Introduction
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Metabo TBP 6200/8 INOX submersible borehole pump. Please read these instructions carefully before using the pump for the first time. Keep this manual in a safe place for future reference.
Consignes de sécurité
Respectez toujours les consignes de sécurité suivantes afin d'éviter les blessures et les dommages matériels :
- Vérifiez que l'alimentation électrique correspond aux spécifications indiquées sur la plaque signalétique de la pompe.
- Never operate the pump without water. Dry running can cause severe damage.
- Do not use the power cable to lift or lower the pump. Always use a suitable rope or chain.
- Débranchez la pompe de l'alimentation électrique avant toute opération de maintenance ou de nettoyage.
- Tenir les enfants et les personnes non autorisées à l'écart de la pompe en fonctionnement.
- Assurez-vous d'une mise à la terre correcte de la connexion électrique.
- Do not pump flammable, explosive, or corrosive liquids.
Installation
1. Déballage et inspection
Carefully remove the pump from its packaging. Inspect the pump for any signs of damage that may have occurred during transit. If any damage is found, do not use the pump and contact your supplier.
2. Attaching the Suspension Rope
Attach a strong, non-stretchable rope or chain to the designated eyelets on the pump. This rope will be used to lower and retrieve the pump from the borehole. Ensure the knot is secure.

Image: Securely tying a suspension rope to the pump's attachment point. This rope is crucial for safe installation and retrieval of the pump from the borehole.
3. Connecting the Discharge Hose/Pipe
Connect a suitable discharge hose or pipe to the pump's outlet. Ensure all connections are tight and leak-free. Use appropriate sealing materials if necessary.

Image: Connecting the discharge hose to the pump. Proper sealing ensures efficient water transfer and prevents leaks.
4. Lowering the Pump into the Borehole
Carefully lower the pump into the borehole using the attached suspension rope. Ensure the pump is fully submerged and positioned correctly, avoiding contact with the bottom or sides of the well to prevent sediment intake or damage.

Image: Lowering the submersible pump into a borehole. The pump must be fully submerged for proper operation.
5. Connexion électrique
Connect the pump's power cable to a suitable, grounded electrical outlet. Ensure the circuit is protected by a residual current device (RCD) for safety.
Mode d'emploi
1. Démarrage de la pompe
Once the pump is fully submerged and all connections are secure, switch on the power supply. The pump will begin to draw water. Monitor the initial operation for any unusual noises or vibrations.
2. Monitoring Operation
Regularly check the water flow and pressure. If the flow decreases significantly or the pump makes unusual noises, switch it off immediately and investigate the cause.

Image: The pump in operation, supplying water for garden irrigation. Ensure consistent water flow during use.

Image: The pump effectively powering a sprinkler system for garden watering, demonstrating its application.
3. Arrêt
To stop the pump, simply switch off the power supply. If the pump will not be used for an extended period, disconnect it from the power source and follow the maintenance and storage guidelines.
Entretien
1. Nettoyage régulier
Periodically remove the pump from the borehole and clean its exterior, especially the intake screen, to prevent blockages. Use clean water and a soft brush. Do not use harsh chemicals.
2. Hivernage
In regions with freezing temperatures, remove the pump from the borehole before winter. Drain all water from the pump and hoses to prevent damage from freezing. Store the pump in a dry, frost-free location.
3. Stockage
When not in use, store the pump in a clean, dry, and well-ventilated area, protected from direct sunlight and extreme temperatures.
Dépannage
| Problème | Cause possible | Solution |
|---|---|---|
| La pompe ne démarre pas | Pas d'alimentation électrique Surcharge thermique activée Turbine bloquée | Vérifiez le raccordement électrique et le disjoncteur. Laisser la pompe refroidir Coupez l'alimentation et dégagez les obstructions. |
| Débit d'eau réduit | Grille d'admission bouchée Tuyau plié ou bloqué Niveau d'eau bas dans le puits | Filtre d'admission propre Check and clear hose Wait for water level to rise or reposition pump |
| La pompe fonctionne mais il n'y a pas d'eau. | Pompe pas complètement immergée Air dans le système clapet anti-retour défectueux | Ensure pump is submerged Purger l'air du système Inspect or replace check valve |
| Bruit/vibrations excessifs | Corps étranger dans la pompe Roulements usés Pump touching well walls | Disconnect power and inspect impeller Contactez un personnel de service qualifié Adjust pump position |
Caractéristiques

Image: The Metabo TBP 6200/8 INOX submersible pump. Its robust stainless steel construction is designed for durability.
- Numéro de modèle : 610217000
- Dimensions (L x l x H) : 45 x 24 x 24 cm
- Poids: 9.3 kilogrammes
- Matériel: Acier inoxydable
- Power (Motor): 1100 watts
- Source d'alimentation : Câble électrique
- Fabricant: Métabo
- Pays d'origine : Allemagne
Courbe de performance

Image: Performance curve for the TBP 6200/8 INOX pump. This graph illustrates the relationship between flow rate, head, and pressure, indicating the pump's operational capabilities under various conditions.
Garantie et assistance
For warranty information, technical support, or spare parts, please contact your authorized Metabo dealer or visit the official Metabo webConsultez le site. Conservez votre reçu d'achat comme preuve d'achat.