1. Introduction

This manual provides essential information for the safe and effective use of your GIMA London Aneroid Sphygmomanometer, Model 32725. Please read these instructions carefully before use and retain them for future reference. This device is designed for professional and personal use to measure blood pressure.

Informations importantes sur la sécurité :

  • Consultez un professionnel de la santé pour l'interprétation de vos mesures de tension artérielle. L'autodiagnostic et l'automédication basés sur ces mesures peuvent être dangereux.
  • Do not use this device on infants or individuals unable to communicate.
  • Gardez l’appareil à l’abri de l’eau et des températures extrêmes.
  • Regular calibration checks are recommended to ensure accuracy.
GIMA London Aneroid Sphygmomanometer, black cuff and manometer

Image 1.1: The GIMA London Aneroid Sphygmomanometer with its black cuff and manometer.

2. Composants du produit

The GIMA London Aneroid Sphygmomanometer consists of the following main components:

  • Manomètre: A 55 mm diameter dial with vivid colors for easy reading, protected by a plastic ring. It features a high-quality precision mechanism.
  • Manchette: A calibrated nylon cuff with a Velcro closure, designed for adult use.
  • Vessie: A single-tube TPU bladder integrated within the cuff.
  • Ampoule de gonflage : An integrated PVC bulb for inflating the cuff, designed to be latex-free.
  • Soupape de purge d'air : A screw-type valve for controlled deflation.
  • Mallette de transport : An elegant matching nylon case for storage and transport.
Components of the GIMA London Sphygmomanometer: cuff, manometer, and inflation bulb

Image 2.1: Individual components of the sphygmomanometer, including the cuff, manometer, and inflation bulb.

Person having blood pressure taken with GIMA sphygmomanometer, highlighting reliable, lightweight, latex-free, and integrated PVC bulb features

Image 2.2: The device is reliable, lightweight, latex-free, and features an integrated PVC bulb.

3. Installation

Follow these steps to prepare your sphygmomanometer for use:

  1. Déballer: Retirez soigneusement tous les composants de l'étui de transport.
  2. Connect Cuff and Manometer: Ensure the air tube from the cuff is securely connected to the manometer.
  3. Connect Bulb: Attach the inflation bulb to the air tube leading to the cuff. The connections should be snug to prevent air leakage.
Two GIMA aneroid sphygmomanometers, one black and one red, shown with their matching nylon cases

Image 3.1: The sphygmomanometer is available in black (NERO) and red, each equipped with an elegant matching nylon case.

4. Mode d'emploi

For accurate blood pressure measurement, follow these guidelines:

  1. Positionnement du patient : The measurement should be performed under conditions of both physical and mental relaxation. The patient should be in a sitting or supine position. Where possible, take measurements at the same time of day, away from meal times.
  2. Placement du brassard : Wrap the cuff firmly around the upper arm, approximately 2-3 cm above the elbow joint, ensuring the artery mark on the cuff aligns with the brachial artery. The cuff should be snug but not overly tight.
  3. Inflation: Close the air release valve by turning it clockwise. Rapidly inflate the cuff by squeezing the inflation bulb until the manometer reads approximately 20-30 mmHg above the expected systolic pressure.
  4. Déflation et lecture : Slowly open the air release valve by turning it counter-clockwise, allowing the pressure to drop at a rate of 2-3 mmHg per second. Listen for Korotkoff sounds with a stethoscope (not included). The first sound heard indicates systolic pressure, and the disappearance of sounds indicates diastolic pressure.
  5. Lectures enregistrées : Note down the systolic and diastolic pressure readings.
Healthcare professional taking blood pressure with GIMA sphygmomanometer, showing high quality precision mechanism and calibrated nylon cuff

Image 4.1: The device features a high-quality precision mechanism and a calibrated nylon cuff with Velcro closure and a single-tube TPU bladder.

Close-up of the 55mm diameter manometer dial with vivid, easy-to-read colors

Image 4.2: The 55 mm diameter dial features vivid, eye-catching colors for easy reading.

Doctor taking patient's blood pressure, showing the manometer protected by a special outer ring

Image 4.3: A special outer ring protects the manometer from shocks and the glass from scratches.

Recommended use for blood pressure measurement: patient in relaxed sitting or supine position

Image 4.4: Recommended use involves performing measurements under conditions of physical and mental relaxation, in a sitting or supine position, ideally at the same time each day and away from meal times.

5. Entretien

Proper maintenance ensures the longevity and accuracy of your device:

  • Nettoyage: Wipe the cuff and manometer with a soft, damp Nettoyez avec un chiffon. N’utilisez pas de nettoyants abrasifs et n’immergez aucune partie de l’appareil dans l’eau.
  • Stockage: Store the sphygmomanometer in its protective nylon case when not in use. Keep it in a cool, dry place, away from direct sunlight, dust, and extreme temperatures.
  • Étalonnage: Aneroid sphygmomanometers should be professionally calibrated periodically (e.g., every 1-2 years) to ensure continued accuracy. Consult a qualified technician for calibration services.

6. Dépannage

Si vous rencontrez des problèmes avec votre appareil, reportez-vous aux problèmes courants et aux solutions suivants :

  • Cuff not inflating:
    • Ensure all connections (cuff to manometer, bulb to cuff) are secure.
    • Check that the air release valve is fully closed (turned clockwise).
    • Inspect the cuff and bladder for any punctures or leaks.
  • Lectures inexactes :
    • Verify correct cuff size and placement on the arm.
    • Ensure the patient is relaxed and positioned correctly.
    • Check for proper deflation rate (2-3 mmHg per second).
    • Consider professional calibration if readings consistently seem incorrect.
  • Fuite d'air:
    • Serrez toutes les connexions.
    • Inspect the inflation bulb, air tubes, and cuff bladder for cracks or holes.
    • Ensure the air release valve is fully closed.

If problems persist, contact GIMA customer support or a qualified service technician.

7. Spécifications

FabricantGIMA
Numéro de modèle32725
Dimensions du produit (L x l x H)15 x 7 x 24 cm
Poids du produit330 grammes
Cuff ColorNÉRO (Noir)
Diamètre du cadran55 mm
Sans latexOui
Piles requisesNon
ASINB00F378EJO
Date de première disponibilité sur Amazon.com.be12 mai 2022
Disponibilité des pièces de rechangeInformation indisponible

8. Garantie et assistance

For warranty information, please refer to the documentation provided with your purchase or contact GIMA customer service directly. GIMA is committed to providing reliable products and support.

If you require technical assistance, have questions about your device, or need to arrange for service, please contact GIMA customer support through their official website ou les coordonnées fournies dans l'emballage de votre produit.

For more information, visit the official GIMA website: www.gimaitaly.com

© 2024 GIMA. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.