1. Introduction
This manual provides instructions for the safe and efficient operation and maintenance of your hOmeLabs Portable Air Scrubber. This heavy-duty air cleaner is designed for industrial and commercial use, featuring a 3-stage filtration system to improve air quality in various environments.
2. Consignes de sécurité
Please read all safety instructions before operating the unit to prevent injury or damage. Keep this manual for future reference.
- Veillez toujours à placer l'appareil sur une surface stable et plane.
- N'utilisez pas l'appareil avec un cordon d'alimentation ou une fiche endommagés.
- Keep the air intake and exhaust clear of obstructions.
- N'immergez pas l'appareil dans l'eau ou dans d'autres liquides.
- Unplug the unit before performing any maintenance or filter changes.
- This appliance is equipped with Auxiliary GFCI Outlets. Do not exceed the maximum amperage ratings for these outlets (12 Amps max with the unit OFF, 9 Amps max with the unit ON).
- The unit is ETL Listed and CARB Certified, indicating compliance with safety and air quality standards.

Image: ETL Listed and CARB Certified logos, indicating product compliance with safety and air quality standards.
3. Produit terminéview
The hOmeLabs Portable Air Scrubber is designed to capture airborne particles and odors using a multi-stage filtration system. Its robust construction and portable design make it suitable for various demanding environments.
Caractéristiques principales :
- 3-Stage Système de filtration : Includes a Pre-filter, Activated Carbon Filter, and HEPA Filter.
- Construction robuste : Rotomolded Polyethylene (LLDPE) housing for durability.
- Débit d'air élevé : Filters up to 750 sq. ft. with a maximum airflow of 500 CFM.
- Conception empilable : Can be stacked horizontally or vertically, allowing up to 3 units to be daisy-chained for a combined 1500 CFM.
- Portabilité: Equipped with a convenient handle and 360° swivel lockable casters for easy transport.
- Panneau de contrôle intégré : Features variable speed control, time and amps tracker, HEPA filter change reminder, resettable circuit breaker, and auxiliary GFCI outlets.

Image: The hOmeLabs Portable Air Scrubber, showcasing son design compact et robuste.

Image: A detailed diagram illustrating the three stages of filtration: Pre-filter for large particles, Carbon filter for odors, and HEPA filter for fine particles.
4. Installation
Follow these steps for initial setup of your air scrubber.
4.1 Déballage et inspection
- Carefully remove the air scrubber from its packaging.
- Vérifiez que l'appareil n'a pas subi de dommages pendant le transport. Si vous constatez des dommages, ne l'utilisez pas et contactez le service client.
- Ensure all filters are present and correctly installed. The unit comes with a complete set of filters.
- Remove the foam cap from the filter compartment before use.

Image: The unit includes a MERV-9 Pre-filter, Activated Carbon Filter, and HEPA Filter. It also shows the optional 14-inch inlet for ducting (ducting not included).
4.2 Placement
- Place the air scrubber in the desired location, ensuring adequate clearance around the air intake and exhaust vents.
- The unit can be used horizontally or vertically.
- For enhanced air purification in larger areas, multiple units can be daisy-chained and stacked. Up to 3 units can be connected, providing a combined airflow of 1500 CFM.

Image: Two air scrubbers are shown stacked, demonstrating the daisy-chain capability for increased air processing capacity.
4.3 Portabilité
- The unit features 360° swivel casters for easy movement. To lock the casters, press down on the lock plate on each wheel. To unlock, lift the lock plate.
- Use the integrated handle for single-handed relocation.

