EMKE THE3-ADVC

EMKE 300W Bathroom Radiator Heating Element User Manual

Model: THE3-ADVC

1. Informations importantes sur la sécurité

Please read this manual carefully before installation and operation. Keep it for future reference. Failure to follow these instructions may result in electric shock, fire, or injury.

  • Ensure the power supply matches the specifications of the heating element.
  • Installation must be performed by a qualified electrician or competent person in accordance with local wiring regulations.
  • Do not operate the heating element if the cable or plug is damaged.
  • Do not immerse the heating element or its control unit in water.
  • Tenir les enfants éloignés de l'appareil pendant son fonctionnement.
  • The heating element must always be installed at the bottom of the bathroom radiator.
  • Ensure the radiator is filled with liquid before operating the heating element.

2. Produit terminéview

The EMKE 300W Bathroom Radiator Heating Element is designed to provide efficient and controlled heating for your bathroom radiator, allowing for towel drying and ambient warmth. It features a digital display and intelligent thermostat for precise temperature management.

EMKE 300W Bathroom Radiator Heating Element with digital display and coiled power cord

Figure 2.1: The EMKE 300W Heating Element, showing the main unit with its digital display and the coiled power cord leading to a standard plug.

Close-up of the heating element's digital display and control buttons, with a hand pointing to it, illustrating human-centric design.

Figure 2.2: Close-up of the control panel, highlighting the user-friendly design with an angled screen for easy viewing et fonctionnement.

3. Spécifications

FonctionnalitéSpécification
Pouvoir300 W
Dimensions (Heating Element)385 x Φ12 mm
Longueur du câble1400-1500 mm
Voltage230V ± 10%
Indice d'étanchéitéIPx4
Plage de température réglable7-70 °C (Ambient) / 30-70 °C (Electronic Thermostat)
Main Material (Thermostat)ABS
Main Material (Heating Element)Acier inoxydable 304
Fil de connexionG1/2 pouce
Numéro de modèleTHE3-ADVC
Diagram showing recommended heating element power based on radiator heat output, with corresponding heating element dimensions.

Figure 3.1: Guide for selecting the correct heating element power and physical dimensions (in mm).

4. Installation (Configuration)

The installation of the heating element is designed to be straightforward and can be performed at home. However, if you are unsure, consult a qualified professional.

  1. Contrôle de compatibilité: Ensure your bathroom radiator has a G1/2 inch connection thread. The 300W heating element is suitable for bathroom radiators with a power output between 300-600 watts.
  2. Positionnement : The heating element must always be installed at the bottom of the bathroom radiator. This ensures proper heat distribution and safe operation.
  3. Filling the Radiator: Before installing the heating element, ensure the radiator is properly filled with the appropriate liquid (e.g., water or heat transfer fluid) according to your radiator's instructions.
  4. Installation sécurisée : Carefully screw the heating element into the G1/2 inch port at the bottom of the radiator. Ensure it is tightened securely to prevent leaks.
  5. Connexion électrique : Plug the coiled power cord into a suitable 230V ± 10% electrical outlet. The cable length is approximately 1400-1500 mm.
  6. Précaution de sécurité : For safety reasons, the heating element does not heat up within 3-4 cm of the power supply connection point.
EMKE electric heating rod with thermostat installed on a white bathroom radiator.

Figure 4.1: The electric heating element with thermostat correctly installed on a bathroom radiator.

White bathroom radiator with the heating element installed, in a modern bathroom setting with a basket of rolled towels.

Figure 4.2 : Un example of the heating element integrated into a modern bathroom radiator setup.

5. Fonctionnement

The EMKE heating element features intelligent temperature control with six distinct operating modes, allowing for precise temperature management from 30 °C to 70 °C. The digital display provides real-time information on current temperature and settings.

Diagram illustrating the six operating modes of the heating element's thermostat, with icons and temperature ranges.

Figure 5.1 : Plusview of the six operating modes and their respective settings.

Modes de fonctionnement :

  • Mode économie : Standard temperature is 15 °C. Adjustable range is 7-30 °C.
  • Mode Confort : Standard temperature is 19 °C. Adjustable range is 7-30 °C.
  • Mode hors gel : Temperature is fixed at 7 °C and is not adjustable.
  • Mode Boost : Allows for 30 minutes to 24 hours of continuous heating.
  • Mode minuterie : Can be set to heat at regular intervals.
  • Mode Vacances : Allows you to set the device's temperature when you are away and specify the number of days you will be gone.

Fonction de verrouillage enfant :

The thermostatic heating rods are equipped with a touch protection program (child lock function) to ensure a safe environment. Refer to the device's specific instructions for activating and deactivating the child lock.

Image showing the heating element installed on a white bathroom radiator, with text indicating a child lock function.

Figure 5.2: The heating element features a child lock function for enhanced safety.

6. Entretien

Regular maintenance ensures the longevity and efficient operation of your EMKE heating element.

  • Nettoyage: Disconnect the power before cleaning. Wipe the exterior of the heating element and control unit with a soft, damp chiffon. N'utilisez pas de nettoyants abrasifs ou de solvants.
  • Inspection: Periodically check the power cord for any signs of damage. Ensure the connection to the radiator is secure and free from leaks.
  • Niveau de liquide : Ensure the liquid level in your radiator is maintained as per the radiator manufacturer's guidelines.

7. Dépannage

If you encounter issues with your EMKE heating element, refer to the following common solutions:

  • Pas d'alimentation : Check if the power plug is securely inserted into the outlet. Verify that the circuit breaker has not tripped.
  • Pas de chauffage : Ensure the desired temperature is set above the current room temperature. Check if the heating element is in an active heating mode (e.g., Comfort, Boost). Verify the radiator is filled with liquid.
  • Problèmes d'affichage : If the digital display is not functioning correctly, try unplugging the unit for a few minutes and then plugging it back in to reset it.
  • Fuites : If you notice any leaks, immediately disconnect power and tighten the connection thread. If the leak persists, contact customer support.

For persistent problems or issues not covered here, please contact EMKE customer support.

8. Garantie et assistance

EMKE provides comprehensive services to ensure a smooth experience with your product.

  • Politique de retour: Une politique de retour de 14 jours est offerte.
  • Service de réparation: Le produit inclut un service de réparation de 2 ans.
  • Assistance clientèle : If you have any questions or require assistance, please contact EMKE customer service. Contact details can typically be found on the product packaging or the official EMKE website.