1. Introduction
This manual provides essential information for the safe and effective installation, operation, and maintenance of the JIAYIN JYPC-4 Series Electromagnetic Plunger Pump. This pump is designed for applications requiring precise water suction and delivery, commonly found in hot water dispensers and similar systems. Please read this manual thoroughly before using the product and retain it for future reference.
2. Produit terminéview
The JIAYIN JYPC-4 is a compact and efficient electromagnetic plunger pump. Key features include:
- Vol évaluétage: AC 100V - 120V, 60Hz, 22W
- Débit: 750 ±15% cc/min
- Pression de travail : ≥1.5 bar
- Milieu de travail : Water or non-corrosive liquids
- Matériel: Construction en plastique durable
- Mode de conduite : Électromagnétique

Figure 1 : Angulaire view of the JIAYIN JYPC-4 Series electromagnetic plunger pump, showing its compact design and main components.

Figure 2 : Gros plan view of the JIAYIN JYPC-4 pump, highlighting the electrical terminals and the product specification label.

Figure 3: Technical drawing providing detailed dimensions of the JIAYIN JYPC-4 pump in millimeters.
3. Spécifications techniques
| Paramètre | Valeur |
|---|---|
| Marque | JIAYIN |
| Modèle | JYPC-4 |
| Vol évaluétage | AC 100V - 120V, 60Hz |
| Consommation d'énergie | 22 W |
| Débit | 750 ±15% cc/min |
| Pression de travail | ≥1.5 bar |
| Type de pompe | Pompe à piston |
| Pump Shaft Position | Horizontal |
| Impeller Structure | Turbine fermée |
| Number of Impellers | S uniquetage |
| Poids net | 137 ±5g (approx. 4.8 oz) |
| Matériel | Plastique |
| Classe d'isolation | H |
| Mode de conduite | Électromagnétique |
| Méthode de connexion | Canule |
| Température ambiante | Ta 70℃ (158°F) |
| Température du fluide | Tf 60℃ (140°F) |
| Code UPC | 607469294553 |
4. Consignes de sécurité
Pour éviter toute blessure ou tout dommage, veuillez toujours respecter les consignes de sécurité suivantes :
- Sécurité électrique : Ensure the pump is connected to a power source matching the specified voltage (AC 100V-120V, 60Hz). Disconnect power before any installation, maintenance, or troubleshooting.
- Compatibilité fluide : Use only with water or non-corrosive liquids. Using corrosive fluids can damage the pump and void the warranty.
- Limites de température : Do not exceed the maximum ambient temperature of 70℃ (158°F) or fluid temperature of 60℃ (140°F).
- Installation correcte : Install the pump securely in a horizontal position as specified. Ensure all connections are tight to prevent leaks.
- Évitez le fonctionnement à sec : Do not operate the pump without fluid, as this can cause severe damage.
- Ventilation: Assurez une ventilation adéquate autour de la pompe pour éviter toute surchauffe.
- Enfants et animaux domestiques : Keep the pump and its components out of reach of children and pets.
5. Configuration et installation
Suivez ces étapes pour une installation correcte :
- Montage: Securely mount the pump in a horizontal position using appropriate fasteners. Refer to Figure 3 for dimensions and mounting points.
- Connexions fluides : Connect the inlet and outlet tubes to the pump's cannula ports. Ensure a tight fit to prevent leaks. For flow testing, a 13.8-inch silicon tube with an outer diameter of 0.31 inches and an inner diameter of 0.16 inches is recommended for the water inlet port.
- Connexion électrique : Connect the pump to a compatible AC 100V-120V, 60Hz power supply. Ensure wiring is done by a qualified professional if you are unsure.
- Amorçage (si nécessaire) : Depending on your system, you may need to prime the pump by ensuring the fluid path is filled with liquid before initial operation to prevent dry running.
6. Fonctionnement
Once installed and connected, operate the pump as follows:
- Mise sous tension : Apply power to the pump. The electromagnetic mechanism will activate, initiating the plunger action.
- Surveiller le flux : Observe the fluid flow to ensure it is within the specified range of 750 ±15% cc/min and that the working pressure is maintained at or above 1.5 bar.
- Fonctionnement continu : The pump is designed for continuous operation (ED100%).
- Éteindre: Disconnect power when the pump is not in use or when maintenance is required.
7. Entretien
Regular maintenance ensures optimal performance and extends the pump's lifespan:
- Nettoyage: Periodically inspect the pump for any external dirt or debris. Clean with a soft, damp chiffon. N'utilisez pas de produits chimiques agressifs.
- Relations: Regularly check all fluid and electrical connections for tightness and signs of wear or corrosion.
- Qualité du fluide : Ensure the working fluid remains clean and free of particles that could clog the pump. If the fluid contains impurities, consider adding a filter to the system.
- Stockage: If storing the pump for an extended period, ensure it is clean, dry, and stored in a cool, dry place away from direct sunlight and extreme temperatures.
8. Dépannage
Consultez le tableau ci-dessous pour connaître les problèmes courants et leurs solutions potentielles :
| Problème | Cause possible | Solution |
|---|---|---|
| La pompe ne démarre pas | Pas d'alimentation électrique Vol incorrecttage Connexion électrique lâche | Vérifiez la source d'alimentation Vérifier le voltage matches pump rating Connexions électriques sécurisées |
| Débit de fluide faible ou nul | Inlet/outlet clogged Air in the system (not primed) Leak in fluid connections Marche à sec | Inspect and clear blockages Amorcer la pompe Vérifier et serrer les connexions Ensure fluid supply is constant |
| Bruit inhabituel pendant le fonctionnement | Air dans le système Montage lâche Obstruction interne | Purger l'air du système Serrez les vis de montage Inspect for foreign objects (disconnect power first) |
| Fuites au niveau des connexions | Connexions desserrées Damaged tubing/cannula | Tighten all fluid connections Replace damaged tubing or cannula |
9. Garantie et assistance
For warranty information or technical support, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase. Any unauthorized disassembly or modification of the pump will void the warranty.