Paradoxe SP5500

Paradox Spectra SP5500 Control Panel User Manual

Modèle: SP5500 | Marque: Paradoxe

Introduction

This manual provides comprehensive instructions for the installation, operation, and maintenance of the Paradox Spectra SP5500 wired control panel. The SP5500 is a robust security solution featuring 5 on-board zones, expandable up to 32 zones, 2 programmable outputs (PGMs), support for 2 partitions, and up to 32 user codes. It includes an integrated Contact ID protocol transmitter and supports remote programming via WinLoad software. This guide is intended to assist qualified installers and end-users in understanding and utilizing the system effectively.

Configuration et installation

Installation of the Paradox Spectra SP5500 control panel should be performed by a qualified security professional. Incorrect installation can lead to system malfunction or compromise security. Ensure all local electrical codes and safety regulations are followed.

1. Déballage et inspection

  • Retirez soigneusement tous les composants de l'emballage.
  • Vérifiez que tous les articles mentionnés sur le bon de livraison sont présents.
  • Inspect the control panel and other components for any signs of physical damage.

2. Montage du panneau de commande

Select a secure, dry, and easily accessible location for the control panel enclosure, typically in a utility closet or basement. Ensure the location is not exposed to extreme temperatures or moisture.

  • Fixez solidement le boîtier au mur à l'aide des fixations appropriées.
  • Prévoir un espace suffisant pour le câblage et la maintenance future.

3. Connexions de câblage

Reportez-vous au schéma ci-dessous pour un aperçu.view of the control panel's circuit board and terminal connections. All wiring should be performed with the main power supply disconnected.

Paradox Spectra SP5500 Control Panel Circuit Board with dimensions

Figure 1 : Surview of the Paradox Spectra SP5500 control panel circuit board, showing various components, terminals, and dimensions (10.8 cm / 4.25 inches height, 20.3 cm / 8 inches width). This image illustrates the layout for wiring connections.

  • Connexion électrique : Connect the AC transformer to the designated AC terminals. Ensure the transformer is rated correctly for the system.
  • Batterie de secours: Connect a rechargeable 12V backup battery to the battery terminals. This battery provides power during AC failures.
  • Câblage de zone : Connect detection devices (e.g., motion sensors, door/window contacts) to the numbered zone terminals. Each zone requires proper end-of-line resistor termination.
  • Connexion clavier : Connect keypads to the data bus terminals (typically labeled RED, BLK, GRN, YEL).
  • Sorties PGM : Utilize the Programmable Gate Module (PGM) outputs for controlling external devices such as sirens, strobes, or access control components.
  • Communication: Connect to a telephone line for Contact ID reporting if required.

4. Mise sous tension et programmation initiales

After all wiring is complete and verified, connect the AC power. The system will perform an initial self-test. Refer to the detailed programming guide for configuring zones, user codes, system options, and communication settings. Remote programming can be performed using Paradox WinLoad software.

Mode d'emploi

This section covers basic user operations. For advanced features, consult the full user manual or your installer.

1. Armement du système

  • Rester armé : Appuyez sur le [STAY] button, then enter your 4-digit user code. This arms the perimeter zones while allowing movement within the protected area.
  • Armement absent : Appuyez sur le [BRAS] button, then enter your 4-digit user code. This arms all zones, including interior motion detectors. Exit the premises within the programmed exit delay time.
  • Force Arming: If a zone is open, some systems allow force arming. Consult your installer for this feature.

2. Désarmement du système

To disarm the system, enter your 4-digit user code. This will silence any alarms and disarm all armed zones.

3. Bypassing Zones

To temporarily disable a specific zone (e.g., for an open window), press the [BYP] button, enter your user code, then enter the 2-digit zone number(s) to bypass. Press [ENTRER] to confirm. Bypassed zones are automatically unbypassed when the system is disarmed.

4. Modification des codes utilisateur

Consult your installer or the detailed programming manual for instructions on how to add, delete, or change user codes. This typically involves entering a master code followed by specific programming commands.

Entretien

Regular maintenance ensures the optimal performance and reliability of your security system.

