VTSYIQI VTS-160A

VTSYIQI VTS-160A Water Activity Meter Instruction Manual

Model: VTS-160A

1. Introduction

The VTSYIQI VTS-160A Water Activity Meter is designed to measure the water activity of various food products. Water activity is a critical factor influencing food stability, microbial growth, and chemical, enzymatic, and physical changes that affect food quality and shelf life. This portable device provides accurate measurements to assist in food preservation and quality control.

Caractéristiques principales :

  • Portable and lightweight design (approx. 100g).
  • High precision with an accuracy of ±0.02 aw.
  • Fast measurement time, typically 5 minutes.
  • Integrated sensors and readings for ease of use.
  • LCD backlight digital display showing water activity and temperature simultaneously.
  • Automatic and manual shutdown functions.
  • Sous-voltage alarm indication.
  • USB data output option for PC connection.
VTSYIQI VTS-160A Water Activity Meter displaying 0.63 aw, surrounded by various food items like fruits, vegetables, and drinks.

Figure 1.1: The VTS-160A Water Activity Meter in use, demonstrating its application across various food types.

Diagram illustrating the VTS-160A Water Activity Meter's components: Display, Water Activity Value, Temperature Value, Battery Cover, Power Key, and Sensor.

Figure 1.2: Product Introduction diagram highlighting the main components of the VTS-160A meter.

2. Composants et accessoires

The VTS-160A Water Activity Meter comes with the following standard accessories:

  • Main Unit (VTS-160A Water Activity Meter)
  • Sample Plate(s)
  • Mallette de transport
  • Manuel d'utilisation
The VTS-160A Water Activity Meter, its blue carrying case, sample plates, and instruction manual.

Figure 2.1: The VTS-160A Water Activity Meter with its standard accessories, including the carrying case and sample plates.

3. Spécifications

Paramètres techniques :

ParamètreValeur
Afficher6-bit backlight LCD digital display (3-bit humidity aw, 3-bit temperature)
Gamme0 to 1.0 aw
Résolution±0.01 aw
Précision±0.02 aw
CapteurCapteur d'humidité non conducteur
Sample temps5 minutes (en moyenne)
Operating Condition (Temperature)0 à 50°C (32 à 122°F)
Operating Condition (Humidity)<95% HR (sans condensation)
Alimentation électrique2 x 1.5V AAA (UM-4) Batteries (not included)
Dimensions135 x 70 x 44 mm
Poids100g (sans batteries)

Spécifications générales :

  • Product Dimensions: 40 x 10 x 25 cm (packaged)
  • Item Weight: 4 kg (packaged)
  • Couleur: Gris

4. Installation

4.1 Installation de la batterie

  1. Repérez le compartiment à piles à l'arrière de l'appareil.
  2. Faites glisser le couvercle de la batterie pour l'ouvrir.
  3. Insert two 1.5V AAA (UM-4) batteries, ensuring correct polarity.
  4. Fermez soigneusement le couvercle de la batterie.
The back of the VTS-160A Water Activity Meter with the battery compartment open, showing where to insert AAA batteries.

Figure 4.1: Open battery compartment on the back of the VTS-160A meter.

5. Procédure d'exploitation

5.1 Measuring Water Activity

  1. Appuyez sur le Pouvoir key to switch on the meter. The gauge will enter auto mode, automatically initiating the water activity test.
  2. Placez votre sample dans un espace propreample plate. Ensure the sample is representative and fills the plate adequately without overflowing.
  3. Carefully cover the sensor of the meter onto the sample plate, ensuring a good seal.
  4. Allow approximately 5 minutes for the reading to stabilize. Once stable, the water activity value will be displayed on the LCD.
  5. After testing, press and hold the Pouvoir key for approximately 3 seconds to turn off the meter.
  6. Nettoyer le sample plate thoroughly after each use to prevent cross-contamination and ensure accurate future readings.
Six-step diagram illustrating the measuring procedure: 1. Press Power Key, 2. Place sample, 3. Cover sensor, 4. Wait for stable reading, 5. Record reading, 6. Power off.

Figure 5.1: Step-by-step guide for performing a water activity measurement.

