Total TWP47506

Total TWP47506 750W Automatic Jet Water Pump User Manual

Model: TWP47506

1. Produit terminéview

The Total TWP47506 750W Automatic Jet Water Pump is designed for efficient clean water collection and distribution. It is suitable for drawing water from wells, boreholes, open tanks, and other water supply sources. Primary applications include watering vegetable gardens, personal plots, and ensuring water circulation in fountains and various water features. Its design prioritizes ease of maintenance and portability, featuring an external tank location. The pump incorporates a brushless induction motor for long-lasting, maintenance-free operation. The robust cast iron pump casing can be rotated 90 degrees for flexible installation. This pump is capable of integration into automated water supply systems.

Total TWP47506 750W Automatic Jet Water Pump

Figure 1 : Total TWP47506 750W Automatic Jet Water Pump. This image shows the complete pump unit with its motor and casing.

2. Consignes de sécurité

Read all safety warnings and instructions carefully before operating this product. Failure to follow these instructions may result in electric shock, fire, and/or serious injury.

Sécurité générale

  • Portez toujours un équipement de protection individuelle (EPI) approprié tel que des lunettes de sécurité et des gants.
  • Veillez à placer la pompe sur une surface stable et plane afin d'éviter tout basculement.
  • Tenir les enfants et les personnes non autorisées à l'écart de la zone d'opération.
  • Ne pas utiliser la pompe dans des atmosphères explosives, telles qu'en présence de liquides, de gaz ou de poussières inflammables.
  • Never use the pump to transfer flammable, corrosive, or explosive liquids.
  • Disconnect the power supply before performing any maintenance, cleaning, or when the pump is not in use.

Sécurité électrique

  • Assurer l'alimentation voltage matches the specifications on the pump's rating label (220-240V, 50Hz).
  • Use a properly grounded outlet. Do not modify the plug.
  • Do not expose the pump or electrical connections to rain or wet conditions.
  • Avoid using extension cords unless absolutely necessary. If an extension cord is used, ensure it is rated for outdoor use and has the correct gauge for the pump's power requirements.
  • Never carry the pump by its power cord.
  • Regularly inspect the power cord for damage. If damaged, have it replaced by a qualified electrician.

3. Contenu du colis

Vérifiez que tous les éléments énumérés ci-dessous sont présents et non endommagés lors du déballage :

  • 1 x Total TWP47506 750W Automatic Jet Water Pump
  • 1 x pressostat
  • 1 x Stainless Steel Hose
  • 1 manomètre
  • 1 x Three-way Brass Fitting
  • Manuel de l'utilisateur (ce document)

4. Spécifications techniques

Spécification Valeur
Numéro de modèle TWP47506
Taper Self-priming Automatic Jet Pump
Puissance nominale 750W (1.0CV)
Voltage 220-240V
Fréquence 50 Hz
Tête max 45 mètres
Débit maximal 60 litres/minute
Max aspiration 9 mètres
Diamètre du tuyau 1 x 1 pouces
Type de moteur Copper Wire Induction Motor (Brushless)
Matériau de la roue Acier inoxydable
Pompe Casing Matériau Fonte
Longueur du câble 0.3 mètres
Tank Capacity (Cylindrical) 24 litres
Dimensions du produit (L x l x H) 30 x 19 x 22 cm
Poids de l'article 1.5 kg
Couleur Argent

5. Configuration et installation

5.1 Placement

  • Position the pump on a firm, level, and dry surface.
  • Assurez une ventilation adéquate autour de la pompe pour éviter toute surchauffe.
  • Protect the pump from direct exposure to weather elements (rain, direct sunlight, frost).
  • Keep the pump as close as possible to the water source to minimize suction lift and maximize efficiency.

5.2 Raccordement des tuyaux

The pump is equipped with standard inch fittings for both suction and discharge pipes.

  • Tuyau d'aspiration: Connect a rigid, airtight suction pipe (1 inch diameter) to the pump's inlet. Ensure all connections are sealed to prevent air leaks, which can affect priming and pump performance. A foot valve with a strainer should be installed at the end of the suction pipe submerged in the water source to prevent debris from entering the pump and to maintain prime.
  • Tuyau de décharge : Connect a discharge pipe (1 inch diameter) to the pump's outlet. Use the provided three-way brass fitting, pressure switch, and pressure gauge as part of your water supply system. Ensure all connections are secure.

