1. Introduction
This manual provides essential information for the safe and efficient use of your Takagi T-H3-DV-P Indoor Tankless High Efficiency Condensing Water Heater (LP). Please read all instructions carefully before installation or operation to ensure proper function and to prevent property damage or personal injury. Keep this manual for future reference.

Figure 1 : Face avant view of the Takagi T-H3-DV-P Indoor Tankless Water Heater. This image shows the compact design, the Takagi logo, and the integrated control panel at the bottom.
2. Consignes de sécurité
Important: Failure to follow these safety instructions could result in fire, explosion, electric shock, property damage, personal injury, or death. Installation and service must be performed by a qualified installer, service agency, or gas supplier.
- Assurez une ventilation adéquate conformément aux instructions d'installation.
- Ne stockez pas et n’utilisez pas d’essence ou d’autres vapeurs et liquides inflammables à proximité de cet appareil ou de tout autre appareil.
- Si vous sentez une odeur de gaz :
- N'essayez pas d'allumer un appareil.
- Ne touchez aucun interrupteur électrique ; n’utilisez aucun téléphone dans votre immeuble.
- Appelez immédiatement votre fournisseur de gaz depuis le téléphone d'un voisin. Suivez les instructions du fournisseur de gaz.
- Si vous ne parvenez pas à joindre votre fournisseur de gaz, appelez les pompiers.
- Cet appareil est destiné à un usage intérieur uniquement.
- Débranchez toujours l'alimentation avant de réparer l'appareil.
3. caractéristiques du produit
The Takagi T-H3-DV-P is an advanced tankless water heater designed for high efficiency and durability. Key features include:
- Ultra-Low NOx Condensing Technology: Provides significant energy cost savings and meets stringent emission standards.
- Haute efficacité : ENERGY STAR qualified with a 0.93 energy factor.
- Durable Heat Exchangers: Features a commercial-grade HRS35 copper primary heat exchanger and a Type 316L stainless steel secondary heat exchanger for extended lifespan.
- Allumage électronique : Eliminates the need for a pilot light, enhancing safety and efficiency.
- Built-in Temperature Controller and Diagnostics: Allows for precise temperature setting and easy troubleshooting.
- Internal Freeze Protection System: Protects the unit in cold environments.
- Power Direct Vent Design: Offers flexible venting options using PVC, CPVC, or ABS piping.
- Multi-Link Capability: Can be easy-linked up to 4 units without additional parts, and multi-linked up to 20 units for larger commercial applications.
- LP Gas Compatibility: Designed for use with Liquid Propane (LP) gas.
4. Configuration et installation
Installation of the T-H3-DV-P unit must be performed by a qualified professional in accordance with all local and national codes and regulations. This section provides a general overview; refer to the detailed installation guide provided with the product for complete instructions.
4.1 Liste de contrôle de pré-installation
- Verify that the unit is the correct model (T-H3-DV-P) and fuel type (LP) for your application.
- Ensure adequate clearance around the unit for service and ventilation.
- Confirm availability of appropriate gas supply, water supply, and electrical connections.
- Prepare venting materials (PVC, CPVC, or ABS) according to local codes and manufacturer specifications.
4.2 Montage de l'unité
The T-H3-DV-P is designed for wall or ceiling mounting. Use appropriate mounting hardware capable of supporting the unit's weight (approximately 62 pounds) when filled with water. Ensure the mounting surface is structurally sound.
4.3 Connexions de plomberie
- Connect cold water inlet and hot water outlet lines.
- Install isolation valves and a pressure relief valve as required by code.
- Flush the water lines thoroughly before connecting to the unit to remove debris.
4.4 Raccordements au gaz
Connect the LP gas supply line to the unit's gas inlet. Ensure all gas connections are properly sealed and tested for leaks using a non-corrosive leak detection solution.
4.5 Connexions électriques
The indoor model includes a factory-installed power cord. Connect the unit to a properly grounded electrical outlet as per local electrical codes. Verify the correct voltaget ampexigences moyennes.
