Astralpool Aster 99- Ø 500

Astralpool Aster 99- Sand Filter with Valve (Ø 500) - Instruction Manual

Model: Aster 99- Ø 500

1. Produit terminéview

The Astralpool Aster 99- Sand Filter is a high-performance filtration system designed for swimming pools. Constructed from laminated polyester and fiberglass, this filter ensures durability and efficient water purification. It features a lateral selector valve, a manometer for pressure monitoring, and a drain valve for easy water emptying. This manual provides essential information for the safe and effective installation, operation, and maintenance of your filter.

  • Construction: Laminated polyester and fiberglass for enhanced durability.
  • Composants: Equipped with a manometer, drain valve, and lateral selector valve.
  • Pression de service maximale: 2.5 kg/cm².
  • Maximum Filtration Capacity: 50 m³/h/m².

2. Configuration et installation

Proper installation is crucial for the optimal performance and longevity of your Astralpool Aster 99- Sand Filter. Ensure all connections are secure and watertight.

2.1. Sélection du site

Choose a level, solid surface for the filter, preferably close to the pool pump and the pool itself. The location should be protected from direct sunlight and adverse weather conditions, and allow sufficient space for maintenance and operation.

2.2. Assemblage du filtre

  1. Positionnez le filtre : Place the filter tank on its designated base.
  2. Ajouter un média filtrant : Carefully fill the filter tank with the appropriate amount and type of filter sand (or other media) as recommended by Astralpool. Ensure the central pipe is protected during this process to prevent sand from entering it.
  3. Installation de la vanne multivoies : Attach the lateral selector valve to the top of the filter tank. Ensure the O-ring is correctly seated and the clamp est solidement fixé.
  4. Connecter la plomberie : Connect the pump outlet to the "PUMP" port on the valve, the pool return line to the "RETURN" port, and the waste line to the "WASTE" port. Use appropriate fittings and sealants to prevent leaks.
  5. Installation du manomètre : Screw the manometer into its designated port on the multi-port valve.
  6. Vanne de vidange: Ensure the drain valve at the bottom of the filter is closed.
Technical drawing of Astralpool Aster 99- Sand Filter with dimensions

Figure 1 : Technical drawing of the Astralpool Aster 99- Sand Filter, illustrating key dimensions (D, H, M, N, K) and overall structure. This diagram helps in understanding the physical layout and connection points of the filter.

3. Mode d'emploi

The multi-port valve controls the filter's operation. Always turn off the pump before changing the valve position to prevent damage.

3.1. Valve Positions

  • FILTRE: Normal filtration mode. Water flows through the filter media and returns to the pool.
  • REMOUS: Cleans the filter media by reversing water flow. Water is discharged through the waste line.
  • RINCER: Used after backwashing to settle the filter media and flush out any remaining debris from the waste line.
  • ÉGOUTS/DRAINAGE : Bypasses the filter, sending water directly to the waste line. Useful for vacuuming heavy debris or lowering pool water level.
  • RECIRCULER : Bypasses the filter, circulating water directly back to the pool. Useful for chemical distribution without filtration.
  • FERMÉ: Shuts off all flow to the filter and pool. Use for pump maintenance or when the filter is not in use.

3.2. Démarrage initial

  1. Ensure the filter is filled with sand and all connections are secure.
  2. Set the multi-port valve to the "BACKWASH" position.
  3. Turn on the pump and backwash for 2-3 minutes, or until the water in the sight glass (if present) runs clear.
  4. Éteignez la pompe.
  5. Set the valve to the "RINSE" position.
  6. Mettez la pompe en marche et rincez pendant 30 à 60 secondes.
  7. Éteignez la pompe.
  8. Set the valve to the "FILTER" position.
  9. Turn on the pump. The filter is now operating in normal filtration mode.

4. Entretien

Regular maintenance ensures efficient filtration and extends the life of your Astralpool Aster 99- Sand Filter.

4.1. Backwashing

Backwash the filter when the pressure gauge reading is 0.2-0.3 kg/cm² (3-5 psi) above the clean filter's starting pressure, or when pool water clarity decreases.

  1. Éteignez la pompe.
  2. Réglez la vanne multivoies sur « RÉTROLAVAGE ».
  3. Turn on the pump and backwash until the water in the sight glass runs clear (typically 2-3 minutes).
  4. Éteignez la pompe.
  5. Set the valve to "RINSE".
  6. Mettez la pompe en marche et rincez pendant 30 à 60 secondes.
  7. Éteignez la pompe.
  8. Set the valve to "FILTER".
  9. Mettez la pompe en marche pour reprendre la filtration normale.

4.2. Hivernage (le cas échéant)

In colder climates, proper winterization is essential to prevent freeze damage.

  • Drain all water from the filter tank by opening the drain valve.
  • Remove the manometer and store it in a warm, dry place.
  • Set the multi-port valve handle between two positions (e.g., between "FILTER" and "CLOSED") to relieve pressure on the internal seal.
  • Disconnect all plumbing and store pipes if necessary.

5. Dépannage

This section addresses common issues you might encounter with your sand filter.

ProblèmeCause possibleSolution
Low water flow / High pressure gauge readingClogged filter media; dirty pump strainer basket; closed valve.Backwash the filter; clean pump strainer basket; ensure all valves are open.
Eau de piscine troubleInsufficient filtration time; dirty filter media; improper chemical balance; damaged internal components.Increase filtration time; backwash/rinse filter; check pool chemistry; inspect filter internals for damage.
Fuite d'eau au niveau de la vanneWorn O-rings or gaskets; loose clamp.Inspect and replace O-rings/gaskets; tighten clamp.
Le sable retourne à la piscineDamaged laterals inside filter; improper rinsing after backwash.Perform a thorough rinse cycle; inspect and replace damaged laterals.

6. Spécifications techniques

Detailed specifications for the Astralpool Aster 99- Sand Filter (Ø 500 model).

  • Modèle: Aster 99- Ø 500
  • Matériau de construction: Laminated Polyester and Fiberglass
  • Type de valve: Lateral Selector Valve
  • Accessoires inclus : Manometer, Drain Valve
  • Pression de service maximale: 2.5 kg/cm²
  • Maximum Filtration Capacity: 50 m³/h/m²

6.1. Dimensions (for Ø 500 model)

DimensionValeur (mm)
Ø (Diameter)500
D (Overall Diameter)500
H (hauteur)855
M (Valve Height from Base)415
N (Lower Port Height from Base)290
K (Port Size)1 1/2"

Note: Dimensions are approximate and subject to manufacturing tolerances. Refer to Figure 1 for visual representation of dimensions.

7. Informations sur la garantie

Specific warranty details for Astralpool products are typically provided at the point of purchase or within separate warranty documentation. Please retain your proof of purchase for any warranty claims. For detailed warranty terms and conditions, refer to the official Astralpool webconsultez votre site web ou contactez votre revendeur agréé.

8. Assistance clientèle

For technical assistance, spare parts, or further inquiries regarding your Astralpool Aster 99- Sand Filter, please contact your local Astralpool dealer or visit the official Astralpool website.

Astralpool Official Website: www.astralpool.com

© 2023 Astralpool. All rights reserved. Information in this manual is subject to change without notice.

Ask a question about this manual