6. Reading Correction (Calibration)

If it becomes necessary to correct the reading value, follow these steps:

  1. Appuyez et maintenez enfoncé le Pouvoir touche pendant environ 7 secondes.
  2. Release the key when the signal 'Cor' appears on the display. A decimal number with two places, representing the current correction value, will be shown.
  3. Open the battery cover on the back of the meter. Below the battery slot, you will find two small holes.
  4. Using a small, hard, non-conductive tool (e.g., a small screwdriver or toothpick), gently touch the key inside the left hole to increase the correction value.
  5. Gently touch the key inside the right hole to decrease the correction value. Adjust the value as needed.
  6. Appuyez sur le Pouvoir key again to confirm the new correction value. The measured reading will update, and the calibration is complete.
Six-step diagram illustrating the reading correction procedure: 1. Press Power Key, 2. Place meter on standard cell, 3. Observe reading, 4. Press and hold Power Key for 'Cor' display, 5. Adjust correction value using holes, 6. Press Power Key to complete calibration.

Figure 6.1: Step-by-step guide for performing reading correction.

7. Entretien

7.1 Nettoyage

  • Nettoyez toujours les sample plate immediately after each use to prevent residue buildup, which can affect measurement accuracy.
  • Utilisez un chiffon doux et sec.amp cloth to wipe the exterior of the meter. Do not use abrasive cleaners or solvents.
  • Ensure no liquids enter the sensor area or battery compartment.

7.2 Stockage

  • When not in use, store the meter in its carrying case to protect it from dust and physical damage.
  • Conserver dans un endroit frais et sec, à l'abri de la lumière directe du soleil et des températures extrêmes.
  • Retirez les piles si l'appareil ne doit pas être utilisé pendant une période prolongée afin d'éviter toute fuite.

8. Dépannage

If you encounter issues with your VTS-160A Water Activity Meter, consider the following:

  • Pas d'alimentation : Vérifiez que les piles sont correctement installées et suffisamment chargées. Remplacez-les si nécessaire.
  • Lectures inexactes : Assurez-vous que le sample plate is clean and the sensor is properly seated on the sample. Perform a reading correction as described in Section 6. Verify that the operating conditions (temperature, humidity) are within the specified range.
  • Lectures lentes : Assurez-vous que le sample is properly prepared and the environment is stable.
  • Problèmes d'affichage : Si l'écran est faiblement lumineux ou clignote, remplacez les piles.

Pour les problèmes persistants non résolus par ces étapes, veuillez contacter le service client.

9. Informations d'assistance

For technical assistance, warranty inquiries, or service, please contact VTSYIQI customer support through your purchase platform or the official VTSYIQI website.

Please have your model number (VTS-160A) and purchase date available when contacting support.

Documents connexes - VTS-160A

Préview Guide d'utilisation du compteur d'activité de l'eau
Instructions étape par étape pour l'utilisation d'un compteur d'activité de l'eau VTSYIQI, y compris samples procédures de préparation et de mesure pour les tests alimentaires.
Préview Guide d'étalonnage et données d'humidité relative pour les compteurs d'activité de l'eau VTSYIQI
Procédure d'étalonnage détaillée pour les compteurs d'activité de l'eau utilisant des solutions salines saturées, incluant des tableaux complets de données d'humidité relative à différentes températures pour plusieurs sels. Référence essentielle pour les produits de HeFei Vetus Electronic Technology Co., Ltd.
Préview Compteur d'activité de l'eau VTSYIQI : guide d'utilisation et bonnes pratiques de mesure
Ce guide fournit les instructions essentielles pour l'utilisation de l'appareil de mesure de l'activité de l'eau VTSYIQI, notamment les modèles VTS-160A et WA-18CA. Apprenez-en davantage sur le positionnement correct de la cassette, la garantie d'un environnement de mesure étanche et l'interprétation des résultats pour des tests précis de l'activité de l'eau dans les produits alimentaires.
Préview Manuel d'utilisation et instructions de fonctionnement du compteur d'activité aquatique intelligent HD-6
Manuel d'utilisation complet du capteur d'activité de l'eau intelligent HD-6 de VTSYAQI. Ce manuel couvre les spécifications techniques, l'installation, le fonctionnement, l'étalonnage, la configuration du logiciel, le dépannage et les informations importantes pour une mesure précise de l'activité de l'eau.
Préview Prestige Skirting and Dado Trunking System Technical Data Sheet
Technical data sheet and installation guide for the MK Prestige Skirting and Dado Trunking System. Includes specifications, dimensions, and installation instructions.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.