1. Introduction
The AmScope D120A-MS is a dual-view compound monocular microscope designed for high magnification observation in biological and educational applications. It features a versatile viewing head, multiple objective lenses, Brightfield illumination, and a mechanical stage for precise specimen manipulation. This manual provides essential information for the proper setup, operation, and maintenance of your microscope.
2. Consignes de sécurité
- Always handle the microscope with care. Avoid sudden movements or impacts.
- Veillez à placer le microscope sur une surface stable et plane afin d'éviter qu'il ne bascule.
- Connect the power cord to a grounded electrical outlet of the correct voltage (110 V).
- Do not touch optical surfaces with bare hands. Use lens paper or a soft, lint-free cloth for cleaning.
- Unplug the microscope from the power source before cleaning or performing any maintenance.
- Conservez le microscope à l'abri de la lumière directe du soleil, des températures élevées, de la poussière et des produits chimiques corrosifs.
- Supervise children or inexperienced users to ensure safe operation.
3. Contenu du colis
Déballez soigneusement tous les composants et vérifiez que les éléments suivants sont inclus :
- AmScope D120A-MS microscope with mechanical stage
- WF10x eyepiece
- WF16x eyepiece
- 4x DIN achromatic objective
- 10x DIN achromatic objective
- 40xS DIN achromatic objective (spring-loaded)
- 100xS (oil) DIN achromatic objective (spring-loaded)
- (2) Color filters
- Ampoule de rechange
- Cache-poussière
- Manuel d'instructions (ce document)
4. Identification des composants
Familiarize yourself with the main parts of your AmScope D120A-MS microscope:

Figure 4.1 : Surview of the AmScope D120A-MS microscope. This image displays the complete microscope assembly, including the base, stage, objective lenses, and dual-view monocular head.
- Oculaire : Là où vous regardez view the specimen. The D120A-MS includes WF10x and WF16x eyepieces.
- Monoculaire ViewChef d'entreprise : The upper part of the microscope containing the eyepiece tube. This model features a dual-view head with a fixed 45-degree inclined tube and a vertical port.
- Embout nasal rotatif : Holds the objective lenses and allows for easy switching between magnifications.
- Objectifs : The primary magnification components (4x, 10x, 40xS, 100xS oil).
- Mécanique Stage: A platform where the specimen slide is placed, with controls for precise X-Y movement.
- Stage Clips : Secure the specimen slide on the mechanical stage.
- Coarse Focus Knob: Large knob for rapid focusing adjustments.
- Fine Focus Knob: Small knob for precise focusing adjustments.
- Illuminator (Light Source): Situé sous le stage, provides light for viewing. This model uses variable-intensity tungsten illumination.
- Condensateur d'Abbe : Located below the stage, focuses light onto the specimen. Features a 1.25 NA and an iris diaphragm.
- Diaphragme à iris: Controls the amount of light passing through the specimen.
- Base: The stable bottom support of the microscope.
5. Assemblage et configuration
Follow these steps to set up your microscope for initial use:
- Déballage: Retirez délicatement le microscope et tous ses accessoires de leur emballage. Conservez l'emballage d'origine pour tout transport ou stockage ultérieur.
- Placement: Place the microscope on a sturdy, level surface, away from vibrations and direct sunlight.
- Installation de l'oculaire : Insert the desired eyepiece (WF10x or WF16x) into the inclined eyepiece tube of the monocular head. Gently twist to secure it.
- Objective Installation: The objective lenses are typically pre-installed. If not, carefully screw each objective into the revolving nosepiece in increasing order of magnification (4x, 10x, 40xS, 100xS). Ensure they are finger-tight.
- Connexion électrique : Connect the power cord to the microscope's power input and then to a standard 110V electrical outlet.
- Cache-poussière : When not in use, cover the microscope with the provided dust cover to protect it from dust and debris.

