Introduction
The Sure-Lites LPX7 Series LED Exit Light is a universal emergency exit sign designed for general purpose applications. This unit features a durable polycarbonate housing and is equipped with LED lamps, offering energy efficiency and reliability. It supports dual voltage input (120/277 VAC) and includes a nickel cadmium battery for emergency operation, providing a minimum run time of 90 minutes during power loss.
The LPX7 series is engineered for ease of installation and maintenance, making it a suitable replacement for previous models like the CCX Series. It ships with components to configure either red or green exit legends, providing flexibility for various installation requirements.

Figure 1: Sure-Lites LPX7 Universal Emergency Exit Light with red legend illuminated.
Consignes de sécurité
Veuillez lire et comprendre toutes les instructions avant d'installer ou d'utiliser ce produit. Le non-respect de ces instructions peut entraîner un choc électrique, un incendie ou d'autres dangers susceptibles de causer des dommages matériels ou des blessures.
- Coupez toujours l'alimentation au niveau du disjoncteur avant toute installation ou intervention.
- Assurez-vous que tous les raccordements électriques sont conformes aux codes, ordonnances et au Code national de l'électricité (NEC) locaux.
- Ne pas monter à proximité de radiateurs à gaz ou électriques.
- Do not allow power supply cords to be pinched or damaged.
- L'entretien doit être effectué uniquement par un personnel d'entretien qualifié.
- Do not use outdoors. This unit is designed for indoor use only.
- The battery in this unit is a Nickel Cadmium (NiCAD) battery. Dispose of batteries properly according to local regulations.
Contenu du colis
Vérifiez que tous les composants sont présents et non endommagés avant de commencer l'installation :
- LPX7 Emergency Exit Sign Unit
- Kit de matériel de montage
- Configurable Red and Green Lettering Inserts
- Instructions d'installation (ce manuel)
Configuration et installation
The LPX7 exit sign is designed for universal mounting, allowing for ceiling, wall, or end mount installations. Follow these steps for proper setup:
1. Sélection du site
Choose a mounting location that is visible and meets local building codes for emergency exit signage. Ensure the mounting surface is structurally sound to support the unit's weight.
2. Déconnexion de l'alimentation
Before starting any electrical work, turn off power to the circuit at the main breaker panel to prevent electric shock.
3. Préparation du montage
Determine the desired mounting method (ceiling, wall, or end mount). The unit is designed for semi-flush mount installation. Refer to the dimensions diagram for precise measurements.

Figure 2: Dimensional drawing of the LPX7 exit light, showing overall width of 13 inches (330mm), overall height of 7 1/2 inches (190mm), and overall depth of 2 1/8 inches (54mm).
4. Connexion électrique
Connect the unit to a 120 VAC or 277 VAC, 60 Hz power source. The LPX7 features dual voltage input. Ensure proper wiring according to the provided wiring diagram (typically found inside the unit or on a separate sheet). All connections must be secure and insulated.
5. Connexion de la batterie
Connect the internal Nickel Cadmium (NiCAD) battery. The battery is typically pre-installed but may require connecting a small plug to the circuit board. Ensure the connection is firm.
6. Legend Configuration
Insert the desired red or green legend panels into the unit. The LPX7 ships with both options, allowing for field configuration.
7. Assemblage final
Secure the unit to the mounting surface using the provided hardware. Ensure the housing is properly closed and secured.
8. Power Restoration & Testing
Restore power to the circuit. The exit sign should illuminate. Press the "TEST" button (usually a small push-button on the side or bottom of the unit) to verify emergency operation. The unit should switch to battery power and remain illuminated for at least 30 seconds. Release the button, and the unit should return to AC power.
Opération
The Sure-Lites LPX7 Emergency Exit Light operates automatically. When connected to a continuous AC power source, the LED lamps will remain illuminated, indicating the exit path. The internal Nickel Cadmium battery continuously charges while AC power is present.
Mode d'urgence
En cas de panne de couranttage or interruption to the AC supply, the unit will automatically switch to emergency mode, drawing power from its internal battery. The LED lamps will remain illuminated for a minimum of 90 minutes, providing essential egress lighting.
Bouton de test
A test button is provided on the unit for routine maintenance checks. Pressing and holding this button simulates a power failure, allowing you to verify that the battery and lamps are functioning correctly in emergency mode. Release the button to return to normal AC operation.

