Wedinard W218

Wedinard Water Quality Monitor W218 User Manual

Modèle: W218

Brand: Wedinard

Introduction

The Wedinard W218 Water Quality Monitor is an advanced 8-in-1 wireless WiFi remote monitoring device designed for comprehensive water quality analysis. This instrument provides real-time data reception and automatic data storage, making it suitable for continuous monitoring in various environments.

Les principales caractéristiques comprennent :

  • 24-hour online monitoring capability.
  • Compatibility with iOS and Android systems for mobile app control.
  • Automatic language conversion based on mobile settings.
  • Wireless WiFi remote monitoring with multi-parameter testing.
  • Automatic correction and data storage for up to 30 days.

Composants du produit

Wedinard Water Quality Monitor components

Figure 1 : Surview of the Wedinard Water Quality Monitor and its included components. This image displays the main unit, various probes (pH, ORP, EC/TDS/SALT/CF), power adapter, and connection cables.

Le forfait comprend généralement :

  • Main Monitoring Unit (W218)
  • Sonde de pH
  • Sonde redox
  • EC/TDS/SALT/CF Probe
  • Temperature Probe (often integrated with pH/EC)
  • Power Adapter (EU Plug 230V)
  • Câble USB
  • Suction Cups for probe mounting

Instructions d'installation

  1. Déballage: Retirez soigneusement tous les composants de leur emballage. Vérifiez qu'ils ne présentent aucun dommage visible.
  2. Connexion de la sonde :
    Close-up of pH and ORP probe connection ports

    Figure 2 : Gros plan view of the pH and ORP probe input ports on the main unit, showing the BNC connectors.

    Connect the pH, ORP, and EC/TDS/SALT/CF probes to their respective ports on the main unit. Ensure connections are secure. The pH and ORP probes typically use BNC connectors.
  3. Connexion électrique : Plug the provided power adapter into the main unit and then into a standard 230V EU power outlet. The device will power on automatically.
  4. Placement de la sonde : Submerge the probes into the water body you wish to monitor. Ensure the probes are fully immersed and stable. Use the provided suction cups if necessary to secure them.
  5. Installation de l'application : Download the official Wedinard water quality monitoring app from your mobile device's app store (compatible with iOS and Android).
  6. Connexion Wifi: Open the app and follow the on-screen instructions to connect the device to your local WiFi network. This typically involves entering your WiFi credentials.

Mode d'emploi

Wedinard Water Quality Monitor display showing readings

Figure 3 : The main unit display showing real-time readings for pH/Temperature, ORP, and EC/TDS/SALT/CF parameters.

  1. Surveillance en temps réel : Once powered on and connected, the device will immediately begin displaying real-time readings on its integrated LCD screen for pH, ORP, EC, TDS, Salt, CF, and Temperature.
  2. Interface de l'application :
    Wedinard Water Quality Monitor integrated into an aquarium setup

    Figure 4 : The Wedinard Water Quality Monitor in an aquarium setting, demonstrating its application for continuous monitoring.

    Access the mobile app to view detailed data, historical trends, and configure settings. The app allows for remote monitoring from anywhere with an internet connection.
  3. Stockage des données : The device automatically stores data for up to 30 days. This historical data can be accessed and analyzed through the mobile application. To view specific parameter details (e.g., pH), click on the corresponding section within the app to see daily, weekly, or monthly trends.
  4. Parameter Calibration:
    Wedinard Water Quality Monitor calibration screen

    Figure 5 : The calibration interface on the Wedinard Water Quality Monitor, indicating options for pH, ORP, and EC/TDS/SALT/CF calibration.

    The device supports automatic correction. For accurate readings, periodic calibration of probes is recommended. Refer to the app or device manual for specific calibration procedures using standard buffer solutions. pH calibration typically involves 3 points (e.g., 6.86, 4.00, 9.18 or 7.00, 4.00, 10.00).