Figure 5.1 : Gros plan view of the objective lenses mounted on the revolving nosepiece. This image shows the 4x, 10x, 40xS, and 100xS (oil) objectives in position.
6. Fonctionnement de base
This section outlines the fundamental steps for observing specimens with your microscope.
- Mise sous tension : Flip the power switch located on the base of the microscope. The illuminator should light up.
- Ajuster l'éclairage : Use the variable intensity control knob to set the desired brightness. Adjust the iris diaphragm on the Abbe condenser to optimize contrast and resolution for your specimen.
- Spécimen de l'emplacement : Rotate the revolving nosepiece to select the lowest power objective (4x). Lower the mechanical stage using the coarse focus knob. Place a prepared specimen slide onto the mechanical stage et fixez-le avec le staget des clips.
- Position Specimen: Utilisez les XYtage control knobs to move the slide until the area of interest is centered under the objective lens.
- Mise au point :
- While looking through the eyepiece, slowly raise the stage en utilisant le molette de mise au point grossière until the specimen comes into rough focus.
- Utilisez le molette de mise au point fine to achieve a sharp, clear image.
- Modifier le grossissement : Once focused at low power, rotate the revolving nosepiece to switch to a higher power objective (e.g., 10x, 40xS). Due to the parfocal design, only minor adjustments with the fine focus knob should be needed to bring the image back into sharp focus.
- Utilisation de l'objectif à immersion dans l'huile 100xS :
- Après avoir effectué la mise au point avec l'objectif 40xS, faites pivoter le porte-objectifs à mi-chemin entre les objectifs 40xS et 100xS.
- Place a small drop of immersion oil directly onto the center of the specimen slide where the light passes through.
- Carefully rotate the 100xS objective into the oil drop until it clicks into place. The objective should be immersed in the oil.
- Utilisez uniquement le molette de mise au point fine to bring the image into sharp focus. Do not use the coarse focus knob with the 100xS objective.
- After use, clean the 100xS objective and the slide immediately with lens paper moistened with lens cleaning solution to remove all immersion oil.
- Double-View Fonctionnalité: The vertical port on the monocular head can accept a second eyepiece for simultaneous viewing by another person or a camera mount for digital image capture (eyepiece and camera sold separately). Dioptric adjustment on the upright tube accommodates individual eye-strength differences.

Figure 6.1 : The AmScope D120A-MS microscope demonstrating its digital image capture capability by connecting to a laptop. This setup utilizes the vertical port for a camera attachment.
7. Maintenance et entretien
Proper maintenance ensures the longevity and optimal performance of your microscope.
- Nettoyage des lentilles : Use only specialized lens paper and lens cleaning solution for optical surfaces. Gently wipe in a circular motion. Never use abrasive cloths or harsh chemicals.
- Nettoyage général : Essuyez le corps du microscope avec un chiffon doux et sec.amp cloth. Avoid getting moisture into electrical components.
- Stockage: Always cover the microscope with the dust cover when not in use. Store it in a dry, dust-free environment.
- Remplacement de l'ampoule : If the illuminator bulb burns out, unplug the microscope. Refer to the base of the microscope for access to the bulb compartment. Carefully replace the old bulb with the provided spare bulb, ensuring not to touch the glass part of the new bulb with bare hands.
- Pièces mécaniques : Do not attempt to lubricate or disassemble any mechanical parts. If issues arise, contact customer support.
8. Dépannage
Cette section aborde les problèmes courants que vous pourriez rencontrer.
| Problème | Cause possible | Solution |
|---|---|---|
| Pas d'éclairage | Power cord disconnected, power switch off, bulb burnt out | Check power connection, turn on switch, replace bulb |
| L'image est floue ou hors de la mise au point | Incorrect focus adjustment, objective not fully engaged, dirty lens | Adjust coarse/fine focus, rotate nosepiece until objective clicks, clean lenses |
| Champ sombre de view | Iris diaphragm closed, illuminator too dim, condenser too low | Open iris diaphragm, increase illuminator brightness, adjust condenser height |
| Poussière ou taches dans view | Dust on eyepiece, objective, or slide | Clean eyepiece, objective, or slide with lens paper |
| Cannot focus at 100x | No immersion oil, air bubbles in oil, coarse focus used | Apply immersion oil, remove air bubbles, use only fine focus |
9. Spécifications techniques
Detailed specifications for the AmScope D120A-MS microscope:
- Tête: Compound dual-view monocular, 45-degree inclined, 360-degree rotatable
- Oculaires : WF10x, WF16x (with pointer)
- Objectifs : 4X, 10x, 40xS (spring), 100xS (oil, spring) DIN achromatic
- Plage de grossissement : 40X - 1600X
- Stage: Mécanique stage with X-Y axis movement, staget arrêtez
- Configuration d'éclairage : Transmitted (lower)
- Condenseur: Abbe, 1.25 NA
- Diaphragme: Diaphragme à iris
- Source de lumière : Tungsten (incandescent), variable intensity
- Type d'éclairage : Champ lumineux
- Pouvoir: 110V
- Matériel: Metal, tungsten
- Dimensions (H x L x P) : 15 x 7.5 x 5.125 pouces (environ)
- Poids: 10 livres
10. Garantie et support client
For warranty information, technical assistance, or to purchase replacement parts, please contact AmScope customer support. Refer to the AmScope webPour obtenir nos coordonnées actuelles, veuillez consulter notre site web ou vos documents d'achat.