Technical Precision CE 2501 DEUTERIUM LAMP
Manuel d'utilisation
Replacement for CECIL Instruments CE 2501 DEUTERIUM LAMP Ampoule
Fabriqué par Précision technique
Produit terminéview
This document provides essential information for the safe and effective use of the Technical Precision Replacement for CECIL Instruments CE 2501 DEUTERIUM LAMP Light Bulb. This bulb is designed as a direct replacement for the original CECIL Instruments CE 2501 DEUTERIUM LAMP.

Image: The Technical Precision Replacement Deuterium Lamp, showing its tubular shape, clear casing, and attached electrical wires (red and blue) with connectors.
Précautions de sécurité
- Always disconnect power to the instrument before attempting installation or removal of the lamp.
- Autoriser le lamp to cool completely before handling. Hot lamppeuvent provoquer de graves brûlures.
- Manipulez le lamp by its base or wires; avoid touching the glass envelope directly, as oils from skin can reduce lamp vie.
- Portez un équipement de protection individuelle (EPI) approprié, tel que des gants et une protection oculaire, pendant l'installation.
- Jeter le vieux lamps according to local regulations for electronic waste.
Configuration et installation
- Ensure the CECIL Instruments CE 2501 device is powered off and unplugged from its power source.
- Localisez le lamp housing within the instrument. Refer to your instrument's specific service manual for precise location and access instructions.
- Carefully remove the old deuterium lamp. Note the orientation and connection of the wires.
- Unpack the new Technical Precision replacement lamp. Handle it by the base or wires to avoid touching the glass.
- Connectez les fils du nouveau lamp to the corresponding terminals in the instrument. Ensure correct polarity if indicated.
- Insérez délicatement le nouveau lamp into its housing, ensuring it is seated securely. Do not force the lamp en place.
- Fermez le lamp housing and reassemble any covers or panels removed during the process.
- Reconnect the instrument to its power source.
Mode d'emploi
Une fois le lamp is installed, the instrument can be powered on. The deuterium lamp typically requires a warm-up period to stabilize its light output. Refer to your CECIL Instruments CE 2501 user manual for specific warm-up times and calibration procedures.
- Power on the CECIL Instruments CE 2501 device.
- Allow the instrument to complete its self-test and lamp warm-up cycle. This may take several minutes.
- Perform any necessary lamp alignment or calibration procedures as outlined in your instrument's manual to ensure optimal performance.
- Moniteur lamp intensity and stability as part of routine instrument checks.
Entretien
The Technical Precision replacement lamp is designed for long life and stable performance. Regular maintenance primarily involves monitoring its output and replacing it when its intensity diminishes or it fails to ignite.
- Lamp Life Monitoring: Keep a record of the lamp's operating hours. Deuterium lamps have a finite lifespan, and performance degrades over time.
- Nettoyage: Le lamp itself generally does not require cleaning. If the glass envelope appears smudged, gently wipe it with a lint-free cloth and isopropyl alcohol, ensuring no residue remains. Always ensure the lamp is cool and power is disconnected before cleaning.
- Stockage: Stockez les pièces de rechange lamps dans leur emballage d'origine, dans un endroit frais et sec, à l'abri de la lumière directe du soleil et des températures extrêmes.
Dépannage
| Problème | Cause possible | Solution |
|---|---|---|
| Lamp ne s'enflamme pas. |
|
|
| Low or unstable light output. |
|
|
Note: For complex issues or instrument-specific problems, always refer to the original CECIL Instruments CE 2501 service manual or contact a qualified service technician.
Caractéristiques
| Attribut | Valeur |
|---|---|
| Marque | Précision technique |
| Numéro de modèle | CE 2501 DEUTERIUM LAMP |
| Quoitage | 16 watts |
| Nombre d'unités | 1.0 Nombre |
| Nombre d'articles | 1 |
| Forme | Tubular(T) |
| Matériel | cuivre |
| Technologie de connectivité | Ampoule normale |
| Fabricant | Précision technique |
| ASIN | B01MDLM003 |
| Date de première disponibilité | 12 octobre 2016 |
Garantie et assistance
For specific warranty information regarding this Technical Precision replacement lamp, please refer to the documentation provided with your purchase or contact Technical Precision directly. As this is a replacement part, its warranty may differ from the original instrument's warranty.
For technical support or inquiries, please contact Technical Precision through their official channels. You can often find contact information on their official websur le site ou auprès du détaillant où le produit a été acheté.
Fabricant: Précision technique
Boutique en ligne: Technical Precision Amazon Store