Risco RK815DTG300B

RISCO RK815DTG300B Dual Technology Detector

Manuel d'utilisation

1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of the RISCO RK815DTG300B Dual Technology Detector. This device combines Passive Infrared (PIR) and Microwave (MW) detection technologies to offer reliable and accurate motion sensing for security applications. Please read this manual thoroughly before installation and use to ensure proper functionality and safety.

2. caractéristiques du produit

The RISCO RK815DTG300B detector is designed with advanced features to enhance security and minimize false alarms:

  • Dual Technology Detection: Combines dual-element PIR and 10.25 GHz Microwave for superior detection and false alarm immunity.
  • Anti-Cloak Technology (ACT) Green Line: Deactivates the microwave channel when the system is disarmed, reducing power consumption and extending product life.
  • Active Infrared Anti-Masking: Detects attempts to block the detector's field of view, providing enhanced tampeuh protection.
  • Selectable End-of-Line (EOL) Resistors: Configurable via jumpers for flexible wiring with various control panels.
  • Tampeuh Protection : Features anti-opening and anti-dismount (wall/angle) tamper switches to alert against unauthorized access or removal.
  • Adjustable Microwave Sensitivity: Allows fine-tuning of the microwave detection range.
  • Advanced Detection Zones: Provides 30 detection zones across 4 levels with anti-radiation features.
  • Indicateurs visuels : Equipped with 3 LED indicators for status and detection events.
  • True Temperature Compensation: Ensures consistent detection performance across varying ambient temperatures.
  • High Immunity: Excellent immunity to Radio Frequency (RF) interference and white light, reducing false alarms.

3. Consignes de sécurité

Veuillez respecter les consignes de sécurité suivantes :

  • L'installation doit être effectuée uniquement par du personnel qualifié, conformément aux codes et réglementations électriques locaux.
  • Coupez l'alimentation électrique avant toute opération de câblage ou de maintenance.
  • N’exposez pas l’appareil à l’humidité, aux températures extrêmes ou à la lumière directe du soleil.
  • Assurez-vous que la surface de montage est stable et sécurisée.
  • Gardez l’appareil à l’écart des champs électromagnétiques puissants.

4. Contenu du colis

Vérifiez que tous les éléments sont présents dans le colis :

  • RISCO RK815DTG300B Dual Technology Detector unit
  • Vis de montage et chevilles
  • Installation Guide / User Manual (this document)
  • Optional lenses (if purchased separately)

5. Configuration et installation

Une installation correcte est essentielle pour un fonctionnement optimal. Suivez attentivement ces étapes :

5.1 Emplacement de montage

Choose a mounting location that provides the best coverage of the protected area. Avoid placing the detector directly facing heat sources, windows, or areas with strong air currents. The ideal mounting height is typically 2.1 to 2.7 meters (7 to 9 feet) above the floor.

5.2 Ouverture du détecteur

Ouvrez soigneusement le détecteur casing par releasing the locking tab, usually located at the bottom or side of the unit. This will expose the terminal block and jumper settings.

5.3 Câblage

Connect the detector to the control panel according to the panel's instructions and the detector's terminal markings. Ensure correct polarity for power connections. Utilize the selectable EOL resistors via jumpers as required by your security system.

Connexions terminales :

  • + / - : Power input (typically 9-16 VDC).
  • ALARME: Normally Closed (NC) alarm output.
  • TAMPFR: Normalement fermé (NC) tamper sortie.
  • MASQUE: Anti-masking output (if used).

5.4 Paramètres des cavaliers

Configure the jumpers for EOL resistors, microwave sensitivity, and ACT Green Line functionality as needed for your specific installation.

5.5 Montage du détecteur

Secure the detector base to the wall or corner using the provided screws and anchors. Ensure the tamper switch is properly engaged with the mounting surface.

RISCO RK815DTG300B Dual Technology Detector mounted on a wall

Figure 1: RISCO RK815DTG300B Dual Technology Detector. This image shows the front view of the detector, typically mounted on a wall or in a corner, indicating its compact design and sensor window.

5.6 Test de marche

After installation, perform a walk test to verify the detection coverage. Walk through the protected area and observe the LED indicators to confirm proper detection. Adjust the microwave sensitivity if necessary.

6. Mode d'emploi

The RK815DTG300B detector operates automatically once powered and configured. It continuously monitors the protected area using both PIR and Microwave technologies.

6.1 Detection Logic

For an alarm to be triggered, both the PIR and Microwave sensors must detect motion simultaneously (AND logic), significantly reducing false alarms compared to single-technology detectors.

6.2 Indicateurs LED

The detector features three LEDs to indicate its status:

  • PIR LED: Illuminates when the PIR sensor detects motion.
  • MW LED: Illuminates when the Microwave sensor detects motion.
  • LED D'ALARME : Illuminates when both PIR and MW detect motion, triggering an alarm.

6.3 Anti-Cloak Technology (ACT) Green Line

When enabled, the ACT Green Line feature automatically deactivates the microwave sensor when the security system is disarmed. This conserves energy and extends the lifespan of the microwave component. The microwave sensor reactivates automatically when the system is armed.

7. Entretien

The RISCO RK815DTG300B detector requires minimal maintenance to ensure continued reliable operation.

  • Nettoyage: Nettoyez périodiquement la lentille et le c du détecteurasinNettoyez avec un chiffon doux et sec. N’utilisez pas de nettoyants abrasifs ni de solvants.
  • Inspection: Annually inspect the detector for any signs of damage, loose wiring, or obstructions to its field of view.
  • Test de marche : Perform a walk test periodically (e.g., every 6-12 months) to confirm the detector is functioning correctly.

8. Dépannage

If you experience issues with your detector, refer to the following common problems and solutions:

ProblèmeCause possibleSolution
Pas de détectionIncorrect wiring, power issue, obstructed view, incorrect sensitivity.Check wiring connections and power supply. Ensure no obstructions. Adjust microwave sensitivity. Perform a walk test.
Fausses alarmesHeat sources, air currents, pets, incorrect sensitivity, RF interference.Relocate detector away from heat/air sources. Adjust sensitivity. Ensure proper mounting height for pet immunity. Check for strong RF sources.
Tampeuh alarmeDetector cover open, unit dismounted, loose tampeuh interrupteur.Ensure the detector cover is securely closed. Verify the unit is firmly mounted and the tampl'interrupteur est engagé.
Anti-masking alarmObstruction in front of the detector, dirty lens.Clear any objects blocking the detector's view. Clean the lens.

If the problem persists, contact your security system installer or RISCO technical support.

9. Spécifications

FonctionnalitéDétail
ModèleRK815DTG300B
Technologie de détectionDual-element PIR + 10.25 GHz Microwave
Anti-MasquageInfrarouge actif
Tampeuh protectionAnti-opening and Anti-dismount (wall/angle)
Résistances de fin de ligneSelectable via jumpers
Zones de détection30 zones, 4 levels
Indicateurs visuels3 LEDs (PIR, MW, Alarm)
Compensation de températureTrue Temperature Compensation
ImmunitéHigh RF and White Light Immunity
FabricantRISCO
ASINB01N76MHTB
Code UPC712073721408

10. Garantie et assistance

For warranty information, please refer to the documentation provided with your purchase or visit the official RISCO Group website. For technical support, contact your authorized RISCO installer or the RISCO customer service department.

Groupe RISCO Website: www.riscogroup.com

© 2024 RISCO Group. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.