DARKROCK D240

DARKROCK D240 CPU Liquid Cooler Instruction Manual

1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of your DARKROCK D240 CPU Liquid Cooler. Please read this guide thoroughly before beginning installation to ensure proper setup and optimal performance. The DARKROCK D240 is an all-in-one (AIO) liquid cooling system designed to efficiently dissipate heat from your CPU, featuring a 240mm radiator, addressable RGB lighting, and a pure copper pump base.

DARKROCK D240 CPU Liquid Cooler installed in a PC case with RGB lighting

Image: The DARKROCK D240 CPU Liquid Cooler integrated into a computer system, showcasinet ses effets d'éclairage RGB.

2. Configuration et installation

2.1 Contenu du paquet

Avant l'installation, vérifiez que tous les composants sont présents dans l'emballage :

  • 1x Radiator with Integrated Pump and Tubing
  • 2x 120mm ARGB PWM Cooling Fans
  • Intel Mounting Bracket (LGA1851/1700/1200/115X)
  • Support de montage AMD (AM5/AM4)
  • Plaque arrière pour sockets Intel
  • Mounting Screws and Standoffs for Intel/AMD
  • Pâte thermique
  • Vis de ventilateur
  • 1 to 3 Fan Splitter Cable
  • RGB Controller (if included with your model)
All components included with the DARKROCK D240 CPU Liquid Cooler

Image : Une image détaillée view of all parts and accessories included in the DARKROCK D240 CPU Liquid Cooler package.

2.2 Étapes de pré-installation

  1. Préparez votre carte mère : Ensure your motherboard is compatible with the cooler. The D240 supports Intel LGA1851/1700/1200/115X and AMD AM5/AM4 sockets.
  2. Retirer l'ancien refroidisseur : Si vous remplacez un refroidisseur existant, retirez-le soigneusement et nettoyez toute trace de vieille pâte thermique de la surface du processeur à l'aide d'alcool isopropylique.
  3. Identify Mounting Hardware: Select the appropriate mounting bracket and screws for your CPU socket type (Intel or AMD).
Compatibility diagram showing AMD AM5/AM4 and Intel LGA1851/1700/1200/115X sockets

Image: Visual representation of the cooler's compatibility with various AMD and Intel CPU sockets.

2.3 Mounting the Radiator and Fans

  1. Attach the two 120mm fans to the radiator using the provided fan screws. Ensure the fan airflow direction is appropriate for your case (typically exhausting air out of the case).
  2. Mount the radiator assembly to an available 240mm fan mount in your PC case (e.g., top, front, or side).
Diagram showing 120mm PWM/ARGB cooling fans and radiator

Image: Illustration of the 120mm PWM/ARGB cooling fans and the radiator, highlighting their features.

Close-up of the radiator fin design for efficient heat transfer

Image : Un gros plan view of the radiator's fin structure, designed for optimal heat dissipation.

2.4 Installing the Pump Head

  1. Appliquez une petite quantité de pâte thermique au centre du dissipateur thermique intégré (IHS) de votre processeur.
  2. Attach the correct mounting bracket to the pump head. Ensure the protective film is removed from the copper base before installation.
  3. Carefully place the pump head onto the CPU, aligning the mounting holes with the standoffs on the motherboard.
  4. Secure the pump head with the thumb screws, tightening them in a diagonal pattern until snug. Do not overtighten.
Diagram showing the copper base of the pump and liquid flow through the tubes

Image: A visual representation of the pure copper base of the pump and the liquid circulation path.

2.5 Connexions de câblage

Connect the pump and fan cables to your motherboard or an RGB controller as follows:

  • Puissance de la pompe: Connect the pump's 3-pin or 4-pin connector to the dedicated AIO_PUMP or CPU_OPT header on your motherboard.
  • Puissance du ventilateur: Connect the fan cables to the 1-to-3 splitter cable, then connect the splitter to a CPU_FAN or SYS_FAN header on your motherboard.
  • Éclairage ARGB : Connect the ARGB cables from the fans and pump head to a 5V 3-pin ARGB header on your motherboard or to the included RGB controller. Ensure correct pin alignment to prevent damage.
  • RGB Controller Power: If using an RGB controller, connect it to a SATA power connector from your power supply.
Wiring diagram for connecting the CPU cooler pump, fans, and RGB lighting

Image: A comprehensive diagram illustrating the electrical connections for the pump, fans, and ARGB lighting.

2.6 Vidéo d'installation

Pour un guide visuel du processus d'installation, veuillez consulter la vidéo d'installation officielle :

Video: Official installation guide for the DARKROCK D240 and D360 liquid cooling systems, demonstrating steps for both AMD and Intel platforms.

