1. Introduction
The VTSYIQI VTS-160A Water Activity Meter is designed to measure the water activity of various food products. Water activity is a critical factor influencing food stability, microbial growth, and chemical, enzymatic, and physical changes that affect food quality and shelf life. This portable device provides accurate measurements to assist in food preservation and quality control.
Caractéristiques principales :
- Portable and lightweight design (approx. 100g).
- High precision with an accuracy of ±0.02 aw.
- Fast measurement time, typically 5 minutes.
- Integrated sensors and readings for ease of use.
- LCD backlight digital display showing water activity and temperature simultaneously.
- Automatic and manual shutdown functions.
- Sous-voltage alarm indication.
- USB data output option for PC connection.

Figure 1.1: The VTS-160A Water Activity Meter in use, demonstrating its application across various food types.

Figure 1.2: Product Introduction diagram highlighting the main components of the VTS-160A meter.
2. Composants et accessoires
The VTS-160A Water Activity Meter comes with the following standard accessories:
- Main Unit (VTS-160A Water Activity Meter)
- Sample Plate(s)
- Mallette de transport
- Manuel d'utilisation

Figure 2.1: The VTS-160A Water Activity Meter with its standard accessories, including the carrying case and sample plates.
3. Spécifications
Paramètres techniques :
| Paramètre | Valeur |
|---|---|
| Afficher | 6-bit backlight LCD digital display (3-bit humidity aw, 3-bit temperature) |
| Gamme | 0 to 1.0 aw |
| Résolution | ±0.01 aw |
| Précision | ±0.02 aw |
| Capteur | Capteur d'humidité non conducteur |
| Sample temps | 5 minutes (en moyenne) |
| Operating Condition (Temperature) | 0 à 50°C (32 à 122°F) |
| Operating Condition (Humidity) | <95% HR (sans condensation) |
| Alimentation électrique | 2 x 1.5V AAA (UM-4) Batteries (not included) |
| Dimensions | 135 x 70 x 44 mm |
| Poids | 100g (sans batteries) |
Spécifications générales :
- Product Dimensions: 40 x 10 x 25 cm (packaged)
- Item Weight: 4 kg (packaged)
- Couleur: Gris
4. Installation
4.1 Installation de la batterie
- Repérez le compartiment à piles à l'arrière de l'appareil.
- Faites glisser le couvercle de la batterie pour l'ouvrir.
- Insert two 1.5V AAA (UM-4) batteries, ensuring correct polarity.
- Fermez soigneusement le couvercle de la batterie.

Figure 4.1: Open battery compartment on the back of the VTS-160A meter.
5. Procédure d'exploitation
5.1 Measuring Water Activity
- Appuyez sur le Pouvoir key to switch on the meter. The gauge will enter auto mode, automatically initiating the water activity test.
- Placez votre sample dans un espace propreample plate. Ensure the sample is representative and fills the plate adequately without overflowing.
- Carefully cover the sensor of the meter onto the sample plate, ensuring a good seal.
- Allow approximately 5 minutes for the reading to stabilize. Once stable, the water activity value will be displayed on the LCD.
- After testing, press and hold the Pouvoir key for approximately 3 seconds to turn off the meter.
- Nettoyer le sample plate thoroughly after each use to prevent cross-contamination and ensure accurate future readings.

Figure 5.1: Step-by-step guide for performing a water activity measurement.
6. Reading Correction (Calibration)
If it becomes necessary to correct the reading value, follow these steps:
- Appuyez et maintenez enfoncé le Pouvoir touche pendant environ 7 secondes.
- Release the key when the signal 'Cor' appears on the display. A decimal number with two places, representing the current correction value, will be shown.
- Open the battery cover on the back of the meter. Below the battery slot, you will find two small holes.
- Using a small, hard, non-conductive tool (e.g., a small screwdriver or toothpick), gently touch the key inside the left hole to increase the correction value.
- Gently touch the key inside the right hole to decrease the correction value. Adjust the value as needed.
- Appuyez sur le Pouvoir key again to confirm the new correction value. The measured reading will update, and the calibration is complete.

Figure 6.1: Step-by-step guide for performing reading correction.
7. Entretien
7.1 Nettoyage
- Nettoyez toujours les sample plate immediately after each use to prevent residue buildup, which can affect measurement accuracy.
- Utilisez un chiffon doux et sec.amp cloth to wipe the exterior of the meter. Do not use abrasive cleaners or solvents.
- Ensure no liquids enter the sensor area or battery compartment.
7.2 Stockage
- When not in use, store the meter in its carrying case to protect it from dust and physical damage.
- Conserver dans un endroit frais et sec, à l'abri de la lumière directe du soleil et des températures extrêmes.
- Retirez les piles si l'appareil ne doit pas être utilisé pendant une période prolongée afin d'éviter toute fuite.
8. Dépannage
If you encounter issues with your VTS-160A Water Activity Meter, consider the following:
- Pas d'alimentation : Vérifiez que les piles sont correctement installées et suffisamment chargées. Remplacez-les si nécessaire.
- Lectures inexactes : Assurez-vous que le sample plate is clean and the sensor is properly seated on the sample. Perform a reading correction as described in Section 6. Verify that the operating conditions (temperature, humidity) are within the specified range.
- Lectures lentes : Assurez-vous que le sample is properly prepared and the environment is stable.
- Problèmes d'affichage : Si l'écran est faiblement lumineux ou clignote, remplacez les piles.
Pour les problèmes persistants non résolus par ces étapes, veuillez contacter le service client.
9. Informations d'assistance
For technical assistance, warranty inquiries, or service, please contact VTSYIQI customer support through your purchase platform or the official VTSYIQI website.
Please have your model number (VTS-160A) and purchase date available when contacting support.