1. Introduction
This manual provides essential information for the safe and efficient operation, setup, and maintenance of your TOTAL Lithium-ion Air Compressor, model TACLI2003. Please read this manual thoroughly before using the compressor and retain it for future reference.
2. Consignes de sécurité
Respectez toujours les consignes de sécurité de base afin de réduire les risques d'incendie, d'électrocution et de blessures corporelles lors de l'utilisation de ce produit.
- Lisez toutes les instructions: Familiarisez-vous avec les commandes et le bon usage du compresseur.
- Zone de travail: Gardez votre espace de travail propre et bien éclairé. Les zones encombrées ou sombres invitent les accidents.
- Sécurité électrique : This unit operates on 40V (2x20V) lithium-ion batteries. Ensure batteries and charger (not included) are compatible with TOTAL 20V tools. Do not expose the compressor to rain or wet conditions.
- Sécurité personnelle : Always wear eye protection. Use hearing protection when operating the compressor for extended periods. Do not overreach; maintain proper footing and balance at all times.
- Compressor Use and Care: Do not operate the compressor if the power switch does not turn it on and off. Disconnect the battery pack before making any adjustments, changing accessories, or storing the compressor. Store idle compressors out of the reach of children and do not allow persons unfamiliar with the compressor or these instructions to operate it.
- Sécurité sous pression : Never exceed the maximum pressure rating of any accessory or item being inflated. The maximum pressure for this compressor is 9.3 bar (135 psi).
- Entretien: Have your compressor serviced by a qualified repair person using only identical replacement parts. This will ensure that the safety of the power tool is maintained.
3. Contenu du colis
Upon unpacking, ensure all items listed below are present and undamaged. If any parts are missing or broken, please contact your retailer.
- TOTAL Lithium-ion Air Compressor (TACLI2003)
- 1 pc Steel Ball / Air Needle
- 1 pc Plastic Ball Needle
- 1 pc Schrader Presta Valve Adaptor
Note: Batteries and charger are not included with this unit and must be purchased separately.
4. Produit terminéview

Figure 1 : Avant gauche view of the TOTAL Lithium-ion Air Compressor TACLI2003, showcasing the main unit, 6L tank, and control panel with gauges.

Figure 2 : Close-up of the compressor's control panel, featuring two pressure gauges (tank and output), a power switch, and a pressure regulator knob.

Figure 3 : Détaillé view of the pressure gauges and the adjustable pressure regulator knob, allowing precise control over air output.

Figure 4 : Another close-up of the pressure regulator knob, which is used to set the desired output air pressure.

Figure 5 : Côté view showing the two battery compartments designed for 20V TOTAL lithium-ion batteries (not included).

Figure 6 : Arrière view of the compressor, highlighting the integrated storage compartment for various nozzles and adaptors.

Figure 7 : Close-up of the accessory storage, showing the included steel ball/air needle, plastic ball needle, and Schrader Presta valve adaptor.

Figure 8 : Detail of the pressure relief valve, an important safety feature designed to release excess pressure from the tank.
5. Installation
5.1 Installation de la batterie
- Ensure the compressor's power switch is in the 'OFF' position.
- Locate the two battery compartments on the side of the compressor (refer to Figure 5).
- Insert two fully charged TOTAL 20V lithium-ion batteries (2.0Ah or 4.0Ah compatible) into the compartments until they click securely into place.
- To remove batteries, press the release tabs on each battery and pull them out.
5.2 Accessoires de connexion
- Identify the quick-connect air outlet on the compressor.
- Select the appropriate accessory (e.g., air needle, valve adaptor) for your task.
- Attach the accessory to an air hose (not included) and then connect the air hose to the compressor's air outlet. Ensure a secure connection to prevent air leaks.
6. Mode d'emploi
6.1 Powering On and Initial Pressure Build-up
- With batteries installed and accessories connected, ensure the pressure regulator knob (Figure 3) is turned fully counter-clockwise to the lowest setting.
- Flip the power switch to the 'ON' position. The compressor will begin to fill the 6L air tank.
- Monitor the tank pressure gauge. The compressor will automatically shut off once the maximum tank pressure (9.3 bar / 135 psi) is reached.
6.2 Réglage de la pression de sortie
- Once the tank is full, slowly turn the pressure regulator knob clockwise to increase the output pressure.
- Observe the output pressure gauge to set the desired working pressure for your tool or inflation task.
- Never exceed the recommended pressure for the item being inflated or the connected air tool.
6.3 Fonctionnement
- Engage your air tool or begin inflation. The compressor will cycle on and off automatically to maintain the set output pressure as air is consumed.
- When finished, turn the power switch to 'OFF'.
- Release any remaining pressure from the air hose and tool before disconnecting.
7. Entretien
Un entretien régulier garantit des performances optimales et prolonge la durée de vie de votre compresseur d'air.
- Tous les jours:
- Inspect the compressor for any visible damage, loose connections, or air leaks.
- Check the air filter (if accessible) for excessive dirt and clean if necessary.
- Weekly/After Each Use:
- Essuyez l'extérieur du compresseur avec un chiffon propre et sec.amp chiffon. N'utilisez pas de produits chimiques agressifs.
- Ensure the pressure relief valve (Figure 8) operates freely by pulling its ring briefly to release a small amount of air.
- Entretien de la batterie:
- Always store batteries in a cool, dry place away from direct sunlight.
- Chargez complètement les batteries avant de les entreposer et périodiquement pendant les longues périodes d'entreposage afin de préserver leur bon état.
8. Dépannage
| Problème | Cause possible | Solution |
|---|---|---|
| Le compresseur ne démarre pas | No batteries installed or batteries are discharged. Power switch is OFF. | Install charged batteries. Turn power switch to ON. |
| Sortie à basse pression d'air | Pressure regulator set too low. Air leak in hose or connections. Tank pressure too low. | Adjust regulator clockwise. Check and tighten all connections. Allow compressor to build tank pressure. |
| Le compresseur fonctionne en continu | Air leak in tank or connections. Pressure switch malfunction. | Check for leaks and tighten connections. If problem persists, seek professional service. |
| Bruit ou vibration excessif | Loose components. Compressor on uneven surface. | Check and tighten all fasteners. Place compressor on a stable, level surface. |
9. Spécifications
| Fonctionnalité | Spécification |
|---|---|
| Numéro de modèle | TACLI2003 |
| Voltage | 40V (2x20V) |
| Pression max. | 9.3 bars (135 psi) |
| Débit d'air | 98 L/min |
| Capacité du réservoir | 6 litres |
| Batteries compatibles | TOTAL 2.0Ah and 4.0Ah 20V Lithium-ion (not included) |
| Poids | 10.61 kg |
| Dimensions du produit | 40 x 30 x 30 cm |
| Type de source d'alimentation | Air Powered (Cordless) |
| Couleur | Turquoise |
10. Garantie et assistance
For warranty information, technical support, or service inquiries, please refer to the warranty card included with your purchase or contact your authorized TOTAL tools dealer. Keep your purchase receipt as proof of purchase for any warranty claims.