Introduction
This manual provides instructions for the proper use and care of your BIOWAVE BioWrap Back Brace Lumbar Support. This device is designed to provide lumbar support and facilitate the integration of a BioWaveGO TENS unit for muscle stimulation and pain relief. Please read this manual thoroughly before initial use.

Image illustrating common areas of back pain and related discomfort where the BioWrap may be applied.
Consignes de sécurité
Important: The BioWrap Back Brace is intended for use with the BioWaveGO TENS Unit (sold separately). Do not use this product without consulting a healthcare professional if you have pre-existing medical conditions, are pregnant, or have implanted electronic devices.
- Ensure electrodes are properly attached and skin is clean before use.
- Do not apply electrodes over open wounds, rashes, or irritated skin.
- Tenir hors de portée des enfants.
- Cesser l'utilisation en cas d'irritation ou d'inconfort.
Contenu du colis
Vérifiez que tous les éléments sont présents dans votre colis :
- 1 x BIOWAVE BioWrap Back Brace (S/M)
- 4 x Electrode Pads (for use with BioWaveGO)
Note: The BioWaveGO TENS Unit is required for electrical stimulation and is sold separately.

Image showing the BioWrap Back Brace, electrode pads, and the BioWaveGO device (indicated as a separate purchase).
Spécifications du produit
| Fonctionnalité | Détail |
|---|---|
| Marque | BIOWAVE |
| Modèle | BioWrap Back Brace |
| Taille | S/M (For Waist Size 28”-38”) |
| Material (Inside) | Néoprène |
| Material (Outside) | Tricote |
| Compatibilité | BioWaveGO TENS Unit |
| Utilisations spécifiques | Lumbar Support, Sciatica, Back Pain Relief |
Configuration et application
Follow these steps to properly set up and apply your BioWrap Back Brace with the BioWaveGO TENS Unit.
- Prepare Electrodes: Place the Velcro-backed side of each electrode pad directly onto the designated areas on the inside of the BioWrap. Ensure a secure attachment.
- Connect Leadwires: Plug the blue pad connectors into the blue leadwire cable connectors from your BioWaveGO device.
- Positionnez le renfort : Wrap the BioWrap around your lower back, ensuring it is centered and comfortable. Pull tight to achieve a snug fit.
- Fixez l'attelle : Attach the main Velcro closure over the left side. Unhook any secondary straps and pull them down to further tighten the BioWrap for optimal compression and electrode contact.
- Connect to BioWaveGO: Plug the single end of the cable into your BioWaveGO device.
- Power On and Adjust: Power on your BioWaveGO device. Press the '+' button to increase intensity and control your comfort level.

Visual guide for applying electrodes, connecting the BioWaveGO, and wearing the BioWrap brace.
Mode d'emploi
Once the BioWrap Back Brace is properly applied and connected to the BioWaveGO TENS Unit, you can begin your therapy session.
- Démarrage d'une session : Refer to your BioWaveGO TENS Unit manual for specific instructions on initiating a therapy session. Typically, a session lasts 30 minutes.
- Réglage de l'intensité : Use the controls on your BioWaveGO device to adjust the intensity of the electrical stimulation to a comfortable yet effective level.
- Monitoring Comfort: The sensation should be a deep, soothing massage, not painful. If you experience any discomfort, reduce the intensity or discontinue use.
- Utilisation portable : The BioWrap is designed for mobility. You can wear it during light activities.

The BioWrap Back Brace allows for mobility during use.
Entretien et soins
- Cleaning the Brace: Hand wash the BioWrap Back Brace with mild soap and cold water. Air dry completely. Do not machine wash, tumble dry, bleach, or iron.
- Entretien des électrodes : Replace electrode pads when they lose their adhesiveness or if you notice reduced effectiveness. Always apply electrodes to clean, dry skin.
- Stockage: Store the BioWrap and electrodes in a cool, dry place away from direct sunlight.
Dépannage
| Problème | Cause possible | Solution |
|---|---|---|
| Aucune sensation ou sensation faible | Electrodes not making good contact; Electrodes worn out; BioWaveGO device not powered on or faulty connection. | Re-position electrodes, ensure skin is clean; Replace electrodes; Check BioWaveGO power and cable connections. |
| Irritation cutanée | Electrodes applied to irritated skin; Allergic reaction; Overuse. | Discontinue use immediately; Consult a healthcare professional; Ensure skin is clean and dry before application. |
| Brace feels too loose or too tight | Incorrect sizing or improper application. | Adjust Velcro straps for a snug, comfortable fit. Ensure correct size was purchased (S/M for 28”-38” waist). |
Garantie et assistance
For information regarding warranty coverage for your BIOWAVE BioWrap Back Brace, please refer to the documentation included with your purchase or visit the official BIOWAVE website.
For customer support, technical assistance, or to purchase replacement parts, please contact BIOWAVE directly through their official channels.
- Fabricant: BioVague
- Boutique de la marque : BIOWAVE Amazon Store