Image : Un gros plan view highlighting the lockable casters for stability and the ergonomic handle for easy transport.
5. Mode d'emploi
Familiarisez-vous avec le panneau de commande pour un fonctionnement efficace.
5.1 Fonctions du panneau de commande

Image: The control panel features a variable speed dial, a resettable circuit breaker, a HEPA filter change indicator, and auxiliary GFCI outlets.
- Cadran à vitesse variable : Turn the dial to adjust the fan speed from OFF to MAX.
- Disjoncteur: Resettable circuit breaker protects the unit from electrical overload. If the unit stops working, check and reset the breaker.
- Temps & Amps Tracker: Displays operational time and current amptirage au sort.
- HEPA Change Reminder: An indicator light will illuminate when it is time to inspect or change the HEPA filter.
- Auxiliary GFCI Outlets: Two 115V AC outlets are provided. Maximum load is 12 Amps when the air scrubber is OFF, and 9 Amps when the air scrubber is ON.
5.2 Démarrage de l'unité
- Branchez le cordon d’alimentation sur une prise électrique reliée à la terre.
- Turn the Variable Speed Dial from OFF to the desired speed setting.
- The unit will begin drawing air through its filtration system.
6. Entretien
Regular maintenance ensures optimal performance and extends the lifespan of your air scrubber.
6.1 Remplacement du filtre
The HEPA filter change reminder light indicates when the HEPA filter may need inspection or replacement. The pre-filter and carbon filter should also be checked regularly.
- Unplug the air scrubber from the power outlet.
- Repérez le panneau d'accès au filtre.
- Remove the old filters, starting with the pre-filter, then the carbon filter, and finally the HEPA filter. Dispose of used filters responsibly.
- Insert new filters in the reverse order: HEPA filter first, then the carbon filter, and finally the pre-filter. Ensure they are seated correctly.
- Fermez correctement le panneau d’accès au filtre.
- Plug the unit back in and resume operation.
6.2 Nettoyage de l'appareil
- Essuyez l'extérieur de l'unité avec de la publicitéamp chiffon. N'utilisez pas de nettoyants abrasifs ou de solvants.
- Veillez à ce qu'aucune eau ne pénètre dans le panneau de commande ou les composants électriques.
7. Dépannage
If you encounter issues with your air scrubber, refer to the following common problems and solutions.
| Problème | Cause possible | Solution |
|---|---|---|
| L'appareil ne s'allume pas | No power; Circuit breaker tripped; Power cord not fully plugged in | Check power outlet; Reset circuit breaker on control panel; Ensure power cord is securely plugged in. |
| Débit d'air réduit | Clogged filters; Obstruction at intake/exhaust | Inspect and replace filters as needed; Remove any obstructions. |
| Bruit inhabituel pendant le fonctionnement | Loose component; Obstruction in fan; Unit not on a level surface | Unplug and inspect for loose parts or obstructions; Ensure unit is on a stable, level surface. |
| HEPA Change Reminder light is on | HEPA filter needs inspection or replacement | Vérifiez et remplacez le filtre HEPA. |
8. Spécifications
| Fonctionnalité | Détail |
|---|---|
| Modèle | B096MS28PC |
| Dimensions du produit (P x L x H) | 16 x 22.6 x 25.5 pouces |
| Poids de l'article | 47 livres |
| Source d'énergie | CA/CC |
| Méthode de contrôle | Button Control / Touch (Dial) |
| Type de filtre | Pre-Filter, Activated Carbon Filter, HEPA Filter |
| Couverture de la surface au sol | Jusqu'à 750 XNUMX pieds carrés |
| Débit d'air maximal | 500 CFM (1500 CFM when daisy-chained with 3 units) |
| Niveau de bruit | 65 décibels |
| Capacité de filtration des contaminants | Cigarette smoke, dust, odors |
| Ducting Compatibility | 14 inch (optional, not included) |
| Code UPC | 810049720544 |
| Couleur | Gris |

Image: The air scrubber's dimensions are 22.5 inches high, 22.6 inches wide, and 16 inches deep, with a weight of 47 lbs. It also shows a 25 ft power cord.
9. Garantie et assistance
For warranty information or technical support, please refer to the hOmeLabs official webou contactez directement leur service client. Conservez votre reçu d'achat pour toute réclamation sous garantie.
Pour plus d'informations ou pour acheter des filtres de remplacement, veuillez consulter le site web. Boutique homeLabs.