PARADOX NV5W3C

Paradox NV5 High-Performance Infrared Motion Detector

Manuel d'utilisation

1. Introduction

The Paradox NV5 is a high-performance infrared motion detector designed for reliable security applications. This device offers advanced detection capabilities, false alarm immunity, and ease of installation, making it suitable for various indoor environments. This manual provides essential information for the proper setup, operation, and maintenance of your NV5 detector.

Paradox NV5 motion detector product image with brand logo.

Figure 1: Paradox NV5 Motion Detector Overview

2. Produit terminéview et fonctionnalités

The NV5 detector is engineered for superior performance and reliability. Key features include:

  • High-Performance Detection: Provides even detection with no dead zones within the protected range.
  • Réponse rapide : Quick response to both slow and fast movements.
  • False Alarm Immunity: Utilizes Paradox's Auto Pulse Signal Processing (APSP) and Dual/Single Edge Processing for enhanced stability.
  • Digital Temperature Compensation: Maintains consistent catch capability across specified operating temperatures.
  • Immunité RF: Designed to resist radio frequency interference.
  • Sensibilité personnalisable : Offers 5 levels of sensitivity to adapt to different environmental needs.
  • Pet Resistant: Designed to minimize false alarms caused by pets.
  • Adjustable Creep Zone: Enhanced creep zone sensitivity with an optional mirror add-on.
  • Installation facile : Designed for quick and straightforward setup without PC board removal.
Devant view of the Paradox NV5 High-Performance Infrared Motion Detector.

Figure 2 : Face avant View of NV5 Detector

Interne view of the Paradox NV5 motion detector circuit board, showing detection patterns for standard and pet-immune operation, and creep zone.

Figure 3: NV5 Internal Components and Detection Patterns

3. Configuration et installation

The NV5 detector is designed for simple and efficient installation. Follow these guidelines for optimal performance:

3.1 Emplacement de montage

Choose a mounting location that provides the best coverage of the protected area. The NV5 is designed for wall mount installation. Avoid placing the detector directly facing heat sources, windows, or areas with strong air currents that could cause false alarms.

3.2 Montage du détecteur

  1. Separate the front cover from the base of the detector.
  2. Mount the base securely to the wall using appropriate screws. An optional wall/ceiling mount bracket is available for flexible positioning.
  3. No PC board removal is necessary for installation; the PC board can be easily clipped in and out if desired for maintenance.

3.3 Câblage

The NV5 is a hardwired device and requires a corded electric power source. Connect the detector to your alarm system panel according to the panel's wiring diagram. The NV5 is compatible with EVO, Spectra, Magellan, and various 3rd party alarm systems. Ensure all connections are secure and correctly polarized.

3.4 Power-Up and Walk Test

After wiring, apply power to the detector. Allow a few minutes for the detector to stabilize. Perform a walk test to verify the detection coverage and ensure the detector triggers the alarm system when motion is detected within the protected area. Adjust the detector's position if necessary to optimize coverage.

4. Utilisation du détecteur

The NV5 detector operates automatically once installed and powered. Its advanced features ensure reliable motion detection.

4.1 Sensitivity Levels

The NV5 offers 5 levels of sensitivity. You can adjust the sensitivity to match the specific requirements of the protected area and minimize false alarms. Refer to the detector's internal settings or your alarm panel's manual for instructions on adjusting sensitivity.

4.2 Immunité des animaux de compagnie

The NV5 is designed with pet immunity to prevent false alarms from small animals. For optimal pet immunity, ensure the detector is mounted at the recommended height and the pet's movement does not exceed the specified immunity threshold. Consult the installation guide for specific pet immunity guidelines.

4.3 Creep Zone

The detector includes an adjustable creep zone, which covers the area directly beneath the detector. For enhanced creep zone sensitivity, especially in situations where an intruder might attempt to bypass the main detection pattern by staying low, a mirror add-on is available and recommended.

5. Entretien

Regular maintenance ensures the long-term reliability and performance of your NV5 motion detector.

  • Nettoyage: Periodically clean the detector's lens with a soft, dry cloth to remove dust or smudges that could obstruct its view. N'utilisez pas de nettoyants ou de solvants abrasifs.
  • Test de fonctionnalité : Conduct a walk test at least once a year to confirm the detector is functioning correctly and its coverage area remains effective.
  • Vérification du câblage : Inspect wiring connections periodically to ensure they are secure and free from corrosion.

6. Dépannage

If you encounter issues with your NV5 detector, consider the following troubleshooting steps:

ProblèmeCause possibleSolution
Pas de détection
  • Câblage incorrect
  • Perte de puissance
  • Obstrué view
  • Réglage de sensibilité incorrect
  • Check all wiring connections to the alarm panel.
  • Verify power supply to the detector.
  • Assurez-vous que la lentille est propre et dégagée.
  • Adjust sensitivity to a higher level.
Fausses alertes
  • Heat sources or air currents
  • Animaux de compagnie ou petits animaux
  • Réglage de sensibilité incorrect
  • Câblage desserré
  • Éloignez le détecteur des sources de chaleur ou des courants d'air.
  • Ensure pet immunity settings are appropriate; consider adjusting mounting height.
  • Reduce sensitivity if too high.
  • Vérifiez et sécurisez toutes les connexions de câblage.
Fonctionnement intermittent
  • Connexion de câblage desserrée
  • Fluctuations de puissance
  • Interférences RF
  • Inspectez et serrez toutes les connexions de câblage.
  • Assurer une alimentation électrique stable.
  • Check for nearby sources of strong RF signals.

If problems persist after attempting these solutions, contact Paradox technical support or a qualified security professional.

7. Spécifications

FonctionnalitéSpécification
Numéro de modèleNV5W3C
Numéro de pièceNV5W3C
Poids de l'article2.2 livres
Dimensions du produit1 x 1 x 1 pouces
Source d'énergieÉlectrique avec fil
Quantité du paquet d'articles1
Type de montageSupport mural
Piles inclusesNon
Piles requisesNon
CompatibilitéEVO, Spectra, Magellan, 3rd party alarm systems

8. Garantie et assistance

For information regarding the product warranty, please refer to the documentation provided with your purchase or visit the official Paradox website. For technical support, installation assistance, or any other inquiries, please contact Paradox customer service or your authorized dealer. Keep your purchase receipt and product model number (NV5W3C) handy when contacting support.

Paradox Official Website: www.paradox.com

© 2023 Paradox. Tous droits réservés.

Documents connexes - NV5W3C

Préview Détecteur de mouvement extérieur PIR Paradox PMD85 : installation et spécifications
Guide complet du détecteur de mouvement PIR numérique extérieur double optique haute performance Paradox PMD85, couvrant l'installation, les fonctionnalités, les paramètres, les spécifications techniques et les diagrammes de faisceau.
Préview Guide de programmation Digiplex EVO192 : Système de haute sécurité et de contrôle d’accès
Guide de programmation complet pour le système de haute sécurité et d'accès Paradox Digiplex EVO192 (V7.11), détaillant la configuration, la programmation des zones et les paramètres du système.
Préview PARADOX C702 & C706 Card Printing Instructions and Precautions
Detailed instructions and precautions for printing on PARADOX C702 Clam Shell and C706 2-sided High-Gloss ISO cards, including general information, handling, and image printing guidelines.
Préview Système de haute sécurité et de contrôle d'accès Paradox Digiplex EVO
Surview du système de haute sécurité et de contrôle d'accès Paradox Digiplex EVO, détaillant ses caractéristiques, système surview, et les spécifications des panneaux, claviers, détecteurs et modules.

Ask a question about this manual