sensor.
  • Data Download Issues: Ensure the USB cable is properly connected to both the thermometer and the computer. Try a different USB port or cable. If the device does not appear as a removable drive, consult the manufacturer's support for specific driver or software requirements.
  • Pas d'affichage : Check battery installation and ensure batteries are not depleted. If the issue persists after replacing batteries, contact customer support.

6. Spécifications

Traceable Excursion-Trac thermometer with dimensions indicated.

An illustration of the thermometer with its physical dimensions and temperature range.

FonctionnalitéDétail
Numéro de modèleAO-94460-07
Précision±0.25°C
Plage de température-50°C à 70°C (-58°F à 158°F)
Résolution de la température0.01°
Type de sonde1 Bottle Probe
Capacité d'enregistrement des donnéesUp to 525,600 temperature observations
Type d'affichageLCD, 1/2"H digits
ConnectivitéUSB
Source d'énergie2 piles AAA
MatérielPlastique
Dimensions (H x L x P)10.79 cm x 6.98 cm x 1.9 cm (environ 4.25 po x 2.75 po x 0.75 po)
Caractéristiques spécialesHigh Accuracy, Min/Max Memory, Alarm Function, 3m Micro-Thin Cable, Integrated Stand, Wall Mount, Magnetic Strip

7. Garantie et assistance

For technical assistance, warranty claims, or further information regarding your Traceable Excursion-Trac Data Logging Thermometer, please contact your supplier or the manufacturer directly. Refer to your purchase documentation for specific warranty terms and contact details.

Ask a question about this manual