  • Vérification de la batterie : The system's backup battery should be checked annually by a qualified technician. Replace the battery every 3-5 years, or as recommended by the manufacturer, to ensure proper operation during power outaget.
  • Test du système : Periodically test your alarm system (e.g., monthly) by arming it and triggering a zone. Inform your monitoring station (if applicable) before testing to avoid false dispatches.
  • Nettoyage: Keep the control panel and keypads clean and free of dust. Use a soft, dry cloth. Avoid abrasive cleaners or solvents.
  • Inspection du capteur : Visually inspect all sensors (motion detectors, door/window contacts) for any obstructions or damage.

Dépannage

This section addresses common issues. For complex problems, contact your security system installer or Paradox technical support.

  • Système non armé :
    • Check if any zones are open (e.g., door/window ajar). Close all zones or bypass the open zone.
    • Ensure the system is not displaying a trouble condition.
  • Trouble Light On:
    • Appuyez sur le [TROUBLE] button on your keypad to view the specific trouble condition (e.g., AC failure, battery low, communication failure).
    • Address the indicated issue. For AC failure, check the power supply. For low battery, consider battery replacement.
  • Fausses alarmes :
    • Identify the zone that triggered the alarm.
    • Check for environmental factors (e.g., drafts, pets, loose objects) affecting motion detectors.
    • Inspect sensors for damage or improper installation.
  • Le clavier ne répond pas :
    • Check power to the control panel.
    • Ensure keypad wiring is secure.

Caractéristiques

FonctionnalitéDétail
FabricantParadoxe
Numéro de modèleSP5500 (3700774000387)
Dimensions (Produit)28 x 26 x 10 cm (environ 11 x 10.2 x 3.9 pouces)
Poids de l'article3 kilogramme (environ 6.6 lb)
On-board Zones5
Zones extensiblesJusqu'à 32
Sorties PGM2
Cloisons2
Codes d'utilisateurJusqu'à 32
Protocole de communicationIntegrated Contact ID transmitter
Programmation à distanceSupported via WinLoad software
Piles inclusesNo (requires separate backup battery)
Première date disponible11 février 2015

Informations sur la garantie

Paradox products are typically covered by a limited manufacturer's warranty against defects in materials and workmanship. The specific terms and duration of the warranty may vary by region and product. Please retain your proof of purchase. For detailed warranty information, refer to the documentation provided with your product or contact your authorized Paradox dealer or installer.

Soutien

For technical assistance, advanced programming, or troubleshooting beyond the scope of this manual, please contact your authorized Paradox security system installer. They possess the expertise and tools necessary to provide comprehensive support for your SP5500 control panel. You may also visit the official Paradox website for additional resources, FAQs, and contact information for regional support.

Documents connexes - SP5500

Préview Paradox PS45 75W Supervised Backup Power Supply Installation Manual
Installation and programming guide for the Paradox PS45 75W supervised backup power supply. Includes wiring instructions, LED status indicators, and technical specifications.
Préview Paradox PS25 Supervised Bus Power Supply Installation Manual
Detailed installation manual for the Paradox PS25 supervised bus power supply, covering EVO, MG, and SP alarm panels. Includes compatibility, connections, programming, and technical specifications.
Préview Détails sur Paradox Magellan & Spectra SP
Comment utiliser votre appareil Utilisez Paradox Magellan pour Spectra SP, et utilisez le Paradox Magellan pour Spectra SP. προηγμένες λειτουργίες.
Préview Paradox Magellan et Spectra Series : Manuel de référence et d'installation
Guide de référence et d'installation complet pour les centrales d'alarme des séries Paradox Magellan et Spectra, couvrant les fonctionnalités, les spécifications, la programmation et le dépannage pour les installateurs.
Préview Guide de programmation SP5500+/SP6000+/SP7000+
Un guide de programmation complet pour les systèmes de sécurité extensibles Paradox série SP+, couvrant l'installation, la configuration et les fonctionnalités avancées des modèles SP5500+, SP6000+ et SP7000+.
Préview Guide d'utilisation Paradox SP5500+/SP6000+/SP7000+
Guide d'utilisation complet des systèmes de sécurité extensibles Paradox SP5500+, SP6000+ et SP7000+. Découvrez l'installation, la programmation, les fonctionnalités et le fonctionnement.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.