4.6 Ventilation
Install the power direct vent system using approved PVC, CPVC, or ABS materials. Follow the manufacturer's guidelines for vent pipe sizing, length, and termination to ensure proper combustion and exhaust.
5. Mode d'emploi
Once installed and all connections are verified, the T-H3-DV-P is ready for operation. The unit features a built-in temperature controller for user adjustments.
5.1 Démarrage initial
- Ensure all water and gas supply valves are open.
- Open a hot water faucet in your home to allow water to flow through the unit. This purges air from the system.
- Plug in the power cord or turn on the electrical supply to the unit.
- The unit will perform a self-diagnostic check and then ignite to heat the water.
- Close the hot water faucet once hot water is consistently flowing.
5.2 Réglage de la température de l'eau
Use the control panel on the front of the unit to adjust the desired hot water temperature. Refer to the display for current settings and error codes.
- Appuyez sur le UP or VERS LE BAS arrows to increase or decrease the temperature.
- L'écran affichera la température réglée.
- Allow a few moments for the unit to adjust to the new setting.
5.3 Fonctionnement normal
The unit will automatically activate when a hot water faucet is opened and deactivate when it is closed. The flow rate and incoming water temperature will influence the maximum achievable hot water temperature.
6. Entretien
Regular maintenance ensures optimal performance and longevity of your tankless water heater. It is recommended that a qualified service technician perform annual maintenance.
6.1 Descaling the Heat Exchanger
Mineral deposits (scale) can build up in the heat exchanger, reducing efficiency. Descaling should be performed annually or more frequently in areas with hard water.
- Turn off the power and close the gas and water supply valves to the unit.
- Connect a descaling pump and hoses to the service valves (if installed).
- Circulate an approved descaling solution through the unit for the recommended duration.
- Flush the unit thoroughly with fresh water after descaling.
- Restore water, gas, and power supplies.
6.2 Inspecting the Vent System
Periodically inspect the vent pipes for any obstructions, leaks, or damage. Ensure all connections are secure.
6.3 Nettoyage du filtre d'arrivée d'eau
The water inlet filter should be checked and cleaned periodically to prevent debris from entering the unit.
- Turn off power and water supply.
- Locate and remove the water inlet filter.
- Rinse the filter under running water to remove any sediment.
- Reinstall the filter and restore water and power.
7. Dépannage
Cette section propose des solutions aux problèmes courants. Pour les problèmes complexes ou si un code d'erreur persiste, veuillez contacter un technicien qualifié.
| Problème | Cause possible | Solution |
|---|---|---|
| Pas d'eau chaude / L'appareil ne s'allume pas |
|
|
| Inconsistent hot water temperature |
|
|
| Code d'erreur affiché | Dysfonctionnement spécifique du système | Refer to the detailed error code list in the full installation manual or contact customer support. |
8. Spécifications
Technical specifications for the Takagi T-H3-DV-P Indoor Tankless Water Heater:
- Modèle: T-H3-DV-P
- Type de carburant : Propane liquide (LP)
- Type de montage : Mur ou plafond
- Efficacité: 0.93 Energy Factor (ENERGY STAR Qualified)
- Débit maximum: 10.0 gallons par minute (GPM)
- Échangeur de chaleur: HRS35 Commercial-Grade Copper (Primary), Type 316L Stainless Steel (Secondary)
- Allumage: Électronique
- Émissions de NOx : Ultra-Low NOx Condensing Technology
- Type d'évent : Power Direct Vent (PVC, CPVC, ABS)
- Poids: Environ 62 livres
- Dimensions: Dimensions approximatives de l'emballage : 34 x 23 x 11 pouces.
- Caractéristiques spéciales : Internal Freeze Protection System, Built-in Temperature Controller and Diagnostics, Easy-Link up to 4 units, Multi-Link up to 20 units.
9. Garantie et assistance
For detailed warranty information, please refer to the warranty card included with your product or visit the official Takagi webConsultez le site. Conservez votre preuve d'achat pour toute réclamation au titre de la garantie.
For technical support, service, or to locate an authorized service provider, please contact Takagi customer service. Contact information can typically be found on the manufacturer's website ou dans l'emballage du produit.