Figure 3 : Example installation of an emergency exit light in a commercial waiting area, demonstrating its function in a public space.

Figure 4 : Example installation of an emergency exit light in an auditorium, highlighting its visibility in a large gathering space.
Entretien
Regular maintenance ensures the continued reliable operation of your emergency exit light. Always disconnect power before performing any maintenance.
Tests mensuels
Perform a monthly 30-second test by pressing the test button. The unit should operate on battery power for the duration of the test. If the lamps do not illuminate or dim significantly, the battery may need replacement or further charging.
Tests annuels
Conduct an annual 90-minute discharge test. Disconnect AC power to the unit and allow it to operate on battery power for 90 minutes. The lamps should remain illuminated for the entire duration. If the unit fails to operate for 90 minutes, the battery requires replacement.
Nettoyage
Nettoyez périodiquement l'extérieur de l'appareil avec un chiffon doux et sec.amp cloth. Do not use abrasive cleaners or solvents, as these can damage the polycarbonate housing.
Remplacement de la batterie
The Nickel Cadmium battery has a typical lifespan of 5-7 years. If the unit fails to meet the required emergency run time during testing, replace the battery with an approved Sure-Lites replacement battery. Ensure proper polarity when connecting the new battery.
Dépannage
If your Sure-Lites LPX7 Emergency Exit Light is not functioning as expected, refer to the following common issues and solutions:
| Problème | Cause possible | Solution |
|---|---|---|
| Unit does not illuminate when AC power is on. | No AC power to the unit; Loose wiring connection; Faulty LED lamps. | Check circuit breaker and power supply. Verify all wiring connections are secure. Contact qualified service personnel if lamps sont défectueux. |
| Unit does not illuminate in emergency mode (during test or power outaget). | Battery not connected; Battery not charged; Battery has reached end of life; Faulty circuit board. | Ensure battery is properly connected. Allow 24 hours for initial battery charge. Replace battery if it fails annual test. Contact qualified service personnel. |
| Lamps are dim in emergency mode. | Batterie non complètement chargée ; batterie en fin de vie. | Allow unit to charge for 24 hours. If problem persists, replace battery. |
If the problem persists after attempting these solutions, contact Sure-Lites customer support or a qualified electrician.
Caractéristiques
| Fonctionnalité | Détail |
|---|---|
| Numéro de modèle | LPX7 |
| Vol d'entréetage | 120/277 VCA, 60 Hz |
| Source de lumière | LED (2 Lamps) |
| Température de couleur | 5000K |
| Legend Color | Configurable Red or Green |
| Legend Height | 6 pouces |
| Type de montage | Universal (Ceiling, Wall, End Mount) |
| Matériau du boîtier | Polycarbonate |
| Couleur du boîtier | Blanc |
| Type de batterie | Nickel Cadmium (NiCAD) |
| Durée de fonctionnement d'urgence | 90 min minimum |
| Hauteur totale | 7.5 pouces (190 mm) |
| Largeur hors tout | 13 pouces (330 mm) |
| Profondeur totale | 2.125 pouces (54 mm) |
| Poids de l'article | 2.88 livres |
Garantie et assistance
Informations sur la garantie
The Sure-Lites LPX7 Emergency Exit Light comes with a Garantie de 5 ans from the date of purchase. This warranty covers defects in materials and workmanship under normal use and service. The warranty does not cover damage resulting from improper installation, misuse, abuse, or acts of nature.
Assistance clientèle
For technical assistance, warranty claims, or replacement parts, please contact Sure-Lites customer support. Refer to the Sure-Lites official webPour obtenir les coordonnées les plus récentes, veuillez consulter le site web ou l'emballage du produit.
Note: Always provide your product model number (LPX7) and date of purchase when contacting support to expedite assistance.