3. Mode d'emploi

3.1 Mise sous tension initiale

After completing the installation and wiring, power on your computer. The fans and pump should start operating, and the ARGB lighting should illuminate. Monitor your CPU temperatures using system monitoring software to ensure proper cooling.

3.2 Contrôle de l'éclairage ARGB

The DARKROCK D240 features addressable RGB lights on both the fans and the water-cooling head. These can be controlled via:

  • Logiciel de la carte mère : If connected to a compatible 5V 3-pin ARGB header, you can synchronize and customize lighting effects using your motherboard's RGB software (e.g., ASUS Aura Sync, MSI Mystic Light Sync, Gigabyte RGB Fusion, ASRock Polychrome Sync).
  • Contrôleur RGB inclus : If your model includes a dedicated RGB controller, use its buttons or remote control to cycle through various lighting modes, colors, and effects.
PC interior showcasing vibrant addressable RGB lighting effects from the cooler

Image: A computer case interior illuminated by the customizable addressable RGB lighting of the DARKROCK D240 cooler and other components.

RGB controller and remote for managing lighting effects

Image: The RGB controller and its remote, used for adjusting the cooler's lighting effects.

3.3 PWM Smart Control

The adjustable PWM fans (800 RPM - 1800 RPM) automatically adjust their speed based on CPU temperature. This provides efficient cooling when needed and reduces noise during lighter loads. You can often fine-tune fan curves through your motherboard's BIOS settings or dedicated software.

3.4 Vidéo de présentation du produit

Observe the DARKROCK D240 in action with its dynamic RGB lighting and cooling capabilities:

Video: A showcase of the DARKROCK D240 CPU Liquid Cooler, highlighting its design and various RGB lighting modes within a PC build.

4. Entretien

Un entretien régulier contribue à assurer la longévité et les performances optimales de votre système de refroidissement liquide :

  • Nettoyage de la poussière : Nettoyez régulièrement les ailettes du radiateur et les pales du ventilateur pour éviter l'accumulation de poussière, qui peut entraver la circulation de l'air et réduire l'efficacité du refroidissement. Utilisez de l'air comprimé ou une brosse douce.
  • Inspecter les tubes et les raccords : Occasionally check the tubing for any signs of leaks or kinks. Ensure all electrical connections are secure.
  • Pâte thermique : While not frequently required, if you ever remove the pump head from the CPU, you will need to clean off the old thermal paste and apply new paste before reinstallation.

5. Dépannage

If you encounter issues with your DARKROCK D240 CPU Liquid Cooler, consider the following:

  • Pas d'alimentation/pas de lumière :
    • Check all power connections (pump, fans, RGB controller) to ensure they are securely plugged in.
    • Verify that the motherboard headers are supplying power (check BIOS settings).
    • If using an RGB controller, ensure it is receiving SATA power.
  • Températures élevées du processeur :
    • Confirm the pump is running (you might feel a slight vibration or hear a low hum).
    • Ensure the pump head is securely mounted to the CPU and thermal paste was applied correctly.
    • Check fan operation and ensure they are spinning and providing adequate airflow.
    • Nettoyez les ailettes du radiateur pour enlever toute trace de poussière.
  • Bruit anormal :
    • Déterminez si le bruit provient des ventilateurs ou de la pompe.
    • For fans, check for obstructions or loose mounting.
    • For pump noise, ensure it's not running dry (though unlikely with a sealed AIO).
  • RGB Not Working/Incorrect Colors:
    • Verify the ARGB cables are connected to a 5V 3-pin header, not a 12V 4-pin RGB header, as this can cause damage.
    • Check motherboard RGB software settings or RGB controller mode.
    • Ensure all ARGB connections are firm.

6. Spécifications

FonctionnalitéDétail
Dimensions du produit10.7"L x 4.7"l x 1.1"H
MarqueROCHE NOIRE
Type de connecteur d'alimentation4 broches
Voltage5 volts
Méthode de refroidissementEau
Appareils compatiblesBureau
Niveau de bruit30 décibels
MatérielAluminium, Cuivre
Vitesse de rotation maximale3000 RPM (Pump) / 1800 RPM (Fans)
Poids de l'article3.96 livres
Numéro de modèleD240

7. Garantie et assistance

For warranty information and technical support, please refer to the official DARKROCK webConsultez leur site web ou contactez leur service client. Conservez votre preuve d'achat pour toute réclamation au titre de la garantie.

Optional protection plans may be available for extended coverage. Please check with your retailer for details on available protection plans.

Ask a question about this manual