5.3 Amorçage de la pompe

This is a self-priming pump, but initial priming is crucial for proper operation. Before first use or after the pump has run dry:

  1. Assurez-vous que le tuyau d'aspiration soit entièrement immergé dans la source d'eau.
  2. Locate the priming plug on the top of the pump casing.
  3. Unscrew the priming plug and slowly fill the pump casing with clean water until it overflows.
  4. Replace and securely tighten the priming plug.
  5. Open any valves on the discharge side to allow air to escape during startup.

5.4 Connexion électrique

  • Connect the pump's power cord to a grounded electrical outlet (220-240V, 50Hz).
  • Ensure the electrical circuit is protected by a Residual Current Device (RCD) for added safety.

6. Fonctionnement

6.1 Démarrage de la pompe

  1. Ensure the pump has been properly primed (Section 5.3).
  2. Verify all pipe connections are secure and leak-free.
  3. Plug the pump into the power outlet. The pump will start automatically if connected to an automated system with a pressure switch.
  4. Observe the pressure gauge. The pressure should rise as the pump builds pressure.
  5. If the pump does not draw water within a few minutes, switch it off, re-prime, and check for air leaks in the suction line.

6.2 Fonctionnement automatique

When integrated into a water supply system with the included pressure switch, the pump will automatically start when water pressure drops (e.g., when a tap is opened) and stop when the desired pressure is reached (e.g., when the tap is closed). The 24-liter cylindrical tank helps maintain consistent pressure and reduces pump cycling.

6.3 Arrêt de la pompe

For temporary shutdown, close all water outlets. The pump will stop automatically if operating in an automated system. For complete shutdown or extended periods of non-use, unplug the pump from the power supply.

7. Entretien

Regular maintenance ensures optimal performance and extends the lifespan of your pump. Always disconnect the power supply before performing any maintenance.

7.1 Contrôles réguliers

  • Inspectez le cordon d’alimentation et la fiche pour déceler tout signe de dommage.
  • Check all pipe connections for leaks. Tighten if necessary.
  • Ensure the foot valve strainer is clear of debris. Clean if clogged.
  • Soyez attentif aux bruits inhabituels pendant le fonctionnement, car ils peuvent indiquer un problème.

7.2 Nettoyage

Essuyez l'extérieur de la pompe avec de la publicitéamp cloth. Do not use harsh chemicals or abrasive cleaners. Ensure the motor's ventilation openings are free from dust and debris.

7.3 Hivernage (pour les climats froids)

If the pump is exposed to freezing temperatures, it must be drained to prevent damage:

  1. Débrancher l'alimentation électrique.
  2. Drain all water from the pump casing by unscrewing the drain plug (if present) or by tilting the pump.
  3. Disconnect the suction and discharge pipes and drain them completely.
  4. Rangez la pompe dans un endroit sec et à l'abri du gel.

8. Dépannage

Avant de contacter le service client, veuillez consulter le tableau suivant pour connaître les problèmes courants et leurs solutions.

Problème Cause possible Solution
La pompe ne démarre pas Pas d'alimentation électrique
Cordon d'alimentation/prise défectueux
Protection contre les surcharges du moteur déclenchée
Vérifiez la connexion électrique et la prise
Inspecter et remplacer si endommagé
Allow motor to cool, then restart. Check for blockages.
La pompe fonctionne mais l'eau n'est pas distribuée. Pompe non amorcée
Fuite d'air dans la conduite d'aspiration
Hauteur d'aspiration trop élevée
Foot valve clogged or stuck
Source d'eau vide
Re-prime the pump (Section 5.3)
Check all suction connections for leaks and tighten
Relocate pump closer to water source
Clean or replace foot valve
Ensure adequate water in source
Débit ou pression faibles Partial blockage in pipes/impeller
Fuite d'air dans la conduite d'aspiration
Roue usée
Incorrect pressure switch setting
Inspect and clear blockages
Check and seal suction connections
Contactez un personnel de service qualifié
Adjust pressure switch according to manufacturer guidelines (if adjustable)
La pompe s'allume et s'éteint fréquemment. Leak in discharge system
Pressure tank pre-charge incorrect
Pressostat défectueux
Check for leaks in pipes, fittings, or fixtures
Check and adjust pressure tank air pre-charge
Inspect and replace pressure switch if necessary

9. Garantie et assistance

This Total TWP47506 750W Automatic Jet Water Pump comes with a standard manufacturer's warranty. Please refer to the warranty card included with your purchase for specific terms and conditions, including warranty period and coverage details.

For technical assistance, spare parts, or warranty claims, please contact Total customer support through your retailer or visit the official Total website for contact information in your region. When contacting support, please have your model number (TWP47506) and purchase date available.

© 2023 Total Inc. All rights reserved. Information in this manual is subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.