Entretien

  • Nettoyage de la sonde : Regularly clean the probes to prevent buildup that can affect accuracy. Use distilled water or a mild cleaning solution recommended for pH/ORP/EC probes. Avoid abrasive materials.
  • Rangement de la sonde : When not in use for extended periods, store pH and ORP probes in their respective storage solutions or a 3M KCl solution to prevent drying out.
  • Étalonnage: Calibrate the probes regularly, especially if readings appear inconsistent or after prolonged use. Frequency depends on usage and application.
  • Nettoyage des unités : Essuyez l'unité principale avec un chiffon doux, damp tissu. Ne plongez pas l’unité principale dans l’eau.
  • Mises à jour logicielles : Check the mobile app periodically for firmware updates for the device to ensure optimal performance and access to new features.

Dépannage

ProblèmeCause possibleSolution
L'appareil ne s'allume pas.Adaptateur secteur non connecté ou défectueux ; problème de prise électrique.Ensure power adapter is securely connected. Test the power outlet with another device. Try a different power adapter if available.
Impossible de se connecter au Wi-Fi.Incorrect WiFi password; device too far from router; router settings.Double-check WiFi password. Move the device closer to the router. Ensure your router supports 2.4GHz WiFi (most IoT devices do not support 5GHz). Restart router and device.
Lectures inexactes.Probes are dirty or damaged; probes require calibration; expired calibration solution.Clean probes thoroughly. Perform a full calibration using fresh calibration solutions. Inspect probes for physical damage. Replace probes if necessary.
L'application n'affiche pas de données.No internet connection; app not synced with device; app bug.Verify your mobile device has an internet connection. Ensure the device is connected to WiFi. Restart the app. Reinstall the app if issues persist.
Data not saving for 30 days.Device storage issue; app synchronization problem.Ensure continuous power supply and WiFi connection. Check app settings for data retention. Contact support if the issue persists.

Caractéristiques

ParamètreGammeRésolutionPrécision
pHpH 0.00-14.000.01PH± 0.03 pH
ORP-2000mv ~ +2000mv1mv±5mv
EC0-19000us/cm, 0-199.0 ms/cm1us/cm (>1999us/cm), 0.1ms/cm± 2 % FS
CF0-1999.0CF1CF± 2 % FS
TDS0-19990ppm, 0-199.0ppt1 ppm (>1999ppm), 0.1 percentagle point± 2 % FS
Sel0-199.9ppt, 0%-20%1ppm (>1999ppm), 0.1 percentage point, 0.01%± 2 % FS
SG0.990-1.4000.001N / A
Température0-50°C (32°F~122°F)0.1°C (0.2°F)±1.0°C

Autres spécifications :

  • Batterie: 6 V CC
  • Compensation de température : 0°C-50°C
  • Température de fonctionnement : 0°C-50°C
  • Dimensions du produit : Dimensions approximatives : 152 x 80 x 26 mm / 6.0 x 3.1 x 1.0 pouces
  • Fabricant: Wedinard
  • Numéro de modèle : KFI-GT-5.2lk-267169

Applications

Diagram showing various applications of water quality monitor

Figure 6 : Visual representation of the wide range of applications for the Wedinard Water Quality Monitor, including drinking water, swimming pools, fish tanks, water treatment, irrigation, and laboratories.

The Wedinard Water Quality Monitor is suitable for a wide range of applications, including but not limited to:

  • Aquariums and Glass Fish Ponds
  • Mining operations
  • Recherche médicale
  • Agriculture (e.g., irrigation water)
  • Laboratoires
  • General Water Environment monitoring
  • Quality Control processes
  • Drinking Water analysis
  • Piscines
  • Water Treatment facilities

Garantie et assistance

For warranty information and technical support, please refer to the official Wedinard webConsultez leur site web ou contactez directement leur service client. Conservez votre reçu d'achat comme preuve d'achat pour toute réclamation au titre de la garantie.

For further assistance, you may also refer to the product listing on Amazon.in for updated support contact details or FAQs.

© 2023 Wedinard. All rights reserved.

Ce manuel est fourni à titre informatif uniquement. Les spécifications peuvent être modifiées sans préavis.

Ask a question about this manual